Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38697214

ABSTRACT

BACKGROUND: Since the primary goal of cleft lip repair is to achieve a symmetrical, aesthetic lip, several surgical techniques have been utilized. Accordingly, in this study, a unilateral cleft lip was surgically repaired using two techniques: modified Millard's and Fisher's techniques. PURPOSE: This study was designed to compare the vermillion symmetry and scar quality in the surgical management of patients with unilateral incomplete cleft lip using the modified Millard's and Fisher's techniques. STUDY DESIGN, SETTING, AND SAMPLE: We conducted a prospective randomized controlled clinical study. The study involved 20 patients selected from the Department of Plastic Pediatric Surgery at the Specialized Pediatric Hospital, Faculty of Medicine, Cairo University. The patients included in the study were aged between 2 and 6 months old, had a primary nonsyndromic unilateral incomplete cleft lip, and had no other associated anomalies. PREDICTOR VARIABLE: The predictor variable was operative management of the cleft lip, and subjects were randomly assigned to either the modified Millard or Fisher techniques. MAIN OUTCOME VARIABLES: The primary outcome, vermillion symmetry, was evaluated by computerized photogrammetric lip analysis with Image J software. Additionally, scar quality, considered a secondary outcome, was assessed with the Vancouver Scar Scale and the Image J software. Every measurement was meticulously recorded in millimeters. COVARIATES: Age, sex, and cleft side were considered. ANALYSES: Descriptive and analytic statistics were computed. Statistical significance was set at P < .05. RESULTS: The study comprised 20 children (12 males and 8 females), with a mean age of 140.5 ± 23.7 days in the Fisher's group and 137.4 ± 25.6 days in the modified Millard's group (P = .8). No statistically significant differences (P = .6) were found in vermillion height and width between both groups at 1 week, 3 months, and 6 months. Similarly, there were no statistically significant differences (P = .4) between both groups in terms of scar length and width at the 3- and 6-month follow-up periods. CONCLUSION AND RELEVANCE: This study found no statistically significant differences in vermillion symmetry and scar quality between the two cleft lip repair techniques. Notably, one patient in the modified Millard group exhibited a notch on the vermillion border, which was not statistically significant.

2.
BMC Cancer ; 22(1): 1252, 2022 Dec 02.
Article in English | MEDLINE | ID: mdl-36460978

ABSTRACT

BACKGROUND: Reconstruction of mandibular defects following ablative surgery remains a challenge even for experienced surgeons. Virtual planning and guided surgery, including computer-aided design/computer-aided manufacturing (CAD/CAM), afford optimized ways by which to plan complex surgery. This study aimed to evaluate and compare aesthetic outcome and surgical efficiency of free fibular flap (FFF) with and without CAD/CAM customized osteotomy guide (COG) for reconstruction of onco-surgical mandibular defects. METHODS: Twenty-two patients indicated for segmental mandibulectomy were randomly assigned to either CAD/CAM with COG group or that without COG- Model based reconstruction (MB group) at a 1:1 ratio. Aesthetic outcomes were evaluated by means of morphometric assessment and comparison for each differential area (DAr) and angle (DAn) in the affected side to the contralateral side of the mandible using computerized digital imaging analysis (CDIA) based on the post-operative 3D CT-scan. Subjective evaluation was performed using the Visual Analogue Scale (VAS) and Patient's Satisfaction Score (PSS). Surgical efficiency was a secondary outcome and evaluated as total operative time and ischemia time. RESULTS: The mean sagittal DAr was significantly lower in the COG group (277.28 ± 127.05 vs. 398.67 ± 139.10 mm2, P = 0.045). Although there was an improvement in the axial DAr (147.61 ± 55.42 vs. 183.68 ± 72.85 mm2), the difference was not statistically significant (P = 0.206). The mean differences (Δ) in both sagittal and coronal DAn were significantly lower in the COG group than in the MB group (6.11 ± 3.46 and 1.77 ± 1.12° vs. 9.53 ± 4.17 and 3.44 ± 2.34°), respectively. There were no statistically significant differences in the axial DAn between the two groups (P = 0.386). The PSS was significantly higher in the COG group, reflecting better aesthetic satisfaction than in the MB group (P = 0.041). The total operation and ischemia time were significantly shorter in favor of the COG group with a mean of (562.91 ± 51.22, 97.55 ± 16.80 min vs. 663.55 ± 53.43, 172.45 ± 21.87 min), respectively. CONCLUSION: The CAD/CAM with COG is more reliable and highly valuable in enhancing aesthetic outcomes and surgical efficiency of mandibular reconstruction by FFF compared to that without COG (MB reconstruction). TRIAL REGISTRATION: This trial was registered at ClinicalTrials.gov . REGISTRATION NUMBER: NCT03757273. Registration date: 28/11/2018.


