Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Transl Vis Sci Technol ; 10(6): 28, 2021 05 03.
Article in English | MEDLINE | ID: mdl-34019635

ABSTRACT

Purpose: To assess the structure-function relationship in glaucoma using Humphrey visual field (HVF) perimetry and a three-dimensional neuroretinal rim parameter derived from spectral domain optical coherence tomography (SD-OCT) volume scans. Methods: Structure-function correlation was analyzed globally and regionally (four quadrants and four sectors). Structural data included peripapillary retinal nerve fiber layer (RNFL) thickness and minimum distance band (MDB) neuroretinal rim thickness, defined as the shortest distance between the inner cup surface and the outer retinal pigment epithelium/Bruch's membrane complex. Logarithmic regression analyses were performed and Pearson correlation coefficients determined to assess relationship strength. Results: The study consisted of 102 open-angle glaucoma patients and 58 healthy subjects. The Pearson correlation coefficient for global MDB thickness (R = 0.585) was higher than for global RNFL thickness (R = 0.492), but the difference was not statistically significant (P = 0.18). The correlation coefficients for regional MDB thicknesses and corresponding HVF sensitivities were higher than those for regional RNFL thicknesses and HVF in six out of eight regions (P = 0.08 to 0.47). In the remaining two out of eight regions, the correlation coefficients were higher for RNFL thickness than for MDB thickness (P = 0.15 to 0.20). Conclusions: Three-dimensional MDB neuroretinal rim thickness relates to visual function as strongly as the most commonly used SD-OCT parameter for glaucoma, two-dimensional peripapillary RNFL thickness. Translational Relevance: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma.


Subject(s)
Glaucoma, Open-Angle , Optic Disk , Glaucoma, Open-Angle/diagnosis , Humans , Nerve Fibers , Optic Disk/diagnostic imaging , Retinal Ganglion Cells , Tomography, Optical Coherence
2.
J Glaucoma ; 29(10): 952-963, 2020 10.
Article in English | MEDLINE | ID: mdl-32925518

ABSTRACT

PRECIS: In open-angle glaucoma, when neuroretinal rim tissue measured by volumetric optical coherence tomography (OCT) scans is below a third of the normal value, visual field (VF) damage becomes detectable. PURPOSE: To determine the amount of neuroretinal rim tissue thickness below which VF damage becomes detectable. METHODS: In a retrospective cross-sectional study, 1 eye per subject (of 57 healthy and 100 open-angle glaucoma patients) at an academic institution had eye examinations, VF testing, spectral-domain OCT retinal nerve fiber layer (RNFL) thickness measurements, and optic nerve volumetric scans. Using custom algorithms, the minimum distance band (MDB) neuroretinal rim thickness was calculated from optic nerve scans. "Broken-stick" regression was performed for estimating both the MDB and RNFL thickness tipping-point thresholds, below which were associated with initial VF defects in the decibel scale. The slopes for the structure-function relationship above and below the thresholds were computed. Smoothing curves of the MDB and RNFL thickness covariates were evaluated to examine the consistency of the independently identified tipping-point pairs. RESULTS: Plots of VF total deviation against MDB thickness revealed plateaus of VF total deviation unrelated to MDB thickness. Below the thresholds, VF total deviation decreased with MDB thickness, with the associated slopes significantly greater than those above the thresholds (P<0.014). Below 31% of global MDB thickness, and 36.8% and 43.6% of superior and inferior MDB thickness, VF damage becomes detectable. The MDB and RNFL tipping points were in good accordance with the correlation of the MDB and RNFL thickness covariates. CONCLUSIONS: When neuroretinal rim tissue, characterized by MDB thickness in OCT, is below a third of the normal value, VF damage in the decibel scale becomes detectable.


