Results 1 - 5 de 5
Filter
1.
AJNR Am J Neuroradiol ; 39(4): 727-733, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29496725

ABSTRACT

BACKGROUND AND PURPOSE: The benefit-risk assessment concerning radiation use in pediatric neuroangiography requires an extensive understanding of the doses delivered. This work evaluated the effective dose of 3D rotational angiography in a cohort of pediatric patients with complex neurovascular lesions and directly compared it with conventional 2D-biplane DSA. MATERIALS AND METHODS: Thirty-three 3D rotational angiography acquisitions were acquired in 24 pediatric patients (mean age, 10.4 years). When clinically indicated, following 2D-biplane DSA, 3D rotational angiography was performed with 1 of 3 technical protocols (2 subtracted, 1 unsubtracted). The protocols consisted of 1 factory and 2 customized techniques, with images subsequently reconstructed into CT volumes for clinical management. Raw projections and quantitative dose metrics were evaluated, and the effective dose was calculated. RESULTS: All 3D rotational angiography acquisitions were of diagnostic quality and assisted in patient management. The mean effective doses were 0.5, 0.12, and 0.06 mSv for the factory-subtracted, customized-subtracted, and customized-unsubtracted protocols, respectively. The mean effective dose for 2D-biplane DSA was 0.9 mSv. A direct intraprocedural comparison between 3D and 2D acquisitions indicated that customized 3D rotational angiography protocols delivered mean relative doses of 9% and 15% in unsubtracted and subtracted acquisitions, respectively, compared with biplane DSA, whereas the factory subtracted protocol delivered 68%. CONCLUSIONS: In pediatric neuroangiography, the effective dose for 3D rotational angiography can be significantly lower than for 2D-biplane DSA and can be an essential adjunct in the evaluation of neurovascular lesions. Additionally, available 3D rotational angiography protocols have significant room to be tailored for effectiveness and dose optimization, depending on the clinical question.


Subject(s)
Angiography, Digital Subtraction/methods , Central Nervous System Vascular Malformations/diagnostic imaging , Cerebral Angiography/methods , Imaging, Three-Dimensional/methods , Neuroimaging/methods , Child , Female , Humans , Male , Radiation Dosage , Radiometry
2.
Phys Med Biol ; 53(21): 6097-112, 2008 Nov 07.
Article in English | MEDLINE | ID: mdl-18854611

ABSTRACT

The development and evaluation of a prototype cardiac gating system for double-shot dual-energy (DE) imaging is described. By acquiring both low- and high-kVp images during the resting phase of the cardiac cycle (diastole), heart misalignment between images can be reduced, thereby decreasing the magnitude of cardiac motion artifacts. For this initial implementation, a fingertip pulse oximeter was employed to measure the peripheral pulse waveform ('plethysmogram'), offering potential logistic, cost and workflow advantages compared to an electrocardiogram. A gating method was developed that accommodates temporal delays due to physiological pulse propagation, oximeter waveform processing and the imaging system (software, filter-wheel, anti-scatter Bucky-grid and flat-panel detector). Modeling the diastolic period allowed the calculation of an implemented delay, t(imp), required to trigger correctly during diastole at any patient heart rate (HR). The model suggests a triggering scheme characterized by two HR regimes, separated by a threshold, HR(thresh). For rates at or below HR(thresh), sufficient time exists to expose on the same heartbeat as the plethysmogram pulse [t(imp)(HR) = 0]. Above HR(thresh), a characteristic t(imp)(HR) delays exposure to the subsequent heartbeat, accounting for all fixed and variable system delays. Performance was evaluated in terms of accuracy and precision of diastole-trigger coincidence and quantitative evaluation of artifact severity in gated and ungated DE images. Initial implementation indicated 85% accuracy in diastole-trigger coincidence. Through the identification of an improved HR estimation method (modified temporal smoothing of the oximeter waveform), trigger accuracy of 100% could be achieved with improved precision. To quantify the effect of the gating system on DE image quality, human observer tests were conducted to measure the magnitude of cardiac artifact under conditions of successful and unsuccessful diastolic gating. Six observers independently measured the artifact in 111 patient DE images. The data indicate that successful diastolic gating results in a statistically significant reduction (p < 0.001) in the magnitude of cardiac motion artifact, with residual artifact attributed primarily to gross patient motion.


Subject(s)
Heart/physiology , Oximetry/methods , Artifacts , Heart Rate , Humans , Reproducibility of Results , Sensitivity and Specificity , Time Factors
3.
Med Phys ; 35(2): 629-32, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18383684

ABSTRACT

Experiments were conducted to determine optimal acquisition techniques for bone image decompositions for a prototype dual-energy (DE) imaging system. Technique parameters included kVp pair (denoted [kVp(L)/kVp(H)]) and dose allocation (the proportion of dose in low- and high-energy projections), each optimized to provide maximum signal difference-to-noise ratio in DE images. Experiments involved a chest phantom representing an average patient size and containing simulated ribs and lung nodules. Low- and high-energy kVp were varied from 60-90 and 120-150 kVp, respectively. The optimal kVp pair was determined to be [60/130] kVp, with image quality showing a strong dependence on low-kVp selection. Optimal dose allocation was approximately 0.5-i.e., an equal dose imparted by the low- and high-energy projections. The results complement earlier studies of optimal DE soft-tissue image acquisition, with differences attributed to the specific imaging task. Together, the results help to guide the development and implementation of high-performance DE imaging systems, with applications including lung nodule detection and diagnosis, pneumothorax identification, and musculoskeletal imaging (e.g., discrimination of rib fractures from metastasis).


