1.
Sensors (Basel) ; 24(11)2024 May 29.
Article in English | MEDLINE | ID: mdl-38894287

ABSTRACT

Upper-limb paralysis requires extensive rehabilitation to recover functionality for everyday living, and such assistance can be supported with robot technology. Against such a background, we have proposed an electromyography (EMG)-driven hybrid rehabilitation system based on motion estimation using a probabilistic neural network. The system controls a robot and functional electrical stimulation (FES) from movement estimation using EMG signals based on the user's intention, enabling intuitive learning of joint motion and muscle contraction capacity even for multiple motions. In this study, hybrid and visual-feedback training were conducted with pointing movements involving the non-dominant wrist, and the motor learning effect was examined via quantitative evaluation of accuracy, stability, and smoothness. The results show that hybrid instruction was as effective as visual feedback training in all aspects. Accordingly, passive hybrid instruction using the proposed system can be considered effective in promoting motor learning and rehabilitation for paralysis with inability to perform voluntary movements.


Subject(s)
Electromyography , Learning , Robotics , Humans , Electromyography/methods , Learning/physiology , Robotics/methods , Male , Movement/physiology , Neural Networks, Computer , Adult , Female , Motion
2.
Article in English | MEDLINE | ID: mdl-38861447

ABSTRACT

Postural control is one of the primary body functions for fall prevention. Unexpected perturbation-based balance training is effective for improving postural control. However, the effect of perturbation-based training using assistive devices on muscle activity and co-contraction for standing balance is still unclear. This training is also difficult to perform easily because it requires large instruments or expert guidance. The purpose of this study is to demonstrate the effect of perturbation-based balance training using a wearable balance training device (WBTD) on postural control. In this study, fourteen healthy young adult males were assigned to either a WBTD group or a sham group. In the intervention session, participants in the WBTD group were perturbed either left or right direction at random timing by the WBTD during tandem stance balance training. Participants in the Sham group did not receive external perturbation during tandem stance balance training. Before and after the intervention session, participants of both groups underwent unexpected lateral perturbation postural control testing (pre- and post-test). The normalized integral of electromyography (IEMG), co-contraction index (CCI), and center of pressure (COP) parameters were measured in the pre- and post-test. Experimental results showed that the WBTD group in the post-test significantly decreased left Gluteus Medius IEMG, CCI of both Gluteus Medius, and peak [Formula: see text] velocity, compared to those of the pre-test ( [Formula: see text], p =0.024 , p =0.031 , respectively). We conclude that balance training using WBTD could improve flexible postural control adjustment via cooperative muscle activation.


Subject(s)
Electromyography , Healthy Volunteers , Muscle Contraction , Muscle, Skeletal , Postural Balance , Standing Position , Wearable Electronic Devices , Humans , Male , Postural Balance/physiology , Young Adult , Muscle, Skeletal/physiology , Muscle Contraction/physiology , Adult
3.
Sci Rep ; 14(1): 11198, 2024 05 16.
Article in English | MEDLINE | ID: mdl-38755393

ABSTRACT

Variations in the autonomic nervous system activity during exercise therapy in patients with cardiovascular diseases may lead to adverse events. Aromatherapy may reduce these adverse events by enhancing parasympathetic nervous activity (PNA). However, the effects of aromatherapy during exercise remain relatively unknown. This study aimed to evaluate the effect of aromatherapy on autonomic nervous activity during exercise and recovery. This randomized crossover study included 20 healthy men subjected to both aroma and placebo conditions which involved rest and moderate-intensity aerobic exercise on a cycle ergometer, followed by recovery. Blood pressure, heart rate variability indices, and SpO2 were measured during the rest, exercise, and recovery phases. Moreover, aroma preferences and emotional changes in response to the aroma were assessed. Under the placebo condition, high frequency (HF), root mean square of successive differences indices, and heart rate showed delayed recovery (P < 0.05). Furthermore, a moderate positive correlation was identified between aroma preference, pleasant emotions induced by aromatherapy, and the HF index (P < 0.05). These results indicate that aromatherapy facilitates the recovery of PNA after exercise. Furthermore, these effects were more pronounced among individuals who exhibited a stronger preference for and more positive emotions toward aromas.


