Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Cancers (Basel) ; 13(21)2021 Nov 04.
Article in English | MEDLINE | ID: mdl-34771706

ABSTRACT

Urine-based biomarkers have shown suitable diagnostic potential for prostate cancer (PCa) detection. Yet, until now, prostatic massage remains required prior to urine sampling. Here, we test a potential diagnostic approach using voided urine collected without prior digital rectal examination (DRE). In this study, we evaluated the diagnostic performance of a microfluidic-based platform that combines the principle of photodynamic diagnostic with immunocapture for the detection of PCa cells. The functionality and sensitivity of this platform were validated using both cultured cells and PCa patient urine samples. Quantitative reverse-transcriptase polymerase chain reaction (qRT-PCR) demonstrated this platform had a detection limit of fewer than 10 cells per 60 µL and successfully validated the presence of a PCa biomarker in the urine of cancer patients without prior DRE. This biosensing platform exhibits a sensitivity of 72.4% and a specificity of 71.4%, in suitable agreement with qRT-PCR data. The results of this study constitute a stepping stone in the future development of noninvasive prostate cancer diagnostic technologies that do not require DRE.

2.
Biointerphases ; 15(3): 031002, 2020 05 15.
Article in English | MEDLINE | ID: mdl-32414237

ABSTRACT

Prostate cancer is the second most common cancer in men and the second leading cause of male cancer deaths. The current blood test for detecting prostate cancers measures prostate-specific antigen. It has many limitations including a very high rate of false positives. Herein, prostate-specific membrane antigen (PSMA) based immunocapture and hexaminolevulinate (HAL) based photodetection are integrated into a new diagnostic device designed to selectively identify whole prostate cancer cells from voided urine with the aim of providing an accurate noninvasive alternative to current diagnosis methods. Prestained, prostate cancer cells spiked in urine samples at concentrations ranging from 1500 to 2000 cells/ml were captured with 89% sensitivity and 95% specificity. HAL, a cancer specific photosensitizer, was then used to circumvent the need for prestaining. Optimum HAL incubation conditions were identified (50 µM at 37 °C for 2 h) where the mean HAL-induced fluorescence intensity of LNCaP cells was three times that of healthy PNT2 cells, thus providing an independent way to discriminate captured cancer cells from background metabolites. Combining anti-PSMA immunocapture with HAL-induced fluorescent detection, 86% sensitivity and 88% selectivity were achieved, thereby proving the validity of the dual-method for the selective photospecific detection of prostate cancer cells.


Subject(s)
Photochemotherapy/instrumentation , Plasma Gases/chemistry , Prostatic Neoplasms/pathology , Aminolevulinic Acid/analogs & derivatives , Aminolevulinic Acid/chemistry , Cell Count , Cell Line, Tumor , Cell Nucleus/metabolism , Fluorescence , Humans , Male , Microfluidics , Prostatic Neoplasms/urine , Sensitivity and Specificity , Temperature , Time Factors
3.
Photodiagnosis Photodyn Ther ; 28: 238-247, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31394301

ABSTRACT

Exogenous administration of the photodynamic agent hexaminolevulinate induces Protoporphyrin IX (PpIX) accumulation in malignant tissue. This may enable differentiation from healthy tissues by emission of a distinctive red fluorescence. It provides the photo-specific detection when excited with blue light at 405 nm. This study determines the ex-vivo processing conditions (time, concentration, temperature and addition of a fluorescent dye) required for HAL-induced PpIX fluorescence to successfully discriminate between bladder cancer and benign fibroblast cells shed in urine at the single cell level. HAL-induced fluorescence was 4.5 times brighter in cancer cells than non-cancer cells when incubated in the optimum conditions, and could be used to correctly identified bladder cancer cells captured within a newly developed immunofunctionalized biosensor with 88% efficiency. This biosensor is designed to facilitate the immuno-capture of cancer cells by interaction with carcinoma specific anti Epithelial Cell Adhesion molecule (anti-EpCAM) antibodies. Anti-EpCAM antibodies were immobilized on polyoxazoline (POx) plasma polymers by covalent bonds in microfluidic channels. Combining photodynamic and immunoselective approach therefore constitute a promising approach for the non-invasive diagnosis of bladder cancer with two independent level of confidence. OBJECTIVE: This study investigate the relationship between different regulatory factors (time, concentration, temperature and addition of a fluorescent dye) and Hexaminolevulinate (HAL)-mediated photodynamic diagnosis of bladder cancer (PDD) in vitro. We examine the natural photosensitizer Protoporphyrin IX (PpIX) fluorescence induced by HAL in several human bladder cancer cell lines and one non-cancer foreskin fibroblast cell line and identify the processing conditions that maximise the difference in fluorescence intensity between malign and benign cell types. The detection of HAL induced fluorescence at a single cell level by a selective cancer cell capture platform is also tested. MATERIALS AND METHODS: Experiments were performed on cultured monolayer cells and cells in suspension. The cell lines examined included the transitional epithelium carcinoma cell lines HT1197, HT1376, EJ138 and RT4, and the non-cancer foreskin fibroblasts HFF. Cells were incubated with HAL in various doses, time and temperature settings. We also used the nuclear red as a tool to study the PpIX subcellular localization. PpIX fluorescence intensities were measured and analysed using fluorescence microscope software. Finally, we evaluated the possibility of using HAL to discriminate between cancer and non-cancer cells from a mixed cell population using a newly developed immunofunctionalized microfluidic platform. RESULTS: The accumulation of PpIX in bladder cancer cells was significantly higher than in non-cancer cells, both cultured monolayer cells and cells in suspension. Effectively, the fluorescence intensity was 4.5 times brighter in bladder cancer cells than non-cancer foreskin fibroblast cells when incubated in the optimum condition, in which the nuclear stain adjuvant acted as a fluorescence enhancer. Cancer cells displayed PpIX accumulated mainly in mitochondria but none or very little PpIX was observed in non-cancer cells. HAL-induced fluorescence could be used to correctly identify bladder cancer cells within the EpCAM conjugated POx based microfluidic sensor with an 88% capture selectivity rate. CONCLUSIONS: These findings prove that the application of HAL-induced PpIX fluorescence can successfully distinguish between cancer and non-cancer cells in vitro. This test can provide advanced second level of confidence on the cancerous nature of cells captured by the immunofunctionalized bladder cancer diagnostic platform.


