Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Type of study
Publication year range
1.
R Soc Open Sci ; 6(2): 180657, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30891253

ABSTRACT

Electric fields are widely used for controlling liquids in various research fields. To control a liquid, an alternating current (AC) electric field can offer unique advantages over a direct current (DC) electric field, such as fast and programmable flows and reduced side effects, namely the generation of gas bubbles. Here, we demonstrate one-directional flow along carbon nanotube nanowires under an AC electric field, with no additional equipment or frequency matching. This phenomenon has the following characteristics: First, the flow rates of the transported liquid were changed by altering the frequency showing Gaussian behaviour. Second, a particular frequency generated maximum liquid flow. Third, flow rates with an AC electric field (approximately nanolitre per minute) were much faster than those of a DC electric field (approximately picolitre per minute). Fourth, the flow rates could be controlled by changing the applied voltage, frequency, ion concentration of the solution and offset voltage. Our finding of microfluidic control using an AC electric field could provide a new method for controlling liquids in various research fields.

2.
J Hazard Mater ; 365: 494-501, 2019 03 05.
Article in English | MEDLINE | ID: mdl-30466047

ABSTRACT

Oil spills from disasters such as the sinking of ships and the discharge of oily wastes cause serious environmental problems. Polydimethylsiloxane(PDMS) sponges are valuable tools for isolating spilled oil. Here, we propose new PDMS sponges with bio-inspired design and enhanced absorption capacities. 3D printing was used to produce templates having negative designs, and after being filled with PDMS, the templates were selectively dissolved. Through this, PDMS sponges with well-interconnected and controlled porosities were produced within 10% error. The wettability of sponges with various pore sizes and line widths was investigated. The surfaces were found to be highly hydrophobic, with water contact angles of 100-143°, and oleophilic, with oil contact angles of ∼0°. The sponge fabricated with line width of 200 µm and pore size of 400 µm showed the highest hydrophobicity and oleophilicity. These parameters were used to produce the surfaces of hollow sponges having bio-inspired design that mimics the water absorption and storage functions of cactus. Repeated oil-water separation testing was conducted, and the absorption capacities were compared with those of non-hollow and conventional sponges. The new design showed absorption capacity up to 3.7 times that of the sponges. The bio-inspired PDMS sponge provides a significant advance in oil-water separation ability.

3.
Materials (Basel) ; 11(10)2018 Oct 16.
Article in English | MEDLINE | ID: mdl-30332782

ABSTRACT

Brain‒machine interface (BMI) is a promising technology that looks set to contribute to the development of artificial limbs and new input devices by integrating various recent technological advances, including neural electrodes, wireless communication, signal analysis, and robot control. Neural electrodes are a key technological component of BMI, as they can record the rapid and numerous signals emitted by neurons. To receive stable, consistent, and accurate signals, electrodes are designed in accordance with various templates using diverse materials. With the development of microelectromechanical systems (MEMS) technology, electrodes have become more integrated, and their performance has gradually evolved through surface modification and advances in biotechnology. In this paper, we review the development of the extracellular/intracellular type of in vitro microelectrode array (MEA) to investigate neural interface technology and the penetrating/surface (non-penetrating) type of in vivo electrodes. We briefly examine the history and study the recently developed shapes and various uses of the electrode. Also, electrode materials and surface modification techniques are reviewed to measure high-quality neural signals that can be used in BMI.

4.
Sci Rep ; 8(1): 13581, 2018 Sep 11.
Article in English | MEDLINE | ID: mdl-30206375

ABSTRACT

Transparent conducting electrodes (TCE) are widely used in a variety of applications including displays, light-emitting diodes (LEDS), and solar cells. An important factor in TCE design is active control of the sheet resistance and transparency; as these are inversely proportional, it is essential to develop a technology that can maintain high transparency, while actively controlling sheet resistance, for a range of applications. Here, a nanofiber network was fabricated based on direct electrospinning onto a three-dimensional (3-D) complex substrate; flat metal electrodes without junction resistance were produced using heat treatment and electroless deposition. The fabricated transparent electrode exhibited a transparency of over 90% over the entire visible light range and a sheet resistance of 4.9 ohms/sq. Adhesion between the electrode and substrate was superior to other electrospinning-based transparent electrodes. The performance of the transparent electrode was verified by measurements taken while using the electrode as a heater; a maximum temperature of 210 °C was achieved. The proposed copper nanofiber-based heater electrode offers the advantages of transparency as well as application to complex 3-D surfaces.