Subject(s)
Algorithms , Bone and Bones/diagnostic imaging , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Radiography, Thoracic/methods , Subtraction Technique , Humans , Reproducibility of Results , Sensitivity and Specificity
4.
Med Phys ; 34(10): 3904-15, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17985636

ABSTRACT

Experimental and theoretical studies were conducted to determine optimal acquisition techniques for a prototype dual-energy (DE) chest imaging system. Technique factors investigated included the selection of added x-ray filtration, kVp pair, and the allocation of dose between low- and high-energy projections, with total dose equal to or less than that of a conventional chest radiograph. Optima were computed to maximize lung nodule detectability as characterized by the signal-difference-to-noise ratio (SDNR) in DE chest images. Optimal beam filtration was determined by cascaded systems analysis of DE image SDNR for filter selections across the periodic table (Z(filter) = 1-92), demonstrating the importance of differential filtration between low- and high-kVp projections and suggesting optimal high-kVp filters in the range Z(filter) = 25-50. For example, added filtration of approximately 2.1 mm Cu, approximately 1.2 mm Zr, approximately 0.7 mm Mo, and approximately 0.6 mm Ag to the high-kVp beam provided optimal (and nearly equivalent) soft-tissue SDNR. Optimal kVp pair and dose allocation were investigated using a chest phantom presenting simulated lung nodules and ribs for thin, average, and thick body habitus. Low- and high-energy techniques ranged from 60-90 kVp and 120-150 kVp, respectively, with peak soft-tissue SDNR achieved at [60/120] kVp for all patient thicknesses and all levels of imaging dose. A strong dependence on the kVp of the low-energy projection was observed. Optimal allocation of dose between low- and high-energy projections was such that approximately 30% of the total dose was delivered by the low-kVp projection, exhibiting a fairly weak dependence on kVp pair and dose. The results have guided the implementation of a prototype DE imaging system for imaging trials in early-stage lung nodule detection and diagnosis.


Subject(s)
Lung Neoplasms/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/instrumentation , Radiography, Thoracic/methods , Copper/chemistry , Equipment Design , Humans , Lung Neoplasms/diagnosis , Models, Theoretical , Molybdenum/chemistry , Phantoms, Imaging , Radiography/methods , Radiometry , Silver/chemistry , Subtraction Technique , Zirconium/chemistry
5.
Med Phys ; 34(10): 3916-25, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17985637

ABSTRACT

Human observer performance tests were conducted to identify optimal imaging techniques in dual-energy (DE) imaging of the chest with respect to a variety of visualization tasks for soft and bony tissue. Specifically, the effect of kVp selection in low- and high-energy projection pairs was investigated. DE images of an anthropomorphic chest phantom formed the basis for observer studies, decomposed from low-energy and high-energy projections in the range 60-90 kVp and 120-150 kVp, respectively, with total dose for the DE image equivalent to that of a single chest radiograph. Five expert radiologists participated in observer preference tests to evaluate differences in image quality among the DE images. For visualization of soft-tissue structures in the lung, the [60/130] kVp pair provided optimal image quality, whereas [60/140] kVp proved optimal for delineation of the descending aorta in the retrocardiac region. Such soft-tissue detectability tasks exhibited a strong dependence on the low-kVp selection (with 60 kVp providing maximum soft-tissue conspicuity) and a weaker dependence on the high-kVp selection (typically highest at 130-140 kVp). Qualitative examination of DE bone-only images suggests optimal bony visualization at a similar technique, viz., [60/140] kVp. Observer preference was largely consistent with quantitative analysis of contrast, noise, and contrast-to-noise ratio, with subtle differences likely related to the imaging task and spatial-frequency characteristics of the noise. Observer preference tests offered practical, semiquantitative identification of optimal, task-specific imaging techniques and will provide useful guidance toward clinical implementation of high-performance DE imaging systems.


Subject(s)
Lung Neoplasms/diagnostic imaging , Lung Neoplasms/diagnosis , Radiography, Dual-Energy Scanned Projection/instrumentation , Radiography, Dual-Energy Scanned Projection/methods , Radiography, Thoracic/instrumentation , Radiography, Thoracic/methods , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/pathology , Equipment Design , Humans , Image Processing, Computer-Assisted , Observer Variation , Phantoms, Imaging , Radiation Dosage , Reproducibility of Results , Thorax/pathology