ABSTRACT
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17 and 18 K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90 to 240 Hz by cooling the mirrors. The improved sensitivity reached a maximum of 2.2×10(-19) m/âHz at 165 Hz.
ABSTRACT
We evaluated the performance of polished mirror surfaces for the TAMA interferometric gravitational wave detector by comparing the experimental results with a wave-front tracing simulation. The TAMA mirror surfaces were polished to a roughness of a few nanometer rms. We confirmed that these polished mirrors do not limit the present TAMA sensitivity and that the target shot-noise sensitivity will be achieved with these mirrors, even if a power-recycling technique is introduced in the next stage of the TAMA.