Subject(s)
Glaucoma, Open-Angle/diagnosis , Nerve Fibers/pathology , Optic Disk/pathology , Optic Nerve Diseases/diagnosis , Retinal Ganglion Cells/pathology , Vision Disorders/diagnosis , Visual Fields/physiology , Adult , Aged , Cross-Sectional Studies , Female , Glaucoma, Open-Angle/physiopathology , Humans , Imaging, Three-Dimensional , Intraocular Pressure/physiology , Male , Middle Aged , Models, Theoretical , Optic Disk/diagnostic imaging , Optic Nerve Diseases/physiopathology , Retrospective Studies , Tomography, Optical Coherence/methods , Vision Disorders/physiopathology , Visual Field Tests
3.
Transl Vis Sci Technol ; 9(10): 10, 2020 09.
Article in English | MEDLINE | ID: mdl-32974082

ABSTRACT

Purpose: To compare the rates of clinically significant artifacts for two-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness versus three-dimensional (3D) neuroretinal rim thickness using spectral-domain optical coherence tomography (SD-OCT). Methods: Only one eye per patient was used for analysis of 120 glaucoma patients and 114 normal patients. For RNFL scans and optic nerve scans, 15 artifact types were calculated per B-scan and per eye. Neuroretinal rim tissue was quantified by the minimum distance band (MDB). Global MDB neuroretinal rim thicknesses were calculated before and after manual deletion of B-scans with artifacts and subsequent automated interpolation. A clinically significant artifact was defined as one requiring manual correction or repeat scanning. Results: Among glaucomatous eyes, artifact rates per B-scan were significantly more common in RNFL scans (61.7%, 74 of 120) compared to B-scans in neuroretinal rim volume scans (20.9%, 1423 of 6820) (95% confidence interval [CI], 31.6-50.0; P < 0.0001). For clinically significant artifact rates per eye, optic nerve scans had significantly fewer artifacts (15.8% of glaucomatous eyes, 13.2% of normal eyes) compared to RNFL scans (61.7% of glaucomatous eyes, 25.4% of normal eyes) (glaucoma group: 95% CI, 34.1-57.5, P < 0.0001; normal group: 95% CI, 1.3-23.3, P = 0.03). Conclusions: Compared to the most commonly used RNFL thickness scans, optic nerve volume scans less frequently require manual correction or repeat scanning to obtain accurate measurements. Translational Relevance: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma.


Subject(s)
Glaucoma , Optic Disk , Artifacts , Glaucoma/diagnostic imaging , Humans , Nerve Fibers , Optic Disk/diagnostic imaging , Tomography, Optical Coherence
4.
J Glaucoma ; 28(11): 979-988, 2019 11.
Article in English | MEDLINE | ID: mdl-31599775

ABSTRACT

PRéCIS:: Neuroretinal rim minimum distance band (MDB) thickness is significantly lower in older subjects and African Americans compared with whites. It is similar in both sexes. PURPOSE: To evaluate the relationship between age, race, and sex with the neuroretinal rim using high-density spectral-domain optical coherence tomography optic nerve volume scans of normal eyes. METHODS: A total of 256 normal subjects underwent Spectralis spectral-domain optical coherence tomography optic nerve head volume scans. One eye was randomly selected and analyzed for each subject. Using custom-designed software, the neuroretinal rim MDB thickness was calculated from volume scans, and global and quadrant neuroretinal rim thickness values were determined. The MDB is a 3-dimensional neuroretinal rim band comprised of the shortest distance between the internal limiting membrane and the termination of the retinal pigment epithelium/Bruch's membrane complex. Multiple linear regression analysis was performed to determine the associations of age, race, and sex with neuroretinal rim MDB measurements. RESULTS: The population was 57% female and 69% white with a mean age of 58.4±15.3 years. The mean MDB thickness in the normal population was 278.4±47.5 µm. For this normal population, MDB thickness decreased by 0.84 µm annually (P<0.001). African Americans had thinner MDBs compared with whites (P=0.003). Males and females had similar MDB thickness values (P=0.349). CONCLUSION: Neuroretinal rim MDB thickness measurements decreased significantly with age. African Americans had thinner MDB neuroretinal rims than whites.