Subject(s)
Aromatherapy , Autonomic Nervous System , Cross-Over Studies , Exercise , Heart Rate , Humans , Aromatherapy/methods , Male , Exercise/physiology , Autonomic Nervous System/physiology , Heart Rate/physiology , Adult , Young Adult , Blood Pressure/physiology , Odorants
4.
IEEE J Transl Eng Health Med ; 11: 515-522, 2023.
Article in English | MEDLINE | ID: mdl-38059063

ABSTRACT

Reactive postural control is an important component of the balance function for fall prevention. Perturbation-based balance exercises improve reactive postural control; however, these exercises require large, complex instruments and expert medical guidance. This study investigates the effects of unexpected perturbation-based balance exercises using a wearable balance exercise device (WBED) on reactive postural control. Eighteen healthy adult males participated in this study. Participants were assigned to the WBED and Sham groups. In the intervention session, participants in the WBED group randomly underwent unexpected perturbation in the mediolateral direction, while the Sham group performed the same exercises without perturbation. Before and after the intervention session, all participants underwent evaluation of reactive balance function using air cylinders. Peak displacement (D), time at peak displacement (T), peak velocity (V), and root mean square (RMS) of center of pressure (COP) data were measured. For mediolateral and anteroposterior COP (COPML and COP[Formula: see text]), the main effects of group and time factors (pre/post) were investigated through the analysis of variance for split-plot factorial design. In the WBED group, the D-COPML and V-COPML of the post-test significantly decreased compared to those of the pre-test (p = 0.017 and p = 0.003, respectively). Furthermore, the D-COPAP and RMSAP of the post-test significantly decreased compared to those of the pre-test (p = 0.036 and p = 0.015, respectively). This study proved that the perturbation-based balance exercise using WBED immediately improved reactive postural control. Therefore, wearable exercise devices, such as WBED, may contribute to the prevention of falls and fall-related injuries.


Subject(s)
Exercise Therapy , Exercise , Adult , Humans , Male , Postural Balance , Research Design , Time Factors
5.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Article in English | MEDLINE | ID: mdl-37941241

ABSTRACT

Patients with upper limb paralysis undergo various types of rehabilitation to reconstruct upper limb functions necessary for their return to daily life and social activities. Therefore, it is necessary to develop an effective rehabilitation support system using robotic technologies. In this study, we propose an EMG-driven hybrid rehabilitation system based on the estimation of intended motion using a probabilistic neural network. In the proposed system, the developed robot and functional electrical stimulation are controlled by estimating the patient's intention, which enables the intuitive learning of the appropriate control abilities of joint motions and muscle contraction patterns. In the experiments, hybrid and visual feedback training were conducted for pointing movements of the wrist joint of the non-dominant hand. The results confirmed that the proposed method provides effective training and has great potential for use in rehabilitation.


Subject(s)
Robotics , Upper Extremity , Humans , Upper Extremity/physiology , Robotics/methods , Wrist Joint/physiology , Neural Networks, Computer , Movement/physiology , Electromyography/methods
6.
Sci Rep ; 13(1): 13869, 2023 08 24.
Article in English | MEDLINE | ID: mdl-37620366

ABSTRACT

Infants make spontaneous movements from the prenatal period. Several studies indicate that an atypical pattern of body motion during infancy could be utilized as an early biomarker of autism spectrum disorders (ASD). However, to date, little is known about whether the body motion pattern in neonates is associated with ASD risk. The present study sought to clarify this point by examining, in a longitudinal design, the link between features of spontaneous movement at about two days after birth and ASD risk evaluated using the Modified Checklist for Autism in Toddlers by their caregivers at 18 months old. The body movement features were quantified by a recently developed markerless system of infant body motion analysis. Logistic regression analysis revealed that ASD risk at 18 months old is associated with the pattern of spontaneous movement at the neonatal stage. Further, logistic regression based on body movement features during sleep shows better performance in classifying high- and low-risk infants than during the awake state. These findings raise the possibility that early signs of ASD risk may emerge at a developmental stage far earlier than previously thought.