Subject(s)
Computer-Aided Design , Mandible , Humans , Mandible/surgery , Esthetics , Ischemia , Osteotomy
3.
BMC Surg ; 22(1): 362, 2022 Oct 19.
Article in English | MEDLINE | ID: mdl-36261822

ABSTRACT

BACKGROUND: Reconstruction of the maxillary defects following tumor ablation remains to be a challenge for surgeons. Virtual surgical planning (VSP), intraoperative cutting guides and stereolithographic models provides the head and neck reconstructive surgeon with powerful tools for complex reconstruction planning. Despite its use in fibular osteocutaneous reconstruction, application to the scapular free flap has not been as widely reported. The aim of this study was to compare aesthetic results and operation time of free scapular flap, with and without computer-aided design and computer-aided manufacturing (CAD/CAM) customized osteotomy guide, for reconstruction of maxillary defects. METHODS: In this prospective randomized controlled clinical trial study, we randomly assigned 22 patients with maxillary defects who were scheduled to undergo maxillary reconstruction with either free scapular flap with CAD/CAM customized osteotomy guide; study group (n = 11) or free scapular flap without CAD/CAM customized osteotomy guide; control group (n = 11). All patients were followed up for 3 months. The aesthetic outcome, operation and ischemic times were evaluated and compared. RESULTS: Aesthetic outcomes were evaluated objectively by means of differential surface area (sagittal and axial) measurement, which showed improved aesthetic outcome (contour symmetry) in the study group with a mean of (241.39 ± 113.74 mm2), compared to patients in control group with a mean of (358.70 ± 143.99 mm2). There were significant differences between the two groups (P < 0.05). Aesthetic outcomes were also evaluated subjectively by means of visual analogue scale (VAS) and patient's satisfaction score (PSS). The postoperative aesthetic appearance was better in the study group with more patients satisfied than that in control group and there were statistically significant differences (P = 0.039). The mean total operative time was 678.81 min and 777.18 min in the study group and control group respectively (P < 0.05) and the mean ischemia time was 133.18 min and 195.72 min for study group and control group respectively (P < 0.05). The ischemia time and total operative time were shorter in the study group compared to those in the control group and there were no flap losses in both groups. CONCLUSION: The use of CAD/CAM prefabricated cutting guides facilitates scapular flap molding and placement, minimizes ischemic time and operating time as well as improves aesthetic outcomes. Trial registration This trial was registered at ClinicalTrials.gov. REGISTRATION NUMBER: NCT03757286. Registration date: 28/11/2018.


Subject(s)
Maxillary Neoplasms , Plastic Surgery Procedures , Humans , Computer-Aided Design , Esthetics , Ischemia , Osteotomy , Plastic Surgery Procedures/methods , Surgery, Computer-Assisted , Surgical Flaps , Prospective Studies , Maxillary Neoplasms/surgery
4.
Craniomaxillofac Trauma Reconstr ; 10(2): 151-158, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28523089

ABSTRACT

We report a case of complete dislocation of the globe into the maxillary sinus, with immediate repositioning of the globe. This report highlights the importance of early surgical repair of orbital fracture and globe repositioning to regain the maximum amount of ocular functions. A review of literature found 19 cases of globe dislocation into the maxillary sinus: One case was enucleated 2 months after misdiagnosis as traumatic enucleation, six cases were documented no vision or no light perception, three cases did not have reported vision (patients did not survive), and nine cases with postoperative vision. We recommend early surgical intervention to restore the cosmetic and visual function of the dislocated eye.

SELECTION OF CITATIONS
SEARCH DETAIL
...