Subject(s)
Aging/physiology , Nerve Fibers , Optic Disk/anatomy & histology , Racial Groups/statistics & numerical data , Retina/anatomy & histology , Retinal Ganglion Cells/cytology , Adult , Aged , Corneal Pachymetry , Cross-Sectional Studies , Female , Gonioscopy , Humans , Imaging, Three-Dimensional , Intraocular Pressure/physiology , Male , Middle Aged , Optic Disk/diagnostic imaging , Prospective Studies , Retina/diagnostic imaging , Sex Factors , Slit Lamp Microscopy , Tomography, Optical Coherence/methods , Tonometry, Ocular , Visual Field Tests
5.
J Glaucoma ; 28(8): 708-717, 2019 08.
Article in English | MEDLINE | ID: mdl-31180936

ABSTRACT

PRéCIS:: The diagnostic capability of peripapillary retinal volume is similar to peripapillary retinal nerve fiber layer thickness for diagnosing glaucoma, but with fewer artifacts. PURPOSE: To compare the diagnostic capability of 3-dimensional peripapillary retinal volume (RV) versus 2-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness for open-angle glaucoma. PATIENTS AND METHODS: A retrospective cross-sectional analysis was conducted. A total of 180 subjects (113 open-angle glaucoma, 67 normal participants) had spectral domain optical coherence tomography volume scans and RNFL thickness measurements. Peripapillary RV values were calculated using a custom-designed program with 4 circumpapillary annuli (CA): CA1 had circle diameters of 2.5 and 3.5 mm; CA2, 3 and 4 mm; CA3, 3.5 and 4.5 mm; and CA4, 4 and 5 mm. Area under the receiver operating characteristic curves were calculated for global, quadrant, and octant regions for RV (CA1 to CA4) and RNFL thickness. Pair-wise comparisons were conducted. Artifacts rates were determined. RESULTS: Mean age was 62.7±15.4 years, and 47.8% (86/180) were male. Among RV measurements, best diagnostic performances were for the smallest 2 annuli for inferior RV (CA1: 0.964, CA2: 0.955). Of the 4 annuli, CA1 had the highest diagnostic performance. Of specific regions, the inferior RV quadrant had the highest performance across CA1 to CA4. Peripapillary RV had similar diagnostic capability compared with RNFL thickness (P>0.05). The artifact rate per B-scan for RV was 6.0%, which was significantly lower compared with 2-dimensional RNFL thickness in the same patient population (32.2%, P<0.0001). CONCLUSIONS: The diagnostic capability of RV is similar to RNFL thickness for perimetric open-angle glaucoma, but RV had fewer artifacts compared with RNFL thickness.


Subject(s)
Glaucoma, Open-Angle/diagnosis , Imaging, Three-Dimensional/methods , Retina/diagnostic imaging , Retina/pathology , Software , Tomography, Optical Coherence/methods , Adult , Aged , Aged, 80 and over , Algorithms , Cross-Sectional Studies , Female , Glaucoma, Open-Angle/pathology , Humans , Male , Middle Aged , Nerve Fibers/pathology , Organ Size , Predictive Value of Tests , Retinal Ganglion Cells/pathology , Retrospective Studies
6.
Transl Vis Sci Technol ; 7(6): 12, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30510856

ABSTRACT

PURPOSE: To evaluate the effects of age, race, and ethnicity on the optic nerve and peripapillary retina using spectral-domain optical coherence tomography (SD-OCT) three-dimensional (3D) volume scans in normal subjects. METHODS: This is a cross-sectional study performed at a single institution in Boston. All patients received retinal nerve fiber layer (RNFL) scans and an optic nerve 3D volume scan. The SD-OCT software calculated peripapillary RNFL thickness, retinal thickness (RT), and retinal volume (RV). Custom-designed software calculated neuroretinal rim minimum distance band (MDB) thickness and area. RESULTS: There were 272 normal subjects, including 175 whites, 40 blacks, 40 Asians, and 17 Hispanics. Rates of age-related decline were 2.3%, 2.0%, 1.7%, 3.3%, and 4.3% per decade for RNFL, RT, RV, MDB neuroretinal rim thickness, and MDB area, respectively. The RNFL was most affected by racial and ethnic variations, with Asians having thicker global, superior, and inferior RNFL, Hispanics having thicker inferior RNFL, and blacks having thinner temporal RNFL, compared to whites. For MDB thickness and area, Asians had smaller nasal values and blacks had smaller temporal values. Peripapillary RT and RV parameters were not influenced by race and ethnicity. CONCLUSIONS: All of the parameters exhibited age-related declines. RNFL, MDB thickness, and MDB area demonstrated racial and ethnic variations, while peripapillary RT and RV did not. TRANSLATIONAL RELEVANCE: This study demonstrates that both normal aging and ethnicity affect several novel 3D OCT parameters used to diagnose and monitor glaucoma (i.e., RT, RV, and MDB), and this should be factored in when making clinical decisions based on these parameters.