Subject(s)
Autism Spectrum Disorder , Autistic Disorder , Infant , Infant, Newborn , Female , Pregnancy , Humans , Autism Spectrum Disorder/diagnosis , Movement , Motion , Checklist
7.
Sci Rep ; 12(1): 17719, 2022 10 21.
Article in English | MEDLINE | ID: mdl-36271241

ABSTRACT

A markerless gait analysis system can measure useful gait metrics to determine effective clinical treatment. Although this gait analysis system does not require a large space, several markers, or time constraints, it inaccurately measure lower limb joint kinematics during gait. In particular, it has a substantial ankle joint angle error. In this study, we investigated the markerless gait analysis method capability using single RGB camera-based pose estimation by OpenPose (OP) and an inertial measurement unit (IMU) sensor on the foot segment to measure ankle joint kinematics under various gait conditions. Sixteen healthy young adult males participated in the study. We compared temporo-spatial parameters and lower limb joint angles during four gait conditions with varying gait speeds and foot progression angles. These were measured by optoelectronic motion capture, markerless gait analysis method using OP, and proposed method using OP and IMU. We found that the proposed method using OP and an IMU significantly decreased the mean absolute errors of peak ankle joint angles compared with OP in the four gait conditions. The proposed method has the potential to measure temporo-spatial gait parameters and lower limb joint angles, including ankle angles, in various gait conditions as a clinical settings gait assessment tool.


Subject(s)
Gait Analysis , Gait , Male , Young Adult , Humans , Biomechanical Phenomena , Ankle Joint , Ankle , Walking
8.
Sci Rep ; 12(1): 18045, 2022 10 27.
Article in English | MEDLINE | ID: mdl-36302797

ABSTRACT

Early intervention is now considered the core treatment strategy for autism spectrum disorders (ASD). Thus, it is of significant clinical importance to establish a screening tool for the early detection of ASD in infants. To achieve this goal, in a longitudinal design, we analyzed spontaneous bodily movements of 4-month-old infants from general population and assessed their ASD-like behaviors at 18 months of age. A total of 26 movement features were calculated from video-recorded bodily movements of infants at 4 months of age. Their risk of ASD was assessed at 18 months of age with the Modified Checklist for Autism in Toddlerhood, a widely used screening questionnaire. Infants at high risk for ASD at 18 months of age exhibited less rhythmic and weaker bodily movement patterns at 4 months of age than low-risk infants. When the observed bodily movement patterns were submitted to a machine learning-based analysis, linear and non-linear classifiers successfully predicted ASD-like behavior at 18 months of age based on the bodily movement patterns at 4 months of age, at the level acceptable for practical use. This study analyzed the relationship between spontaneous bodily movements at 4 months of age and the ASD risk at 18 months of age. Experimental results suggested the utility of the proposed method for the early screening of infants at risk for ASD. We revealed that the signs of ASD risk could be detected as early as 4 months after birth, by focusing on the infant's spontaneous bodily movements.


Subject(s)
Autism Spectrum Disorder , Autistic Disorder , Infant , Humans , Autistic Disorder/diagnosis , Autism Spectrum Disorder/diagnosis , Movement , Early Diagnosis , Risk
9.
PLoS One ; 17(1): e0262181, 2022.
Article in English | MEDLINE | ID: mdl-34995315

ABSTRACT

Multiple cameras are used to resolve occlusion problem that often occur in single-view human activity recognition. Based on the success of learning representation with deep neural networks (DNNs), recent works have proposed DNNs models to estimate human activity from multi-view inputs. However, currently available datasets are inadequate in training DNNs model to obtain high accuracy rate. Against such an issue, this study presents a DNNs model, trained by employing transfer learning and shared-weight techniques, to classify human activity from multiple cameras. The model comprised pre-trained convolutional neural networks (CNNs), attention layers, long short-term memory networks with residual learning (LSTMRes), and Softmax layers. The experimental results suggested that the proposed model could achieve a promising performance on challenging MVHAR datasets: IXMAS (97.27%) and i3DPost (96.87%). A competitive recognition rate was also observed in online classification.


