1.
Arch Oral Biol ; 165: 106009, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38838513

ABSTRACT

OBJECTIVE: The objective was to measure the thickness of Streptococcus mutans (S. mutans) biofilms forming in an oral biofilm reactor (OBR) by using a noninvasive swept-source optical coherence tomography (SS-OCT) system at every 4 h time interval until 20 h and analyze the correlations with the amounts of biofilms. METHODS: S. mutans biofilms were formed on square-shaped bovine enamel blocks inside an OBR. Biofilms were analyzed at every 4 h stage (4 h, 8 h, 12 h, 16 h and 20 h) using a SS-OCT system and a laser scanning confocal microscope (LSCM). The amounts of biofilms were measured at each stage by separating the water insoluble glucan (WIG) and bacterial cells. Co-relationships between the SS-OCT measured biofilm thickness and the amounts of adhered biofilms were analyzed. RESULTS: The thickness of biofilms detected on SS-OCT images at 4 h stage was 0.059 ± 0.029 (Av ± SD) mm which increased time-dependently in a linear fashion after 8 h stage and reached to 0.435 ± 0.159 mm at 20 h stage and the correlation coefficient was about 0.89. The amounts of biofilms; bacterial optical density (OD) and WIG concentration increased time-dependently were 0.035 ± 0.008 / mm2 and 10.328 ± 2.492 µg/ mm2 respectively at 20 h stage. Correlation coefficients of 0.66 between 'the amounts of bacteria' and 'biofilm thickness on OCT' and 0.67 between 'the amounts of WIG' and 'biofilm thickness on OCT' were obtained, suggesting that there was a relatively positive correlation between them. CONCLUSION: The SS-OCT can be a useful tool to measure time-dependent growth of biofilms. Further studies are needed in order to assess biofilms using SS-OCT more accurately.

2.
J Dent ; 146: 105041, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38762076

ABSTRACT

OBJECTIVES: This study aimed to measure the distribution of silver ion (Ag+), mineral recovery, and nanohardness in carious lesions and comprehensively evaluate the degree of dentin restoration. METHODS: Sixty human teeth with root caries were randomly assigned to the control, silver diammine fluoride (SDF) [Safo], and SDF+Glass ionomer cement (GIC) treatment [Safo+Fuji] groups. Micro-computed tomography (micro-CT) was performed at five time points for each sample before/after treatment to evaluate mineral density within and around carious lesions. Three months following treatment, 12 samples were selected for synchrotron radiation X-ray fluorescence analysis to evaluate Ag+ distribution, while 15 samples were selected for nanoindentation. Data were analyzed using Dunnett's T3 test for micro-CT and Wilcoxon rank sum test with Bonferroni correction (p = 0.017) for nanoindentation. The correlation between hardness and mineral change was analyzed using the Spearman rank correlation coefficient. RESULTS: The Safo and Safo+Fuji groups showed significantly higher mineral recovery rates than did the control group (p < 0.001). In the Safo group, Ag+ accumulated in the deeper layers rather than the superficial layer of caries. In the Safo+Fuji group, Ag+ was found evenly distributed throughout caries, with only a few Ag+ detected in the GIC layer. Hardness in the Safo+Fuji group was significantly higher compared with the Safo group at depths in the range of 10-50 µm. CONCLUSION: In the presence of GICs, SDF exhibited high remineralization capacity when diffusing throughout carious lesions over time. Combined treatment with SDF and GIC could strengthen root dentin even in the presence of caries. CLINICAL SIGNIFICANCE: We found that combination treatment with SDF and GIC could increase mineral density in caries and improve the hardness of the tooth structure compared with fluoride-based agents alone. These findings might pave the way for future clinical trials to determine the therapeutic potential of nanotechnology-based restorative materials.

3.
Clin Oral Investig ; 28(6): 305, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722356

ABSTRACT

OBJECTIVE: To evaluate the ability of the water glass treatment to penetrate zirconia and improve the bond strength of resin cement. MATERIAL AND METHODS: Water glass was applied to zirconia specimens, which were then sintered. The specimens were divided into water-glass-treated and untreated zirconia (control) groups. The surface properties of the water-glass-treated specimens were evaluated using surface roughness and electron probe micro-analyser (EPMA) analysis. A resin cement was used to evaluate the tensile bond strength, with2 and without a silane-containing primer. After 24 h in water storage at 37 °C and thermal cycling, the bond strengths were statistically evaluated with t-test, and the fracture surfaces were observed using SEM. RESULTS: The water glass treatment slightly increased the surface roughness of the zirconia specimens, and the EPMA analysis detected the water glass penetration to be 50 µm below the zirconia surface. The application of primer improved the tensile bond strength in all groups. After 24 h, the water-glass-treated zirconia exhibited a tensile strength of 24.8 ± 5.5 MPa, which was significantly higher than that of the control zirconia (17.6 ± 3.5 MPa) (p < 0.05). After thermal cycling, the water-glass-treated zirconia showed significantly higher tensile strength than the control zirconia. The fracture surface morphology was mainly an adhesive pattern, whereas resin cement residue was occasionally detected on the water-glass-treated zirconia surfaces. CONCLUSION: The water glass treatment resulted in the formation of a stable silica phase on the zirconia surface. This process enabled silane coupling to the zirconia and improved the adhesion of the resin cement.