Subject(s)
Aminolevulinic Acid/pharmacology , Biosensing Techniques , Photosensitizing Agents/pharmacology , Protoporphyrins/metabolism , Urinary Bladder Neoplasms/metabolism , Cell Line, Tumor , Cystoscopy , Humans , In Vitro Techniques , Microscopy, Fluorescence , Urine/cytology
4.
Colloids Surf B Biointerfaces ; 161: 261-268, 2018 Jan 01.
Article in English | MEDLINE | ID: mdl-29096370

ABSTRACT

Human Mesenchymal Stem cells (hMSCs) are becoming a major focus in biomedical fields. Application of in vitro expanded hMSCs to treat numerous ailments has led to a commercial emphasis on improving hMSC growth ex vivo. Production of substrate independent, novel thin films is one potential tool for production of commercial viable hMSC expansion. Plasma polymerization allow controlled chemical optimisation of large scale surface areas in a substrate independent manner. Previous study shown that plasma polymerized Furfuryl Methacrylate (ppFMA) surfaces allowed primary fibroblast cells adhesion and proliferation. However, under some deposition conditions, particle aggregates formation was observed. These aggregates had the effect of disrupting cell attachment, despite being chemically indistinguishable from the underlying surface. Herein, hMSCs were cultured on ppFMA surfaces to determine their suitability for stem cell culture and observe the effect of particle aggregates on hMSC attachment and growth. Both metabolic and DNA quantification assays showed that surfaces with particle aggregates had lower numbers of attached cells and slower growth. Uniform surfaces without aggregates showed higher cell attachment and growth levels, which were comparable to Thermanox. Phenotypic analysis showed that there was no change to hMSCs phenotype after 7 & 14days of culture on uniform ppFMA surface. Further investigation using time-lapse image analysis indicated that particle aggregates reduced cell attachment by presenting a physically weak boundary layer, which was damaged by intracellular tension during cell spreading. ppFMA surface can provide a stable substrate independent hMSCs expansion interface that could be applied to larger scale bioreactors, beads or scaffolds.


Subject(s)
Cell Proliferation , Furans/chemistry , Mesenchymal Stem Cells/cytology , Methacrylates/chemistry , Polymerization , Cell Adhesion , Cell Culture Techniques/methods , Cells, Cultured , Humans , Mesenchymal Stem Cells/metabolism , Microscopy, Confocal , Microscopy, Electron, Scanning , Particle Size , Photoelectron Spectroscopy , Surface Properties , Time-Lapse Imaging/methods
5.
Biointerphases ; 11(3): 031014, 2016 09 08.
Article in English | MEDLINE | ID: mdl-27609095

ABSTRACT

Furfuryl methacrylate (FMA) is a promising precursor for producing polymers for biomedical and cell therapy applications. Herein, FMA plasma polymer coatings were prepared with different powers, deposition times, and flow rates. The plasma polymer coatings were characterized using atomic force microscopy (AFM), scanning electron microscopy (SEM), x-ray photoelectron spectroscopy (XPS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results from AFM and SEM show the early growth of the coatings and the existence of particle aggregates on the surfaces. XPS results indicated no measureable chemical differences between the deposited films produced under different power and flow rate conditions. ToF-SIMS analysis demonstrated differing amounts of C5H5O (81 m/z) and C10H9O2 (161 m/z) species in the coatings which are related to the furan ring structure. Through judicious choice of plasma polymerization parameters, the quantity of the particle aggregates was reduced, and the fabricated plasma polymer coatings were chemically uniform and smooth. Primary human fibroblasts were cultured on FMA plasma polymer surfaces to determine the effect of surface chemical composition and the presence of particle aggregates on cell culture. Particle aggregates were shown to inhibit fibroblast attachment and proliferation.


Subject(s)
Coated Materials, Biocompatible , Furans/metabolism , Methacrylates/metabolism , Polymers/metabolism , Cell Adhesion , Cell Proliferation , Cells, Cultured , Fibroblasts/physiology , Humans , Microscopy, Atomic Force , Microscopy, Electron, Scanning , Photoelectron Spectroscopy , Spectrometry, Mass, Secondary Ion , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...