Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
JMIR Res Protoc ; 13: e55452, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38713508

ABSTRACT

BACKGROUND: Physical capacity and physical activity are important aspects of physical functioning and quality of life in people with a chronic disease such as Parkinson disease (PD) or chronic obstructive pulmonary disease (COPD). Both physical capacity and physical activity are currently measured in the clinic using standardized questionnaires and tests, such as the 6-minute walk test (6MWT) and the Timed Up and Go test (TUG). However, relying only on in-clinic tests is suboptimal since they offer limited information on how a person functions in daily life and how functioning fluctuates throughout the day. Wearable sensor technology may offer a solution that enables us to better understand true physical functioning in daily life. OBJECTIVE: We aim to study whether device-assisted versions of 6MWT and TUG, such that the tests can be performed independently at home using a smartwatch, is a valid and reliable way to measure the performance compared to a supervised, in-clinic test. METHODS: This is a decentralized, prospective, observational study including 100 people with PD and 100 with COPD. The inclusion criteria are broad: age ≥18 years, able to walk independently, and no co-occurrence of PD and COPD. Participants are followed for 15 weeks with 4 in-clinic visits, once every 5 weeks. Outcomes include several walking tests, cognitive tests, and disease-specific questionnaires accompanied by data collection using wearable devices (the Verily Study Watch and Modus StepWatch). Additionally, during the last 10 weeks of this study, participants will follow an aerobic exercise training program aiming to increase physical capacity, creating the opportunity to study the responsiveness of the remote 6MWT. RESULTS: In total, 89 people with PD and 65 people with COPD were included in this study. Data analysis will start in April 2024. CONCLUSIONS: The results of this study will provide information on the measurement properties of the device-assisted 6MWT and TUG in the clinic and at home. When reliable and valid, this can contribute to a better understanding of a person's physical capacity in real life, which makes it possible to personalize treatment options. TRIAL REGISTRATION: ClinicalTrials.gov NCT05756075; https://clinicaltrials.gov/study/NCT05756075. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/55452.


Subject(s)
Parkinson Disease , Pulmonary Disease, Chronic Obstructive , Wearable Electronic Devices , Humans , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/psychology , Parkinson Disease/physiopathology , Parkinson Disease/diagnosis , Prospective Studies , Male , Aged , Female , Walk Test/methods , Middle Aged , Observational Studies as Topic , Physical Functional Performance , Quality of Life
2.
Elife ; 132024 Apr 18.
Article in English | MEDLINE | ID: mdl-38635312

ABSTRACT

Complex skills like speech and dance are composed of ordered sequences of simpler elements, but the neuronal basis for the syntactic ordering of actions is poorly understood. Birdsong is a learned vocal behavior composed of syntactically ordered syllables, controlled in part by the songbird premotor nucleus HVC (proper name). Here, we test whether one of HVC's recurrent inputs, mMAN (medial magnocellular nucleus of the anterior nidopallium), contributes to sequencing in adult male Bengalese finches (Lonchura striata domestica). Bengalese finch song includes several patterns: (1) chunks, comprising stereotyped syllable sequences; (2) branch points, where a given syllable can be followed probabilistically by multiple syllables; and (3) repeat phrases, where individual syllables are repeated variable numbers of times. We found that following bilateral lesions of mMAN, acoustic structure of syllables remained largely intact, but sequencing became more variable, as evidenced by 'breaks' in previously stereotyped chunks, increased uncertainty at branch points, and increased variability in repeat numbers. Our results show that mMAN contributes to the variable sequencing of vocal elements in Bengalese finch song and demonstrate the influence of recurrent projections to HVC. Furthermore, they highlight the utility of species with complex syntax in investigating neuronal control of ordered sequences.