Subject(s)
Dental Bonding , Glass , Materials Testing , Resin Cements , Silanes , Surface Properties , Tensile Strength , Water , Zirconium , Zirconium/chemistry , Resin Cements/chemistry , Silanes/chemistry , Water/chemistry , Dental Bonding/methods , Glass/chemistry , Microscopy, Electron, Scanning , Dental Stress Analysis
4.
Dent Mater J ; 43(3): 407-414, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38644215

ABSTRACT

This study aimed to evaluate the effects of different resin-coating technique strategies and dual-cure resin luting materials on proximal marginal adaptation and the microtensile bond strengths (µTBSs) of CAD/CAM hybrid ceramic inlays. Extracted human molars were classified into four groups, depending on the coating technique: No coating (None), single coating (1-coating), double coating (2-coating), and flowable resin-coating (Combination). The inlays were bonded with one of the three materials: Panavia V5 (V5), Rely X Ultimate (RXU), and Calibra Ceram (CC). The differences with regard to adaptation were not significant. In the case of µTBS data for V5, no significant differences were observed, whereas for RXU, µTBS values for Combination statistically exceeded those for None and 1-coating. For CC, µTBS values for Combination statistically exceeded those for None, 1-coating, and 2-coating. The coating techniques did not influence the adaptation but influenced the bond strength, and Combination performed the best.


Subject(s)
Ceramics , Computer-Aided Design , Dental Bonding , Dental Marginal Adaptation , Inlays , Materials Testing , Molar , Resin Cements , Surface Properties , Tensile Strength , Humans , Ceramics/chemistry , Dental Bonding/methods , Resin Cements/chemistry , In Vitro Techniques , Dental Stress Analysis , Dental Porcelain/chemistry
5.
J Dent Sci ; 19(2): 900-908, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38618111

ABSTRACT

Background/purpose: Porcine collagen is widely used in regenerative therapies to generate membranes for bone augmentation. However, porcine or bovine gelatin or collagen is often not appropriate for patients with creed and religious beliefs or for allergic reasons. In this study, we evaluated the potential of fish gelatin to generate membranes. Materials and methods: Fish gelatin and hydroxyapatite (HAp) were used at three different ratios (2:0, 2:1, 2:1.5, and 2:2) to prepare gelatin-hydroxyapatite (G-HAp) membranes via freeze-drying and heat-crosslinking. The surface morphology and cell attachment of G-HAp membranes were observed using scanning electron microscopy and confocal laser microscopy. G-HAp membrane was placed at the bottom of a well plate, and MC3T3-E1 cells were seeded on it. Cell viability and cytotoxicity were tested after 1 and 3 days of culture. Alkaline phosphatase (ALP) and alizarin red staining was performed at 10 and 21 days, respectively. Results: Viability of cells on G-HAp membrane with the gelatin:HAp ratio of 2:1.5 was significantly higher than that on membranes with other gelatin:HAp ratios. ALP and alizarin red staining showed that ALP-positive areas and calcium deposition were the highest on G-HAp membrane with the gelatin:HAp ratio of 2:1. These membranes showed negligible cytotoxicity. Conclusion: Fish-derived G-HAp membranes have the potential to promote osteogenic differentiation of MC3T3-E1 cells with negligible cytotoxicity.

6.
Dent Mater J ; 43(2): 303-311, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38447979

ABSTRACT

This study evaluated the bonding performance of coronal dentin disks, designed for biological restoration, and CAD/CAM resin composite disks when bonded to flat dentin surfaces using dual-cure resin cements, with and without a resin-coating (RC) technique. Three distinct groups were established within the non-RC group, each using one of the two types of resin cements in a self-adhesive mode: one-step self-etch adhesive (1-SEA) without light-cure, 1-SEA with light-cure, and a separate group using an alternate cement. Within the RC group, a subgroup was established for each cement. The microtensile bond strength (µTBS) of the disk-dentin beam was tested after 0 and 10,000 thermocycles in a 5°C/55°C. No significant µTBS difference was observed among the non-RC groups. However, when using RC, the µTBSs of coronal dentin disks significantly exceeded those of CAD/CAM resin composite disks. Thermocycle aging did not affect µTBS in any of the bonding methods, except in self-adhesive mode.


