Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Br J Ophthalmol ; 95(11): 1513-8, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21900229

ABSTRACT

AIM: To describe a hybrid technique for anterior lamellar keratoplasty in corneas with topographical irregularities that circumvents the limitations of the microkeratome, namely reproduction of surface irregularities in the lamellar cut when creating the recipient flap. METHOD: Hemi-automated lamellar keratoplasty, a procedure that combines manual recipient bed lamellar dissection with automated donor preparation using a microkeratome, was performed on 14 eyes of 14 patients with heterogeneous causes of anterior stromal scarring. RESULTS: There was an overall improvement in uncorrected visual acuity (UCVA) in 78.6% (11/14) eyes and in best-corrected visual acuity (BCVA) in 78.6% (11/14) eyes at a mean of 9 months postoperatively. Mean preoperative and postoperative logMAR UCVAs were 1.31 ± 0.74 and 0.83 ± 0.46 (p=0.04), respectively. Mean preoperative and postoperative logMAR BCVAs were 0.72 ± 0.58 and 0.38 ± 0.23 (p=0.05). Mean preoperative and postoperative manifest refractive spherical equivalents were -0.76 ± 3.61 D and -0.52 ± 3.44 D (p=0.872). There was no difference in preoperative and postoperative sphere and cylinder (p=0.871 and 0.965, respectively). In a subset of six eyes with longer follow-up >12 months, the UCVA and BCVA show continuing improvement. All grafts remained clear at the final appointment. CONCLUSIONS: Hemi-automated lamellar keratoplasty is an effective and safe surgical procedure in the treatment of corneas with irregular topographic profiles with varying depths of anterior stromal scarring. It combines the benefits of smooth microkeratome lamellar dissection of the donor with customised lenticule thickness and diameter together with a manual lamellar dissection technique for the recipient providing encouraging visual outcomes that show continuing improvement with time.


Subject(s)
Corneal Diseases/surgery , Corneal Transplantation/methods , Adolescent , Adult , Child , Cicatrix/pathology , Cicatrix/physiopathology , Cicatrix/surgery , Cornea/pathology , Corneal Diseases/pathology , Corneal Diseases/physiopathology , Corneal Topography/methods , Corneal Transplantation/adverse effects , Female , Humans , Male , Middle Aged , Refraction, Ocular/physiology , Tomography, Optical Coherence , Treatment Outcome , Visual Acuity/physiology , Young Adult
2.
J Cataract Refract Surg ; 34(11): 1970-5, 2008 Nov.
Article in English | MEDLINE | ID: mdl-19006747

ABSTRACT

PURPOSE: To evaluate the accuracy of the thickness and diameter of corneal disks obtained with the Femtec femtosecond laser (20/10 Perfect Vision) for Descemet-stripping endothelial keratoplasty (DSEK). SETTING: Singapore National Eye Centre, Singapore. METHODS: A femtosecond laser was used to create posterior stromal ablations at varying depths, producing donor lenticules 150 to 200 microm thick with diameters of 7.0 to 9.5 mm (n = 40). After stromal ablation, the central corneal thickness was measured by anterior segment optical coherence tomography and the diameters were measured using imaging software. RESULTS: The mean deviation from the attempted thickness was 15 +/- 14 microm. No correlation was found between the preoperative corneal thickness and the accuracy of the laser ablation (P = .91). No statistically significant differences were found in the accuracy of the laser ablation with multiple-pass nomograms (P = .15). The laser was accurate in producing circular diameters with an arc length between 7.0 mm and 9.5 mm (r2 = 0.935, P = .001). CONCLUSION: The femtosecond laser produced posterior stromal ablations that were accurate in depth of ablation and circularity.


Subject(s)
Corneal Stroma/surgery , Corneal Transplantation , Descemet Membrane/surgery , Endothelium, Corneal/transplantation , Laser Therapy/methods , Tissue Donors , Humans
SELECTION OF CITATIONS
SEARCH DETAIL