Subject(s)
Attention/physiology , Human Activities/statistics & numerical data , Learning/physiology , Memory/physiology , Neural Networks, Computer , Recognition, Psychology , Humans
10.
Article in English | MEDLINE | ID: mdl-34914592

ABSTRACT

A cost-effective gait analysis system without attachments and specialized large environments can provide useful information to determine effective treatment in clinical sites. This study investigates the capability of a single camera-based pose estimation system using OpenPose (OP) to measure the temporo-spatial and joint kinematics parameters during gait with orthosis. Eleven healthy adult males walked under different conditions of speed and foot progression angle (FPA). Temporo-spatial and joint kinematics parameters were measured using a single camera-based system with OP and a three-dimensional motion capture system. The limit of agreement, mean absolute error, absolute agreement (ICC2, 1), and relative consistency (ICC3, 1) between the systems under each condition were assessed for reliability and validity. The results demonstrated that most of the ICC for temporo-spatial parameters and hip and knee kinematics parameters were good to excellent (0.60 - 0.98). Conversely, most of the ICC for ankle kinematics in all conditions were poor to fair (< 0.60). Thus, the gait analysis using OP can be used as a clinical assessment tool for determining the temporo-spatial, hip, and knee sagittal plane angles during gait.


Subject(s)
Gait , Orthotic Devices , Adult , Ankle Joint , Biomechanical Phenomena , Humans , Knee Joint , Lower Extremity , Male , Reproducibility of Results , Walking
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3709-3712, 2021 11.
Article in English | MEDLINE | ID: mdl-34892042

ABSTRACT

This paper proposes an evaluation/treatment sup-port system enabling automatic determination of wound evaluation indices from RGB-depth images and fully convolutional networks (FCNs). Segmentation experiments based on wound images and surface area determination experiments based on artificial images showed reduced errors and smaller parameters/higher levels of tissue classification than with previous approaches (proposed: 65.8 %; conventional: 60.2 %), thereby demonstrating the effectiveness of the technique.


Subject(s)
Image Processing, Computer-Assisted , Neural Networks, Computer
13.
Sci Rep ; 11(1): 22012, 2021 11 10.
Article in English | MEDLINE | ID: mdl-34759296

ABSTRACT

Previous studies have found that Autism Spectrum Disorder (ASD) children scored lower during a Go/No-Go task and faced difficulty focusing their gaze on the speaker's face during a conversation. To date, however, there has not been an adequate study examining children's response and gaze during the Go/No-Go task to distinguish ASD from typical children. We investigated typical and ASD children's gaze modulation when they played a version of the Go/No-Go game. The proposed system represents the Go and the No-Go stimuli as chicken and cat characters, respectively. It tracks children's gaze using an eye tracker mounted on the monitor. Statistically significant between-group differences in spatial and auto-regressive temporal gaze-related features for 21 ASD and 31 typical children suggest that ASD children had more unstable gaze modulation during the test. Using the features that differ significantly as inputs, the AdaBoost meta-learning algorithm attained an accuracy rate of 88.6% in differentiating the ASD subjects from the typical ones.


Subject(s)
Attention/physiology , Autism Spectrum Disorder/diagnosis , Fixation, Ocular , Inhibition, Psychological , Algorithms , Autism Spectrum Disorder/psychology , Child, Preschool , Eye-Tracking Technology , Female , Humans , Japan , Male , Psychomotor Performance
14.
Sci Rep ; 11(1): 7324, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33795710

ABSTRACT

There is an urgent need for the development of ways to address the major issue of falls among today's globally aging population. The authors here outline a new approach referred to as virtual light-touch contact to mitigate postural sway during ambulatory and stationary periods, and propose a wearable light-touch (WLT) system featuring a virtual partition around the user that allows determination of virtual forces resulting from related contact. The data produced are used to create vibrotactile fingertip feedback, which supports comprehensive perception of the partition. Non-impaired subjects were recruited to support evaluation of the prototype system (incorporating tactile stimulation and motion-capture technology), with outcomes showing successful mitigation of postural sway in a heel-to-toe tandem stance. Research performed with 150 able-bodied volunteers to validate the performance of the new set-up (incorporating an acceleration sensor and a voice coil motor to render the light-touch effect) suggested that the proposed WLT approach supports human balance on a level comparable to that of the light-touch effect.