Subject(s)
Dental Bonding , Resin Cements , Resin Cements/chemistry , Dental Cements , Dental Bonding/methods , Tensile Strength , Materials Testing , Composite Resins/chemistry , Dentin-Bonding Agents/chemistry , Glass Ionomer Cements , Dentin
7.
Dent Mater ; 40(2): 210-218, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37977993

ABSTRACT

OBJECTIVES: Apatite minerals can have various anions and cations in their crystal structure in addition to phosphate ion (PO4³â») and calcium ion (Ca2+). The aim of this study is to investigate effects of the borate, fluoride and strontium ions on biomimetic nucleation of calcium phosphate. METHODS: Nano-crystalline hydroxyapatite (H-Ap) was obtained from a supersaturated buffered solution containing 4.12 mM HPO42- and 5.88 mM Ca2+ (H-Ap). Four additives were used in solid solution methods: (i) 0.588 mM F- (F-Ap), (ii) 5.88 mM Sr2+ (Sr-Ap), (iii) 4.12 mM BO33- (BO3-Ap), and (iv) a surface pre-reacted glass ionomer (S-PRG) filler eluate that contained 0.17 mM Sr2+, 0.588 mM F-, 11.1 mM BO33-- (SPRG-Ap). Apatite crystallization was investigated using a solid-state magic-angle spinning NMR spectroscopy and X-ray diffraction (XRD) with the Rietveld analysis. RESULTS: A 2D 1H-31P heteronuclear-correlation NMR showed F- ion incorporation in the apatite structure of the F-Ap and SPRG-Ap. The peaks on the 31P axis of the F-Ap, Sr-Ap, and BO3-Ap were different from that of the H-Ap, and the full width at half maximum increased in the following order: H-Ap∼F-Ap∼BO3-Ap< SPRG-Ap< Sr-Ap, suggesting the incorporation of the F-, Sr2+ and BO33-. The incorporation of F and BO3 was further confirmed by 19F and 11B NMR. The XRD revealed that Sr2+ was preferentially incorporated into the CaII site. SIGNIFICANCE: The F-, Sr2+ and BO33-ions might be involved in modifying the crystallization of apatite precipitation, producing a variety of apatite. S-PRG filler that release these ions may have an effect on remineralization, i.e., the reformation of apatite lost due to caries.


Subject(s)
Borates , Fluorides , X-Ray Diffraction , Strontium/chemistry , Biomimetics , Calcium Phosphates/chemistry , Apatites/chemistry , Durapatite/chemistry , Magnetic Resonance Spectroscopy , Ions
8.
J Mech Behav Biomed Mater ; 150: 106295, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38096611

ABSTRACT

OBJECTIVE: To evaluate the effect of ions released from surface pre-reacted glass-ionomer (S-PRG) filler on collagen morphology, remineralization, and ultimate tensile strength (UTS) of demineralized dentin. MATERIALS AND METHODS: Bovine incisor root dentins were demineralized with EDTA and divided into three treatment groups: 1) water (control); 2) S-PRG filler eluate; 3) 125 ppm sodium fluoride (NaF). After a 3-min treatment, the specimens were stored in simulated body fluid (SBF) for 3 months. Collagen morphology and remineralization were assessed using transmission electron microscopy (TEM), scanning electron microscopy (SEM), and Fourier-transform infrared spectroscopy (FTIR). Additionally, ultimate tensile strength (UTS) was measured. RESULTS: TEM and SEM demonstrated that S-PRG induced more effective remineralization compared to NaF, while the control group exhibited faint mineral deposition with collagen degradation. S-PRG displayed the most homogenous mineral deposition in collagen fibrils, along with closure of interfibrillar spaces. Extensive mineral precipitation was observed within dentinal tubules in the S-PRG group. In addition, S-PRG filler eluate demonstrated significantly higher phosphate-to-amide ratio and UTS compared to NaF and control groups (p < 0.05). CONCLUSIONS: Ion released from S-PRG filler positively influenced collagen morphology, remineralization, and ultimate tensile strength of demineralized dentin. CLINICAL SIGNIFICANCE: S-PRG filler enhances remineralization and improve the biomechanics of demineralized dentin.


