Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Publication year range
1.
Gan To Kagaku Ryoho ; 36(8): 1341-5, 2009 Aug.
Article in Japanese | MEDLINE | ID: mdl-19692775

ABSTRACT

We experienced a case in which the hepatic artery catheter system could be used long term. Even after 5 years and five months, there was no damage to the hepatic artery, and we could still use this system. For insertion of the catheter, a fine catheter with the tip tapered at 2.7 F was selected. This catheter was inserted into the hepatic artery peripheral branch in the liver, after a side hole was created 11 cm from the tip, and the side hole was adjusted to stay in the common hepatic artery. We speculated that the reason for little injury to the hepatic artery was use of a fine catheter despite possible damage to the hepatic artery wall like saw cutting in this case. We classified the patterns according to which a catheter damaged the inner wall of the hepatic artery into 5: "straight punch type", "hook punch type", "whiplash type", "elbow blow type", "and saw type".


Subject(s)
Catheterization , Hepatic Artery , Infusions, Intra-Arterial , Hepatic Artery/pathology , Humans , Infusions, Intra-Arterial/instrumentation , Liver Neoplasms/drug therapy , Male , Middle Aged , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...