Subject(s)
Songbirds , Male , Animals , Speech , Acoustics , Memory , Stereotyped Behavior
3.
J Card Fail ; 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38582256

ABSTRACT

BACKGROUND: Data collected via wearables may complement in-clinic assessments to monitor subclinical heart failure (HF). OBJECTIVES: Evaluate the association of sensor-based digital walking measures with HF stage and characterize their correlation with in-clinic measures of physical performance, cardiac function and participant reported outcomes (PROs) in individuals with early HF. METHODS: The analyzable cohort included participants from the Project Baseline Health Study (PBHS) with HF stage 0, A, or B, or adaptive remodeling phenotype (without risk factors but with mild echocardiographic change, termed RF-/ECHO+) (based on available first-visit in-clinic test and echocardiogram results) and with sufficient sensor data. We computed daily values per participant for 18 digital walking measures, comparing HF subgroups vs stage 0 using multinomial logistic regression and characterizing associations with in-clinic measures and PROs with Spearman's correlation coefficients, adjusting all analyses for confounders. RESULTS: In the analyzable cohort (N=1265; 50.6% of the PBHS cohort), one standard deviation decreases in 17/18 walking measures were associated with greater likelihood for stage-B HF (multivariable-adjusted odds ratios [ORs] vs stage 0 ranging from 1.18-2.10), or A (ORs vs stage 0, 1.07-1.45), and lower likelihood for RF-/ECHO+ (ORs vs stage 0, 0.80-0.93). Peak 30-minute pace demonstrated the strongest associations with stage B (OR vs stage 0=2.10; 95% CI:1.74-2.53) and A (OR vs stage 0=1.43; 95% CI:1.23-1.66). Decreases in 13/18 measures were associated with greater likelihood for stage-B HF vs stage A. Strength of correlation with physical performance tests, echocardiographic cardiac-remodeling and dysfunction indices and PROs was greatest in stage B, then A, and lowest for 0. CONCLUSIONS: Digital measures of walking captured by wearable sensors could complement clinic-based testing to identify and monitor pre-symptomatic HF.

4.
JMIR Hum Factors ; 10: e48270, 2023 Aug 03.
Article in English | MEDLINE | ID: mdl-37535417

ABSTRACT

BACKGROUND: Mobility is a meaningful aspect of an individual's health whose quantification can provide clinical insights. Wearable sensor technology can quantify walking behaviors (a key aspect of mobility) through continuous passive monitoring. OBJECTIVE: Our objective was to characterize the analytical performance (accuracy and reliability) of a suite of digital measures of walking behaviors as critical aspects in the practical implementation of digital measures into clinical studies. METHODS: We collected data from a wrist-worn device (the Verily Study Watch) worn for multiple days by a cohort of volunteer participants without a history of gait or walking impairment in a real-world setting. On the basis of step measurements computed in 10-second epochs from sensor data, we generated individual daily aggregates (participant-days) to derive a suite of measures of walking: step count, walking bout duration, number of total walking bouts, number of long walking bouts, number of short walking bouts, peak 30-minute walking cadence, and peak 30-minute walking pace. To characterize the accuracy of the measures, we examined agreement with truth labels generated by a concurrent, ankle-worn, reference device (Modus StepWatch 4) with known low error, calculating the following metrics: intraclass correlation coefficient (ICC), Pearson r coefficient, mean error, and mean absolute error. To characterize the reliability, we developed a novel approach to identify the time to reach a reliable readout (time to reliability) for each measure. This was accomplished by computing mean values over aggregation scopes ranging from 1 to 30 days and analyzing test-retest reliability based on ICCs between adjacent (nonoverlapping) time windows for each measure. RESULTS: In the accuracy characterization, we collected data for a total of 162 participant-days from a testing cohort (n=35 participants; median observation time 5 days). Agreement with the reference device-based readouts in the testing subcohort (n=35) for the 8 measurements under evaluation, as reflected by ICCs, ranged between 0.7 and 0.9; Pearson r values were all greater than 0.75, and all reached statistical significance (P<.001). For the time-to-reliability characterization, we collected data for a total of 15,120 participant-days (overall cohort N=234; median observation time 119 days). All digital measures achieved an ICC between adjacent readouts of >0.75 by 16 days of wear time. CONCLUSIONS: We characterized the accuracy and reliability of a suite of digital measures that provides comprehensive information about walking behaviors in real-world settings. These results, which report the level of agreement with high-accuracy reference labels and the time duration required to establish reliable measure readouts, can guide the practical implementation of these measures into clinical studies. Well-characterized tools to quantify walking behaviors in research contexts can provide valuable clinical information about general population cohorts and patients with specific conditions.