Subject(s)
Dentin , Silicon Dioxide , Animals , Cattle , Tensile Strength , Collagen/pharmacology , Ions/pharmacology , Glass Ionomer Cements/chemistry
9.
Viruses ; 15(12)2023 12 04.
Article in English | MEDLINE | ID: mdl-38140623

ABSTRACT

To evaluate the changes in respiratory syncytial virus (RSV) collected between 2019 and 2022, we analyzed RSV-A and RSV-B strains from various prefectures in Japan before and after the COVID-19 pandemic. RT-PCR-positive samples collected from children with rapid test positivity at outpatient clinics in 11 prefectures in Japan were sequenced for the ectodomain of the G gene to determine the genotype. Time-aware phylogeographic analyses were performed using the second hypervariable region (HVR) of the G gene from 2012 to 2022. Of 967 samples, 739 (76.4%) were found to be RSV-positive using RT-PCR. RSV peaked in September 2019 but was not detected in 2020, except in Okinawa. Nationwide epidemics occurred with peaks in July 2021 and 2022. The genotype remained the same, ON1 for RSV-A and BA9 for RSV-B during 2019-2022. Phylogeographic analysis of HVR revealed that at least seven clusters of RSV-A had circulated previously but decreased to two clusters after the pandemic, whereas RSV-B had a single monophyletic cluster over the 10 years. Both RSV-A and RSV-B were transferred from Okinawa into other prefectures after the pandemic. The RSV epidemic was suppressed due to pandemic restrictions; however, pre-pandemic genotypes spread nationwide after the pandemic.


Subject(s)
COVID-19 , Respiratory Syncytial Virus Infections , Respiratory Syncytial Virus, Human , Child , Humans , Infant , Respiratory Syncytial Virus Infections/epidemiology , Pandemics , Molecular Epidemiology , Japan/epidemiology , COVID-19/epidemiology , Phylogeny , Respiratory Syncytial Virus, Human/genetics , Genotype
10.
BMC Oral Health ; 23(1): 933, 2023 11 27.
Article in English | MEDLINE | ID: mdl-38012568

ABSTRACT

BACKGROUND: The successful integration of resin-based dental adhesives significantly impacts restorative dentistry, providing efficient and aesthetically pleasing caries treatments. Among various adhesives, one-step self-etching adhesives (1-SEAs) have gained popularity due to their simplicity and short application time. However, concerns have been raised regarding their bonding performance and marginal adaptation characteristics, which differ from two-step self-etching adhesives (2-SEAs) and three-step etch-and-rinse adhesives. Additionally, light-cured bonding materials may encounter challenges in deep cavities and inaccessible areas, necessitating extended light irradiation time. Autocured bonding materials are a potential solution, but limited comparative studies have been conducted on their performance. METHODS: In this in vitro study, we evaluated a new autocured universal bonding material (Bondmer Lightless 2) and compared the results with recent light-cured bonding materials. Microshear bond strength (µSBS) tests were performed on 25 human molars using five different combinations of adhesives and composite resins: Bondmer Lightless 2 with Estelite Bulk Fill Flow (BE group), Bondmer Lightless 2 with a prototype composite resin (BO group), Prime&Bond Universal with SDR flow + (PS group), Scotchbond Universal with Filtek Bulk Fill (SF group), and G-Premio Bond with Gracefil BulkFlo (GG group). The bond strengths and failure modes were assessed using a universal testing machine and scanning electron microscope (SEM), respectively. Marginal adaptation was evaluated using swept-source optical coherence tomography (SS-OCT) and confocal laser scanning microscopy (CLSM) on 40 sound bovine maxillary incisors. RESULTS: The µSBS test showed no significant differences in bond strength among the tested groups. Most failure modes were observed at the bond interface between the adhesive and the dentin. The autocured bonding material demonstrated significantly higher marginal adaptation (SI%) than PS, SF, and GG. The CLSM images corresponded with gaps observed in the SS-OCT images, indicating improved marginal sealing in the autocured group. CONCLUSIONS: The new autocured universal bonding material exhibited comparable bond strength to a conventional light-cured material while demonstrating a superior marginal adaptation level. This finding suggested that the autocured material could be a valuable alternative, especially when extended light irradiation would pose a challenge. Further clinical studies would be warranted to evaluate the performance of the autocured bonding material in actual restorative dental practice.