Subject(s)
Biomedical Engineering/methods , Postural Balance/physiology , Proprioception/physiology , Touch/physiology , Adult , Aged , Aged, 80 and over , Aging/physiology , Electric Impedance , Fingers/physiology , Humans , Male , Middle Aged , Perception , Posture/physiology , Pressure , Preventive Medicine/methods , Weight-Bearing/physiology , Young Adult
15.
Comput Methods Programs Biomed ; 199: 105838, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33421664

ABSTRACT

BACKGROUND AND OBJECTIVES: The number of preterm babies is steadily growing world-wide and these neonates are at risk of neuro-motor-cognitive deficits. The observation of spontaneous movements in the first three months of age is known to predict such risk. However, the analysis by specifically trained physiotherapists is not suited for the clinical routine, motivating the development of simple computerized video analysis systems, integrated with a well-structured Biobank to make available for preterm babies a growing service with diagnostic, prognostic and epidemiological purposes. METHODS: MIMAS (Markerless Infant Movement Analysis System) is a simple, low-cost system of video analysis of spontaneous movements of newborns in their natural environment, based on a single standard RGB camera, without markers attached to the body. The original videos are transformed into binarized sequences highlighting the silhouette of the baby, in order to minimize the illumination effects and increase the robustness of the analysis; such sequences are then coded by a large set of parameters (39) related to the spatial and spectral changes of the silhouette. The parameter vectors of each baby were stored in the Biobank together with related clinical information. RESULTS: The preliminary test of the system was carried out at the Gaslini Pediatric Hospital in Genoa, where 46 preterm (PT) and 21 full-term (FT) babies (as controls) were recorded at birth (T0) and 8-12 weeks thereafter (T1). A simple statistical analysis of the data showed that the coded parameters are sensitive to the degree of maturation of the newborns (comparing T0 with T1, for both PT and FT babies), and to the conditions at birth (PT vs. FT at T0), whereas this difference tends to vanish at T1. Moreover, the coding method seems also able to detect the few 'abnormal' preterm babies in the PT populations that were analyzed as specific case studies. CONCLUSIONS: Preliminary results motivate the adoption of this tool in clinical practice allowing for a systematic accumulation of cases in the Biobank, thus for improving the accuracy of data analysis performed by MIMAS and ultimately allowing the adoption of data mining techniques.


Subject(s)
Infant, Premature , Movement , Child , Humans , Infant , Infant, Newborn
16.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 3150-3153, 2020 07.
Article in English | MEDLINE | ID: mdl-33018673

ABSTRACT

The purpose of this study is to investigate the effect of changing the application points and directions of the soft actuator band of a wearable hip assist device on muscle force and joint kinematics during gait. Healthy adult participants walked under four conditions with varying band positions of a soft wearable hip assist device. The three-dimensional coordinates of markers and ground reaction force data were measured during gait. Lower limb muscle forces and joint angles were calculated using a musculoskeletal model. Our results showed that the position and running direction of the soft actuator band decreased the forces of the iliopsoas and hamstring muscles.


Subject(s)
Gait , Wearable Electronic Devices , Adult , Biomechanical Phenomena , Humans , Lower Extremity , Walking
17.
Sci Rep ; 10(1): 16827, 2020 10 08.
Article in English | MEDLINE | ID: mdl-33033352

ABSTRACT

Various attempts have been made to elucidate the development patterns in the spontaneous movements of infants through longitudinal evaluations. Movement complexity has been found to demonstrate u-shaped changes in the measurements focusing on limb movements. However, researchers have not yet clarified how other characteristics, besides movement complexity, change over time. This paper presents a longitudinal evaluation of spontaneous movements in infants using evaluation indices calculated through markerless video analysis. Nine infants with corrected ages from [Formula: see text] to 15 weeks participated in the experiments. We confirmed the change in indices over time using statistical methods. Index changes can be classified as positively correlated, u-shaped, inverted u-shaped, and uncorrelated. We also confirmed that the u-shaped and inverted u-shaped indices are negatively correlated. Furthermore, the principal component analysis revealed that the first principal component had the inverted u-shaped changes with the corrected age. These results suggest that it is important to synchronize the inverted u-shaped variations in the movement and velocity with the u-shaped changes in the movement complexity for infant development.