5.
Article in English | MEDLINE | ID: mdl-33362946

ABSTRACT

Background: Non-invasive peripheral nerve stimulation, also referred to as transcutaneous afferent patterned stimulation (TAPS), reduces hand tremor in essential tremor (ET) subjects. However, the mechanism of action of TAPS is unknown. Here, we investigated changes in brain metabolism over three months of TAPS use in ET subjects. Methods: This was an interventional, open label, single group study enrolling 5 ET subjects. They received 40 minutes of TAPS treatment twice daily for 90 days. Brain metabolic activity and tremor severity were measured using 18F-fluorodeoxyglucose (FDG) PET/CT, and the Tremor Research Group Essential Tremor Rating Assessment Scale (TETRAS), respectively, at baseline and after 90 days. Tremor power and frequency was measured before and after all TAPS sessions using an onboard three-axis accelerometer. Results: FDG PET/CT revealed areas of hypermetabolism in ipsilateral cerebellar hemisphere and hypometabolism in contralateral cerebellar hemisphere following 90 days of TAPS treatment, compared to day one (uncorrected p value <0.05). Paired pre-post kinematic measurements over 90 days showed significantly decreased tremor power (p < 0.0001) but no change in tremor frequency. The TETRAS score on day 1 decreased from 6.5 ± 2.5 to 4.1 ± 1.8 following TAPS (p = 0.05). The pre-post TETRAS scores on day 90: 4.9 ± 1.5 and 4.1± 1 were lower than pre-TAPS TETRAS score on day 1 (p = 0.14 and 0.05, respectively). Conclusions: Our results suggest that longitudinal TAPS of the median and radial nerves modulates brain metabolism in areas instrumental to motor coordination and implicated in ET. Clinically, TAPS reduced tremor power, but had no effect on tremor frequency. This study paves the way for comprehensive studies in larger cohorts to further elucidate the mechanism of TAPS. Highlights: Non-invasive peripheral nerve stimulation, also referred to as transcutaneous afferent patterned stimulation (TAPS), reduces hand tremor in essential tremor subjects. Longitudinal TAPS therapy alters cerebellar metabolism, which can be a cause or consequence of tremor reduction. Cerebellar-premotor region connectivity may play a role in the anti-tremor effects of TAPS.


Subject(s)
Cerebellum/diagnostic imaging , Electric Stimulation Therapy/methods , Essential Tremor/therapy , Median Nerve , Radial Nerve , Afferent Pathways , Aged , Brain/diagnostic imaging , Brain/metabolism , Cerebellum/metabolism , Essential Tremor/diagnostic imaging , Essential Tremor/metabolism , Female , Fluorodeoxyglucose F18 , Hand , Humans , Male , Middle Aged , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Treatment Outcome
6.
Front Neurosci ; 14: 530300, 2020.
Article in English | MEDLINE | ID: mdl-33281539

ABSTRACT

Essential tremor (ET) patients often experience hand tremor that impairs daily activities. Non-invasive electrical stimulation of median and radial nerves in the wrist using a recently developed therapy called transcutaneous afferent patterned stimulation (TAPS) has been shown to provide symptomatic tremor relief in ET patients and improve patients' ability to perform functional tasks, but the duration of tremor reduction is unknown. In this single-arm, open-label study, fifteen ET patients performed four hand tremor-specific tasks (postural hold, spiral drawing, finger-to-nose reach, and pouring) from the Fahn-Tolosa-Marin Clinical Rating Scale (FTM-CRS) prior to, during, and 0, 30, and 60 min following TAPS. At each time point, tremor severity was visually rated according to the FTM-CRS and simultaneously measured by wrist-worn accelerometers. The duration of tremor reduction was assessed using (1) improvement in the mean FTM-CRS score across all four tasks relative to baseline, and (2) reduction in accelerometer-measured tremor power relative to baseline for each task. Patients were labeled as having at least 60 min of therapeutic benefit from TAPS with respect to each specified metric if all three (i.e., 0, 30, and 60 min) post-therapy measurements were better than that metric's baseline value. The mean FTM-CRS scores improved for at least 60 min beyond the end of TAPS for 80% (12 of 15, p = 4.6e-9) of patients. Similarly, for each assessed task, tremor power improved for at least 60 min beyond the end of TAPS for over 70% of patients. The postural hold task had the largest reduction in tremor power (median 5.9-fold peak reduction in tremor power) and had at least 60 min of improvement relative to baseline beyond the end of TAPS therapy for 73% (11 of 15, p = 9.8e-8) of patients. Clinical ratings of tremor severity were correlated to simultaneously recorded accelerometer-measured tremor power (r = 0.33-0.76 across the four tasks), suggesting tremor power is a valid, objective tremor assessment metric that can be used to track tremor symptoms outside the clinic. These results suggest TAPS can provide reductions in upper limb tremor symptoms for at least 1 h post-therapy in some patients, which may improve patients' ability to perform tasks of daily living.