Subject(s)
Dental Bonding , Dental Cements , Animals , Cattle , Humans , Dental Bonding/methods , Composite Resins/chemistry , Dental Materials/chemistry , Resin Cements/chemistry , Dentin , Materials Testing , Tensile Strength
11.
J Adhes Dent ; 25(1): 219-230, 2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37910068

ABSTRACT

PURPOSE: The first objective was to determine if dual-curing of resin cement with reduced light could affect interfacial adaptations of zirconia restoration. The second objective was to examine whether cement type and pretreatment method of universal adhesive affected interfacial adaptation. The final objective was to compare the polymerization degree of cement under different reduced-light conditions. MATERIALS AND METHODS: Inlay cavities were prepared on extracted third molars. Translucent zirconia restorations were milled using Katana UTML (Kuraray Noritake) in three groups with restoration thicknesses of 1, 2, and 3 mm, respectively. Each group had three subgroups using different cementation methods. For subgroup 1, restorations were cemented with self-adhesive cement. For subgroup 2, universal adhesive was applied and light cured. After the restoration was seated with conventional resin cement, light curing was performed. For subgroup 3, after adhesive was applied, the restoration was seated with conventional resin cement. Light curing was performed for the adhesive and cement simultaneously. After thermocycling, interfacial adaptation at the restoration-tooth interface was investigated using swept-source optical coherence tomography imaging. Finally, polymerization shrinkage of the cement was measured using a linometer and compared under the conditions of different zirconia thicknesses and light-curing durations. RESULTS: Interfacial adaptation varied signficantly depending on the zirconia thickness, pretreatment, polymerization mode and cements used (p < 0.05). The effects of the adhesive and polymerization shrinkage differed signficantly, depending on the reduced light under the zirconia (p < 0.05). CONCLUSION: Lower curing-light irradiance may lead to inferior adaptation and lower polymerization of the cement. Polymerization of resin cement can differ depending on the light irradiance and exposure duration.


Subject(s)
Dental Cements , Resin Cements , Polymerization , Glass Ionomer Cements
12.
J Adhes Dent ; 25(1): 187-194, 2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37843501

ABSTRACT

PURPOSE: Resin composites are commonly used in pediatric dentistry, but there is limited evidence on adhesion to primary teeth, especially primary enamel. In this study, three bonding strategies were assessed - one-step self-etch (1-SE), two-step self-etch (2-SE), and three-step etch-and-rinse (3-ER) - by measuring the immediate and aged microshear bond strength (µSBS) to sound primary enamel. MATERIALS AND METHODS: 120 extracted human primary molars with sound buccal surfaces were used for µSBS testing. Six adhesive protocols (two per bonding strategy) were selected and µSBS was measured either after 24 h or 10,000 thermal cycles (n = 10). Confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM) were used to determine failure modes. Furthermore, 18 primary molars were etched using the different adhesive protocols (n = 3) for the measurement of surface roughness (Sa) using CLSM and morphological analysis using SEM. RESULTS: After 24 h, there was no significant difference in µSBS between 1-SE and 2-SE strategies (p = 0.96), but the 2-SE strategy yielded significantly higher µSBS after thermocycling (p < 0.001). The highest µSBS was obtained using the 3-ER strategy regardless of aging (p < 0.001). The 3-ER strategy clearly exposed enamel prisms and resulted in the highest Sa (p < 0.001). In contrast, if SE strategies were used, enamel prisms were barely recognizable, and Sa was not significantly different from baseline (p > 0.95). CONCLUSION: The 3-ER strategy is optimal for bonding to primary enamel. The etching effect of SE strategies is weaker, resulting in lower µSBS. Thermocycling revealed that the bonding durability of the 1-SE strategy is inferior to that of to multi-step strategies.


Subject(s)
Dental Bonding , Dental Cements , Child , Humans , Aged , Resin Cements , Dentin-Bonding Agents , Dental Bonding/methods , Dentin , Materials Testing , Dental Enamel
13.
J Funct Biomater ; 14(7)2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37504881

ABSTRACT

In-office bleaching with high concentrations of hydrogen peroxide (H2O2) agents causes undesirable alterations in the enamel. Surface pre-reacted glass-ionomer (S-PRG) filler is a functional material known for its acid-neutralizing and demineralization-inhibition properties. This study evaluates the effect of S-PRG filler incorporation in H2O2-based bleaching on the enamel surface. Bovine enamel surfaces were bleached using a bleaching paste formulated with a liquid (35% H2O2) and a powder containing 5% or 10% S-PRG filler. The surface roughness and the Vickers microhardness of the treated enamel surfaces were evaluated. The enamel surfaces were observed under a scanning electron microscope (SEM) and analyzed using energy dispersive X-ray (EDX) technology. The surfaces were challenged by citric acid and observed by SEM. The specimens bleached with the paste containing the S-PRG filler showed lower enamel surface roughness and higher microhardness values than did those bleached with the plain paste (0% S-PRG filler); meanwhile, there were no significant differences between the 5% or 10% S-PRG filler groups. The S-PRG filler groups showed enamel surface morphologies similar to those of the non-bleached enamel, according to SEM observation, and EDX analysis detected the presence of fluoride and strontium ions. The S-PRG filler groups showed a higher resistance to erosion. The S-PRG filler mitigated the detrimental effects of bleaching agents on the enamel surface and provided resistance to erosion.