5.
Nanoscale Res Lett ; 12(1): 610, 2017 Nov 28.
Article in English | MEDLINE | ID: mdl-29185132

ABSTRACT

We report a simple method for electrospinning polymers onto flexible, insulating substrates by controlling the wettability of the substrate surface. Water molecules were adsorbed onto the surface of a hydrophilic polymer substrate by increasing the local humidity around the substrate. The adsorbed water was used as the ground electrode for electrospinning. The electrospun fibers were deposited only onto hydrophilic areas of the substrate, allowing for patterning through wettability control. Direct writing of polymer fiber was also possible through near-field electrospinning onto a hydrophilic surface.

6.
Polymers (Basel) ; 9(8)2017 Jul 25.
Article in English | MEDLINE | ID: mdl-30970981

ABSTRACT

Wearable human interaction devices are technologies with various applications for improving human comfort, convenience and security and for monitoring health conditions. Healthcare monitoring includes caring for the welfare of every person, which includes early diagnosis of diseases, real-time monitoring of the effects of treatment, therapy, and the general monitoring of the conditions of people's health. As a result, wearable electronic devices are receiving greater attention because of their facile interaction with the human body, such as monitoring heart rate, wrist pulse, motion, blood pressure, intraocular pressure, and other health-related conditions. In this paper, various smart sensors and wireless systems are reviewed, the current state of research related to such systems is reported, and their detection mechanisms are compared. Our focus was limited to wearable and attachable sensors. Section 1 presents the various smart sensors. In Section 2, we describe multiplexed sensors that can monitor several physiological signals simultaneously. Section 3 provides a discussion about short-range wireless systems including bluetooth, near field communication (NFC), and resonance antenna systems for wearable electronic devices.

7.
Nanoscale Res Lett ; 11(1): 385, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27581602

ABSTRACT

Carbon nanotube (CNT) nanobundles are widely used in nanoscale imaging, fabrication, and electrochemical and biological sensing. The diameter of CNT nanobundles should be controlled precisely, because it is an important factor in determining electrode performance. Here, we fabricated CNT nanobundles on tungsten tips using dielectrophoresis (DEP) force and controlled their diameters by varying the withdrawal velocity of the tungsten tips. Withdrawal velocity pulling away from the liquid-air interface could be an important, reliable parameter to control the diameter of CNT nanobundles. The withdrawal velocity was controlled automatically and precisely with a one-dimensional motorized stage. The effect of the withdrawal velocity on the diameter of CNT nanobundles was analyzed theoretically and compared with the experimental results. Based on the attachment efficiency, the withdrawal velocity is inversely proportional to the diameter of the CNT nanobundles; this has been demonstrated experimentally. Control of the withdrawal velocity will play an important role in fabricating CNT nanobundles using DEP phenomena.

9.
Sci Rep ; 5: 11799, 2015 Jul 02.
Article in English | MEDLINE | ID: mdl-26135840

ABSTRACT

Liquid pumping can occur along the outer surface of an electrode under a DC electric field. For biological applications, a better understanding of the ionic solution pumping mechanism is required. Here, we fabricated CNT wire electrodes (CWEs) and tungsten wire electrodes (TWEs) of various diameters to assess an ionic solution pumping. A DC electric field created by a bias of several volts pumped the ionic solution in the direction of the negatively biased electrode. The resulting electro-osmotic flow was attributed to the movement of an electric double layer near the electrode, and the flow rates along the CWEs were on the order of picoliters per minute. According to electric field analysis, the z-directional electric field around the meniscus of the small electrode was more concentrated than that of the larger electrode. Thus, the pumping effect increased as the electrode diameter decreased. Interestingly in CWEs, the initiating voltage for liquid pumping did not change with increasing diameter, up to 20 µm. We classified into three pumping zones, according to the initiating voltage and faradaic reaction. Liquid pumping using the CWEs could provide a new method for biological studies with adoptable flow rates and a larger 'Recommended pumping zone'.

10.
Adv Healthc Mater ; 3(2): 245-52, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23950033

ABSTRACT

Microelectrodes are widely used for monitoring neural activities in various neurobiological studies. The size of the neural electrode is an important factor in determining the signal-to-noise ratio (SNR) of recorded neural signals and, thereby, the recording sensitivity. Here, it is demonstrated that commercial tungsten microelectrodes can be modified with carbon nanotubes (CNTs), resulting in a highly sensitive recording ability. The impedance with the respect to surface area of the CNT-modified electrodes (CNEs) is much less than that of tungsten microelectrodes because of their large electrochemical surface area (ESA). In addition, the noise level of neural signals recorded by CNEs is significantly less. Thus, the SNR is greater than that obtained using tungsten microelectrodes. Importantly, when applied in a mouse brain in vivo, the CNEs can detect action potentials five times more efficiently than tungsten microelectrodes. This technique provides a significant advance in the recording of neural signals, especially in brain regions with sparse neuronal densities.


Subject(s)
Electrodes , Nanotubes, Carbon/chemistry , Cells, Cultured , Humans , Neurons/physiology , Tungsten/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...