7.
Invest Ophthalmol Vis Sci ; 59(12): 4998-5010, 2018 10 01.
Article in English | MEDLINE | ID: mdl-30326067

ABSTRACT

Purpose: To compare the diagnostic capability of three-dimensional (3D) macular parameters against traditional two-dimensional (2D) retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography. To determine if manual correction and interpolation of B-scans improve the ability of 3D macular parameters to diagnose glaucoma. Methods: A total of 101 open angle glaucoma patients (29 with early glaucoma) and 57 healthy subjects had peripapillary 2D RNFL thickness and 3D macular volume scans. Four parameters were calculated for six different-sized annuli: total macular thickness (M-thickness), total macular volume (M-volume), ganglion cell complex (GCC) thickness, and GCC volume of the innermost 3 macular layers (retinal nerve fiber layer + ganglion cell layer + inner plexiform layer). All macular parameters were calculated with and without correction and interpolation of frames with artifacts. The areas under the receiver operating characteristic curves (AUROC) were calculated for all the parameters. Results: The 3D macular parameter with the best diagnostic performance was GCC-volume-34, with an inner diameter of 3 mm and an outer of 4 mm. The AUROC for RNFL thickness and GCC-volume-34 were statistically similar for all regions (global: RNFL thickness 0.956, GCC-volume-34 0.939, P value = 0.3827), except for the temporal GCC-volume-34, which was significantly better than temporal RNFL thickness (P value = 0.0067). Correction of artifacts did not significantly change the AUROC of macular parameters (P values between 0.8452 and 1.0000). Conclusions: The diagnostic performance of best macular parameters (GCC-volume-34 and GCC-thickness-34) were similar to or better than 2D RNFL thickness. Manual correction of artifacts with data interpolation is unnecessary in the clinical setting.


Subject(s)
Glaucoma, Open-Angle/diagnosis , Imaging, Three-Dimensional/methods , Nerve Fibers/pathology , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/methods , Aged , Area Under Curve , Female , Glaucoma, Open-Angle/physiopathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Ocular Hypertension/diagnosis , Ocular Hypertension/physiopathology , ROC Curve , Visual Fields/physiology
8.
Am J Ophthalmol ; 182: 180-193, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28807732

ABSTRACT

PURPOSE: To determine the diagnostic capability of peripapillary 3-dimensional (3D) retinal nerve fiber layer (RNFL) volume measurements from spectral-domain optical coherence tomography (OCT) volume scans for open-angle glaucoma (OAG). DESIGN: Assessment of diagnostic accuracy. METHODS: Setting: Academic clinical setting. STUDY POPULATION: Total of 180 patients (113 OAG and 67 normal subjects). OBSERVATION PROCEDURES: One eye per subject was included. Peripapillary 3D RNFL volumes were calculated for global, quadrant, and sector regions, using 4 different-size annuli. Peripapillary 2D RNFL thickness circle scans were also obtained. MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios. RESULTS: Among all 2D and 3D RNFL parameters, best diagnostic capability was associated with inferior quadrant 3D RNFL volume of the smallest annulus (AUROC value 0.977). Otherwise, global 3D RNFL volume AUROC values were comparable to global 2D RNFL thickness AUROC values for all 4 annulus sizes (P values: .0593 to .6866). When comparing the 4 annulus sizes for global RNFL volume, the smallest annulus had the best AUROC values (P values: .0317 to .0380). The smallest-size annulus may have the best diagnostic potential, partly owing to having no areas excluded for being larger than the 6 × 6 mm2 scanned region. CONCLUSION: Peripapillary 3D RNFL volume showed excellent diagnostic performance for detecting glaucoma. Peripapillary 3D RNFL volume parameters have the same or better diagnostic capability compared to peripapillary 2D RNFL thickness measurements, although differences were not statistically significant.