7.
J Neurophysiol ; 108(8): 2144-59, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22815407

ABSTRACT

Our percept of visual stability across saccadic eye movements may be mediated by presaccadic remapping. Just before a saccade, neurons that remap become visually responsive at a future field (FF), which anticipates the saccade vector. Hence, the neurons use corollary discharge of saccades. Many of the neurons also decrease their response at the receptive field (RF). Presaccadic remapping occurs in several brain areas including the frontal eye field (FEF), which receives corollary discharge of saccades in its layer IV from a collicular-thalamic pathway. We studied, at two levels, the microcircuitry of remapping in the FEF. At the laminar level, we compared remapping between layers IV and V. At the cellular level, we compared remapping between different neuron types of layer IV. In the FEF in four monkeys (Macaca mulatta), we identified 27 layer IV neurons with orthodromic stimulation and 57 layer V neurons with antidromic stimulation from the superior colliculus. With the use of established criteria, we classified the layer IV neurons as putative excitatory (n = 11), putative inhibitory (n = 12), or ambiguous (n = 4). We found that just before a saccade, putative excitatory neurons increased their visual response at the RF, putative inhibitory neurons showed no change, and ambiguous neurons increased their visual response at the FF. None of the neurons showed presaccadic visual changes at both RF and FF. In contrast, neurons in layer V showed full remapping (at both the RF and FF). Our data suggest that elemental signals for remapping are distributed across neuron types in early cortical processing and combined in later stages of cortical microcircuitry.


Subject(s)
Evoked Potentials, Visual , Neurons/physiology , Saccades/physiology , Visual Cortex/physiology , Visual Fields , Animals , Macaca mulatta , Male , Neurons/classification , Visual Cortex/cytology , Visual Pathways/physiology
8.
J Neurophysiol ; 103(4): 1874-87, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20107133

ABSTRACT

The basal ganglia are a subcortical assembly of nuclei involved in many aspects of behavior. Three of the nuclei have high firing rates and inhibitory influences: the substantia nigra pars reticulata (SNr), globus pallidus interna (GPi), and globus pallidus externa (GPe). The SNr contains a wide range of visual, cognitive, and motor signals that have been shown to contribute to saccadic eye movements. Our hypothesis was that GPe and GPi neurons carry similarly diverse signals during saccadic behavior. We recorded from GPe, GPi, and SNr neurons in monkeys that made memory-guided saccades and found that neurons in all three structures had increases or decreases in activity synchronized with saccade generation, visual stimulation, or reward. Comparing GPe neurons with GPi neurons, we found relatively more visual-related activity in GPe and more reward-related activity in GPi. Comparing both pallidal samples with the SNr, we found a greater resemblance between GPe and SNr neurons than that between GPi and SNr neurons. As expected from a known inhibitory projection from GPe to SNr, there was a general reversal of sign in activity modulations between the structures: bursts of activity were relatively more common in GPe and pauses more common in SNr. We analyzed the response fields of neurons in all three structures and found relatively narrow and lateralized fields early in trials (during visual and saccadic events) followed by a broadening later in trials (during reward). Our data reinforce an emerging, new consensus that the GPe and GPi, in addition to the SNr, contribute to oculomotor behavior.


Subject(s)
Behavior, Animal/physiology , Globus Pallidus/physiology , Macaca mulatta/physiology , Oculomotor Muscles/physiology , Sensory Receptor Cells/physiology , Substantia Nigra/physiology , Animals , Cognition/physiology , Eye Movements/physiology , Magnetic Resonance Imaging , Models, Animal , Motor Activity/physiology , Photic Stimulation
SELECTION OF CITATIONS
SEARCH DETAIL
...