14.
Dent Mater J ; 42(4): 552-558, 2023 Aug 02.
Article in English | MEDLINE | ID: mdl-37271540

ABSTRACT

To investigate the influence of phosphoric acid etching on the dentin enamel junction (DEJ) using optical coherence tomography (OCT). Human teeth were assigned to four groups: 1. control, no additional treatment (CT); 2. The primer of "SE Bond2" was applied (SE), 3. "Enamel Conditioner" was applied (EC), 4. "K-etchant syringe" was applied (KE). After treatment, the DEJ was observed using a laser microscope (CLSM), OCT, and scanning electron microscopy (SEM). Additionally, an ultimate tensile strength (UTS) test at the DEJ was performed. No cracks were observed by CLSM. In contrast, cracks were observed all samples by SEM. Additionally, OCT revealed a white line along the DEJ in all KE specimens and some EC specimens. The UTS test showed a significant difference between CT and KE. This study found that phosphoric acid etching may cause excessive demineralization and weaken the DEJ. This fragility was observed using a non-invasive diagnostic method using OCT.


Subject(s)
Dental Bonding , Resin Cements , Humans , Tomography, Optical Coherence/methods , Acid Etching, Dental/methods , Phosphoric Acids , Dental Enamel , Dentin , Microscopy, Electron, Scanning , Dental Bonding/methods
15.
J Dent ; 135: 104602, 2023 08.
Article in English | MEDLINE | ID: mdl-37391026

ABSTRACT

OBJECTIVE: To identify the remineralization activity of enamel subsurface lesions using different percentages of surface pre-reacted glass-ionomer (S-PRG) filler containing gum-base material. METHODS: Gum extracts from gum-base materials containing 0wt%, 5wt%, and 10wt% S-PRG filler were prepared as GE0, GE5, and GE10, respectively. A total of 50 bovine enamel specimens were used, and the polished enamel surface of a 3 × 3 mm2 window area was exposed. The specimens were then subjected to a demineralization solution for seven days to create a subsurface enamel lesion. Remineralization was then conducted for seven days using a protocol whereby the specimens were immersed three times a day in prepared gum extracts (0wt%, 5wt%, and 10wt%) and artificial saliva of pH 7 (Control) for 20 min at 37 °C. Thereafter, remineralization assessment was performed by using Swept Source Optical Coherence Tomography (SS-OCT) and micro-computed tomography (µCT). Surface morphology and elemental analysis were conducted by scanning electron microscopy (SEM) and energy-dispersive X-ray spectrometry (EDS). RESULTS: The depths of the demineralized lesions in the GE5 and GE10 groups were significantly lower than those of the Control and the GE0 groups. SEM observations of the enamel surface morphology of the GE5 and GE10 groups indicated remineralization with S-PRG filler-related elements present. CONCLUSION: The GE5 and GE10 S-PRG filler containing gum-base materials showed significantly improved surface remineralization and reduced demineralization of the enamel lesions. EDS analysis suggested that the released ions from the S-PRG filler might be responsible for surface remineralization. CLINICAL SIGNIFICANCE: The S-PRG filler containing gum-base material may have a significant remineralization effect and improve the surface morphology of enamel subsurface lesions.


Subject(s)
Dental Enamel , Tooth Demineralization , Animals , Cattle , Humans , X-Ray Microtomography , Acrylic Resins , Tooth Demineralization/diagnostic imaging , Tooth Demineralization/drug therapy , Tooth Remineralization
16.
Clin Oral Investig ; 27(7): 4051-4059, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37133698

ABSTRACT

OBJECTIVES: Surface reaction-type pre-reacted glass-ionomer (S-PRG) filler releases six types of ions with a neutralizing ability. This study evaluated the effect of S-PRG filler incorporation in an H2O2-based bleaching material on the bleaching efficacy, pH, and reaction state. MATERIALS AND METHODS: The experimental bleaching material was formulated by the addition of 5% or 10% S-PRG fillers to the powder part. The stained bovine teeth were treated with the prepared bleaching paste. Commission internationale de l'éclairage (CIE) L*a*b* color space values were recorded before and after bleaching, and the color difference (ΔE) and whiteness index (WID) were calculated. Moreover, the used bleaching formulations were assessed for their pH values and reaction state by evaluating the oxidation state of manganese (Mn+2) using electron spin resonance (ESR). RESULTS: The results of ΔE and WID showed that the addition of S-PRG filler increased the bleaching effect, but there was no significant difference between the groups with 5% and 10% S-PRG filler. A significant increase in pH in S-PRG filler groups (5% pH 6.7, 10% pH 6.8) was found compared to the 0% group (pH 4.8). ESR measurements showed that the signal emitted from Mn+2 decreased over time. The S-PRG filler groups showed a significantly higher reduction in Mn+2 compared to the 0% group, with no significant difference between the 5% and 10% S-PRG groups. CONCLUSIONS: S-PRG filler addition resulted in improved bleaching efficacy, higher reaction rate, and pH values that are close to neutral. CLINICAL RELEVANCE: S-PRG filler addition may be effective on the bleaching outcome of H2O2-based materials.