Subject(s)
Glaucoma, Open-Angle/diagnosis , Nerve Fibers/pathology , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/standards , Aged , Area Under Curve , Cross-Sectional Studies , False Negative Reactions , Female , Humans , Imaging, Three-Dimensional , Intraocular Pressure/physiology , Male , Middle Aged , Optic Disk , Predictive Value of Tests , ROC Curve , Reproducibility of Results , Sensitivity and Specificity , Tomography, Optical Coherence/methods , Visual Field Tests , Visual Fields/physiology
9.
J Telemed Telecare ; 23(1): 36-43, 2017 Jan.
Article in English | MEDLINE | ID: mdl-26851243

ABSTRACT

Introduction The goal of this study is to compare image quality and clinical confidence for managing post-operative cataract patients based on anterior segment smartphone images obtained in real-world settings using four types of adapters: (a) macro lens (ML), (b) ML with augmented light-emitting diode (LED) illumination (ML-LED), (c) no adapter (NA) and (d) slit lamp (SL) adapter. Methods Anterior segment images were obtained from 190 eyes after cataract surgery using an eight-megapixel iPhone 6 smartphone camera with four adapters: ML, ML-LED, NA, and SL. Smartphone images were subjectively rated by ophthalmologists as acceptable or not acceptable for: (a) image quality for evaluating the anterior segment structures and (b) reader confidence in clinically managing post-operative patients based on smartphone images. Results NA, ML-LED, and SL had the highest scores for image quality with 100%, 93.7%, and 86.3% judged as acceptable, respectively. NA, SL, and ML-LED were also rated highest in clinical confidence with 100%, 98%, and 93.2% having acceptable levels, respectively. ML was judged lowest in both image quality (61.1% acceptable) and clinical confidence (37.4% acceptable). Discussion This study represents the first effort to compare different smartphone camera adapters' ability to image the anterior segment of the eye in a real-world setting. Our study shows that ML-LED, NA, and SL adapters were acceptable for visualizing anterior segment structures to physician readers in 86-100% of cases. When coupled with visual acuity, intro-ocular pressure and history, these images can result in acceptable clinical confidence in 93-100% of cases.


Subject(s)
Cataract/diagnostic imaging , Diagnostic Techniques, Ophthalmological/instrumentation , Image Processing, Computer-Assisted/standards , Photography/methods , Smartphone , Aged , Anterior Eye Segment/diagnostic imaging , Clinical Competence , Diagnostic Techniques, Ophthalmological/standards , Female , Humans , Male , Middle Aged , Photography/instrumentation , Photography/standards , Postoperative Period , Self Efficacy
10.
Invest Ophthalmol Vis Sci ; 57(13): 5498-5508, 2016 Oct 01.
Article in English | MEDLINE | ID: mdl-27768203

ABSTRACT

PURPOSE: To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. METHODS: Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB) neuroretinal rim parameter. Traditional 150-µm reference surface-based rim parameters (volume, area, and thickness) were also calculated. The diagnostic capabilities of these five parameters were compared with RNFL thickness using the area under the receiver operating characteristic (AUROC) curves. RESULTS: The MDB thickness had significantly higher diagnostic capability than the RNFL thickness in the nasal (0.913 vs. 0.818, P = 0.004) and temporal (0.922 vs. 0.858, P = 0.026) quadrants and the inferonasal (0.950 vs. 0.897, P = 0.011) and superonasal (0.933 vs. 0.868, P = 0.012) sectors. The MDB area and the three neuroretinal rim parameters based on the 150-µm reference surface had diagnostic capabilities similar to RNFL thickness. CONCLUSIONS: The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility. It had higher diagnostic capability than the RNFL thickness in the nasal and temporal quadrants and the inferonasal and superonasal sectors.


Subject(s)
Glaucoma/diagnosis , Imaging, Three-Dimensional , Nerve Fibers/pathology , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/methods , Aged , Cross-Sectional Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , ROC Curve
11.
Am J Ophthalmol ; 169: 168-178, 2016 09.
Article in English | MEDLINE | ID: mdl-27349414