Subject(s)
Child Development/physiology , Infant, Newborn/physiology , Movement , Video Recording/methods , Humans , Infant , Longitudinal Studies , Supine Position/physiology
18.
IEEE Trans Neural Syst Rehabil Eng ; 28(10): 2194-2202, 2020 10.
Article in English | MEDLINE | ID: mdl-32866100

ABSTRACT

An ankle-foot orthosis (AFO) with a plantarflexion resistance function, improves post-stroke gait. An AFO with a plantarflexion resistance function not only affects the first rocker function and the weight acceptance but also the late stance phase. Achilles tendon extension is important for ankle joint function and for forward propulsion during the late stance phase; however, the effect of an AFO with a plantarflexion resistance function on the Achilles tendon is unclear. The purpose of this study was to investigate the effect of plantarflexion resistance on the extension of the Achilles tendon and the forward-propulsive force. Herein, 10 healthy adult males participated who walked under three different conditions: a no-AFO condition and two AFO conditions that had different levels of plantarflexion resistance (P1 and P2). The stiffness value of the P1 and P2 conditions was 0.56 and 1.47 Nm/°, respectively. A three-dimensional (3D) motion analysis system and a musculoskeletal model were used to assess the tendon-length change, the ground reaction force, kinematics, and kinetics data. The change in Achilles tendon length was significantly lower in the P1 and P2 conditions than the no-AFO condition. Furthermore, changes in the length of the Achilles tendon significantly decreased in the P2 condition when compared with that in the P1 condition. The peak anterior ground reaction force was significantly lower in the P2 condition than the no-AFO condition. These results suggest that excessive assist provided by an AFO prevents efficient gait by decreasing both the forward-propulsive force and tendon function.


Subject(s)
Achilles Tendon , Foot Orthoses , Gait Disorders, Neurologic , Stroke Rehabilitation , Adult , Ankle , Ankle Joint , Biomechanical Phenomena , Gait , Humans , Male , Range of Motion, Articular
19.
Sci Rep ; 10(1): 11266, 2020 07 09.
Article in English | MEDLINE | ID: mdl-32647233

ABSTRACT

This study proposes a quantitative evaluation support system for infant motor development and uses the system to analyze hands-and-knees creeping and belly crawling. This system measures movements using two video cameras and extracts movement features via background and inter-frame subtractions of original images. Eight evaluation indices for each crawling cycle are calculated, enabling markerless movement analysis of infants. Cross-sectional analysis of 16 10-month-olds confirmed significant differences between hands-and-knees creeping and belly crawling in five of the eight indices, demonstrating the system capability to quantitatively differentiate between creeping and crawling. Longitudinal analysis of one infant (aged 7-10 months) also suggested that the proposed quantitative indices can follow changes in crawling characteristics and evaluate infants' motor development process. The results from the experiments suggest that the proposed system may enable diagnosis support in clinical practice.


Subject(s)
Child Development , Motor Skills/physiology , Video Recording , Walking/physiology , Calibration , Cross-Sectional Studies , Female , Hand/physiology , Humans , Image Processing, Computer-Assisted , Infant , Knee/physiology , Longitudinal Studies , Male , Movement
20.
Sci Rep ; 10(1): 1422, 2020 01 29.
Article in English | MEDLINE | ID: mdl-31996716

ABSTRACT

General movements (GMs), a type of spontaneous movement, have been used for the early diagnosis of infant disorders. In clinical practice, GMs are visually assessed by qualified licensees; however, this presents a difficulty in terms of quantitative evaluation. Various measurement systems for the quantitative evaluation of GMs track target markers attached to infants; however, these markers may disturb infants' spontaneous movements. This paper proposes a markerless movement measurement and evaluation system for GMs in infants. The proposed system calculates 25 indices related to GMs, including the magnitude and rhythm of movements, by video analysis, that is, by calculating background subtractions and frame differences. Movement classification is performed based on the clinical definition of GMs by using an artificial neural network with a stochastic structure. This supports the assessment of GMs and early diagnoses of disabilities in infants. In a series of experiments, the proposed system is applied to movement evaluation and classification in full-term infants and low-birth-weight infants. The experimental results confirm that the average agreement between four GMs classified by the proposed system and those identified by a licensee reaches up to 83.1 ± 1.84%. In addition, the classification accuracy of normal and abnormal movements reaches 90.2 ± 0.94%.


Subject(s)
Movement Disorders/diagnosis , Movement/physiology , Neurodevelopmental Disorders/diagnosis , Biomarkers , Biomedical Engineering , Female , Humans , Infant , Infant, Low Birth Weight , Male , Models, Theoretical , Motor Activity
SELECTION OF CITATIONS