Subject(s)
Glass Ionomer Cements , Hydrogen Peroxide , Animals , Cattle , Electron Spin Resonance Spectroscopy , Hypochlorous Acid , Hydrogen-Ion Concentration
17.
Dent Mater J ; 42(3): 426-432, 2023 May 30.
Article in English | MEDLINE | ID: mdl-37032103

ABSTRACT

Volumetric shrinkage (VS) of conventional, bulk-fill, and core build-up resin-based composites (RBCs) of various thickness (1-5 mm) was measured using the modified bonded-disk method with confocal laser scanning microscopy. Additionally, the bottom-to-top ratio of Vickers hardness (%VH) was measured. Conventional RBCs exhibited significantly higher VS than bulk-fill and core build-up RBCs (p<0.05). As specimen thickness increased, VS relative to volume (%VS) and difference in VS at each depth (VSdepth) decreased. For conventional RBCs, there was a significant drop in VSdepth between 1 mm and 2 mm (p<0.05), and another drop was observed between 3 mm and 4 mm (p<0.05) where %VH decreased below 90%. For bulk-fill and core build-up RBCs, VSdepth decreased significantly between 2 mm and 3 mm (p<0.05), but %VH exceeded 90% even in 5 mm deep cavities. These results indicated that post-curing contributed to lower shrinkage in deeper layers, and that conventional RBCs were not adequately polymerized at the depth of over 3 mm.


Subject(s)
Composite Resins , Dental Caries , Humans , Polymerization , Materials Testing , Dental Materials , Hardness , Surface Properties , Light-Curing of Dental Adhesives/methods
18.
BMC Infect Dis ; 23(1): 188, 2023 Mar 29.
Article in English | MEDLINE | ID: mdl-36991360

ABSTRACT

BACKGROUND: This study assessed the differences in daily virus reduction and the residual infectivity after the recommended home stay period in Japan in patients infected with influenza and treated with baloxavir (BA), laninamivir (LA), oseltamivir (OS), and zanamivir (ZA). METHODS: We conducted an observational study on children and adults at 13 outpatient clinics in 11 prefectures in Japan during seven influenza seasons from 2013/2014 to 2019/2020. Virus samples were collected twice from influenza rapid test-positive patients at the first and second visit 4-5 days after the start of treatment. The viral RNA shedding was quantified using quantitative RT-PCR. Neuraminidase (NA) and polymerase acidic (PA) variant viruses that reduce susceptibility to NA inhibitors and BA, respectively, were screened using RT-PCR and genetic sequencing. Daily estimated viral reduction was evaluated using univariate and multivariate analyses for the factors such as age, treatment, vaccination status, or the emergence of PA or NA variants. The potential infectivity of the viral RNA shedding at the second visit samples was determined using the Receiver Operator Curve based on the positivity of virus isolation. RESULTS: Among 518 patients, 465 (80.0%) and 116 (20.0%) were infected with influenza A (189 with BA, 58 with LA, 181 with OS, 37 with ZA) and influenza B (39 with BA, 10 with LA, 52 with OS, 15 with ZA). The emergence of 21 PA variants in influenza A was detected after BA treatment, but NA variants were not detected after NAIs treatment. Multiple linear regression analysis showed that the daily viral RNA shedding reduction in patients was slower in the two NAIs (OS and LA) than in BA, influenza B infection, aged 0-5 years, or the emergence of PA variants. The residual viral RNA shedding potentially infectious was detected in approximately 10-30% of the patients aged 6-18 years after five days of onset. CONCLUSIONS: Viral clearance differed by age, type of influenza, choice of treatment, and susceptibility to BA. Additionally, the recommended homestay period in Japan seemed insufficient, but reduced viral spread to some extent since most school-age patients became non-infectious after 5 days of onset.