ABSTRACT

PURPOSE: To evaluate the diagnostic performance of a 3-dimensional (3D) neuroretinal rim parameter, the minimum distance band (MDB), using optical coherence tomography (OCT) high-density volume scans for open-angle glaucoma. DESIGN: Reliability analysis. METHODS: setting: Institutional. STUDY POPULATION: Total of 163 patients (105 glaucoma and 58 healthy subjects). OBSERVATION PROCEDURES: One eye of each patient was included. MDB and retinal nerve fiber layer (RNFL) thickness values were determined for 4 quadrants and 4 sectors using a spectral-domain OCT device. MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve (AUROC) values, sensitivities, specificities, and positive and negative predictive values. RESULTS: The best AUROC values of 3D MDB thickness for glaucoma and early glaucoma were for the overall globe (0.969, 0.952), followed by the inferior quadrant (0.966, 0.949) and inferior-temporal sector (0.966, 0.944), and then followed by the superior-temporal sector (0.964, 0.932) and superior quadrant (0.962, 0.924). All 3D MDB thickness AUROC values were higher than those of 2D RNFL thickness. Pairwise comparisons showed that the diagnostic performance of the 3D MDB parameter was significantly better than 2D RNFL thickness only for the nasal quadrant and inferior-nasal and superior-nasal sectors (P = .023-.049). Combining 3D MDB with 2D RNFL parameters provided significantly better diagnostic performance (AUROC 0.984) than most single MDB parameters and all single RNFL parameters. CONCLUSIONS: Compared with the 2D RNFL thickness parameter, the 3D MDB neuroretinal rim thickness parameter had uniformly equal or better diagnostic performance for glaucoma in all regions and was significantly better in the nasal region.


Subject(s)
Glaucoma, Open-Angle/diagnosis , Nerve Fibers/pathology , Optic Disk/pathology , Optic Nerve Diseases/diagnosis , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/methods , Aged , Area Under Curve , False Positive Reactions , Female , Healthy Volunteers , Humans , Imaging, Three-Dimensional , Intraocular Pressure , Male , Middle Aged , Predictive Value of Tests , ROC Curve , Sensitivity and Specificity , Tonometry, Ocular
12.
J Am Soc Nephrol ; 25(9): 1909-15, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24876120

ABSTRACT

Despite the increasing prevalence of CKD in the United States, there is a declining interest among United States medical graduates in nephrology as a career choice. Effective programs are needed to generate interest at early educational stages when career choices can be influenced. The Kidney Disease Screening and Awareness Program (KDSAP) is a novel program initiated at Harvard College that increases student knowledge of and interest in kidney health and disease, interest in nephrology career paths, and participation in kidney disease research. This model, built on physician mentoring, kidney screening of underserved populations, direct interactions with kidney patients, and opportunities to participate in kidney research, can be reproduced and translated to other workforce-challenged subspecialties.


Subject(s)
Kidney Diseases/epidemiology , Models, Educational , Nephrology/education , Career Choice , Community-Institutional Relations , Education, Medical, Graduate , Humans , Mass Screening/methods , Mentors , Training Support , United States/epidemiology
13.
Kidney Int ; 85(1): 124-33, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24048372

ABSTRACT

Our understanding of focal and segmental glomerulosclerosis (FSGS) has advanced significantly from the studies of rare, monogenic forms of the disease. These studies have demonstrated the critical roles of multiple aspects of podocyte function in maintaining glomerular function. A substantial body of research has suggested that the integral membrane protein podocalyxin (PODXL) is required for proper functioning of podocytes, possibly by preserving the patency of the slit diaphragm by negative charge-based repulsion. Exome sequencing of affected cousins from an autosomal dominant pedigree with FSGS identified a cosegregating private variant, PODXL p.L442R, affecting the transmembrane region of the protein. Of the remaining 11 shared gene variants, two segregated with disease, but their gene products were not detected in the glomerulus. In comparison with wild type, this disease-segregating PODXL variant facilitated dimerization. By contrast, this change does not alter protein stability, extracellular domain glycosylation, cell surface expression, global subcellular localization, or interaction with its intracellular binding partner ezrin. Thus, a variant form of PODXL remains the most likely candidate causing FSGS in one family with autosomal dominant inheritance, but its full effect on protein function remains unknown. Our work highlights the challenge faced in the clinical interpretation of whole-exome data for small pedigrees with autosomal dominant diseases.


Subject(s)
Exome/genetics , Glomerulosclerosis, Focal Segmental/genetics , Sialoglycoproteins/genetics , Adolescent , Adult , Animals , Child , Dogs , Female , Genes, Dominant , Genetic Variation , Humans , Madin Darby Canine Kidney Cells , Male , Mice , Middle Aged , Rabbits , Rats , Sequence Analysis, DNA , Young Adult
SELECTION OF CITATIONS