Subject(s)
Influenza, Human , Child , Adult , Humans , Influenza, Human/drug therapy , Neuraminidase/genetics , Outpatients , Japan , Seasons , Antiviral Agents/therapeutic use , Antiviral Agents/pharmacology , Zanamivir/therapeutic use , Oseltamivir/therapeutic use , Enzyme Inhibitors/therapeutic use , RNA, Viral/genetics
19.
J Dent ; 131: 104452, 2023 04.
Article in English | MEDLINE | ID: mdl-36804340

ABSTRACT

OBJECTIVES: This study aimed to evaluate the change of mineral content in dentine lesions over time and examine the effectiveness of the combined treatment with silver diammine fluoride (SDF) and glass ionomer cement (GIC). METHODS: Sixty bovine dentine specimens were divided into 4 groups: cont, Fuji, Safo, and Safo+Fuji. The specimens were imaged and measured using microcomputed tomography (microCT) at 7 time points: pre-demineralisation, after demineralisation for two weeks, immediately after treatment, 1 week, 2 weeks, 1 month, and 3 months after treatment. The 3-month group was evaluated with a light microscope, attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, and scanning electron microscope (SEM)/energy-dispersive X-ray spectroscopy (EDS). Data were analysed by Dunn's test and Wilcoxon signed rank test with Bonferroni correction for microCT, and Kruskal-Wallis test and two-way analysis of variance for EDS characterisation. RESULTS: MicroCT images showed high mineral density beneath dentine lesions in Safo+Fuji. The mineral density at 600 µm in Safo+Fuji increased significantly over time, while Safo showed an opposite trend (adjusted p<0.005). In Safo+Fuji, EDS revealed significantly high energy of fluorine (p<0.05, at 300 µm) and a tendency towards high energy of calcium (p>0.05). However, Safo+Fuji showed lower energy of silver compared to Safo (p<0.001). ATR-FTIR revealed that phosphate groups had the highest peak at a depth between 300 and 400 µm in Safo+Fuji. CONCLUSIONS: Safo+Fuji was effective in remineralising the deep lesion in dentine after one and three months, and a hypermineralisation zone generated beneath the lesion demonstrated additional benefit in this study. CLINICAL SIGNIFICANCE: This long-term in vitro study showed that SDF+GIC treatment could strengthen the structure of decayed teeth when applied in the treatment of patients with advanced rampant caries.


Subject(s)
Fluorides , Glass Ionomer Cements , Humans , Animals , Cattle , Glass Ionomer Cements/pharmacology , Glass Ionomer Cements/therapeutic use , Fluorides/pharmacology , Fluorides/therapeutic use , Fluorides/analysis , X-Ray Microtomography , Silver Compounds/pharmacology , Minerals/analysis , Dentin/pathology
20.
J Mech Behav Biomed Mater ; 140: 105692, 2023 04.
Article in English | MEDLINE | ID: mdl-36753849

ABSTRACT

OBJECTIVES: To examine the micro tensile bond strength (µTBS) and the resin-dentin interface on a laser-irradiated dentin surface using two different irradiation methods, with or without additional low-energy irradiation. METHODS: The flat bovine dentin surface was divided into three groups: i). control group (C group, no irradiation), ii) 80 mJ/pulse Er: YAG laser group (80 group), iii) 80 + 30 mJ/pulse Er: YAG laser group (80 + 30 group, with an additional 30 mJ/pulse). After the roughness of the dentin surface was recorded, Clearfil SE Bond 2 or Clearfil Universal Bond Quick (Kuraray Noritake Dental Inc., Tokyo, Japan) was applied. After the µTBS testing, the failure mode was observed. The bonded interface was assessed using Rhodamine-dye incorporated adhesives and observed by optical coherence tomography. RESULTS: The dentin surface showed opened dentinal tubules without a smear layer after irradiation. For both adhesives, the µTBS was significantly higher in 80 + 30 group than in the 80 group (p < 0.05). In the 80 group, the thickness of the adhesive layer was not uniform, and the dentin surface was occasionally in direct contact with the composite resin. The failure mode images showed that most of the fractures in the 80 group were at the sub-surface of irradiated dentin. The adhesive layers of the 80 + 30 groups were homogeneous. CONCLUSIONS: The dentin surface was rough and irregular by 80 mJ irradiation, which might result in an inadequate resin-dentin interface and the weak µTBS. The bonded integrity was mitigated by additional irradiation.


Subject(s)
Dental Bonding , Lasers, Solid-State , Animals , Cattle , Dentin/radiation effects , Composite Resins/chemistry , Resin Cements/chemistry , Adhesives , Tensile Strength , Dentin-Bonding Agents , Microscopy, Electron, Scanning
SELECTION OF CITATIONS