Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Opt Express ; 28(24): 35483-35489, 2020 Nov 23.
Article in English | MEDLINE | ID: mdl-33379661

ABSTRACT

We report on electrically driven InP-based photonic-crystal surface-emitting lasers (PCSELs), which possess a deep-air-hole photonic crystal (PC) structure underneath an active region formed by metal-organic vapor-phase-epitaxial (MOVPE) regrowth. Single-mode continuous-wave (CW) lasing operation in 1.3-µm wavelength is successfully achieved at a temperature of 15°C. It is shown that the enhancement of lateral growth during the MOVPE regrowth process of air holes enables the formation of deep air holes with an atomically flat and thin overlayer, whose thickness is less than 100 nm. A threshold current of 120 mA (threshold current density = 0.68 kA/cm2) is obtained in a device with a diameter of 150 µm. A doughnut-like far-field pattern with the narrow beam divergence of less than 1° is observed. Strong optical confinement in the PC structure is revealed from measurements of the photonic band structure, and this strong optical confinement leads to the single-mode CW lasing operation with a low threshold current density.

2.
Opt Express ; 28(13): 19772-19782, 2020 Jun 22.
Article in English | MEDLINE | ID: mdl-32672247

ABSTRACT

We demonstrate low-loss and broadband light transition from III-V functional layers to a Si platform via two-stage adiabatic-crossing coupler waveguides. A 900-µm-long and 2.7-µm-thick III-V film waveguide consisting of a GaInAsP core and InP cladding layers is transferred onto an air-cladding Si photonic chip by the µ-transfer printing (µ-TP) method. An average optical coupling loss per joint of 1.26 dB is obtained in C + L telecommunication bands (1530-1635 nm). The correlation between alignment offset and measured optical coupling loss is discussed with the frequency distribution of µ-TP samples. We also performed a photoluminescence measurement to investigate the material properties in the GaInAsP layer to see if they are distorted by the strong bending stress produced during the pick-up and print steps of the µ-TP process. The peak intensity reduction of 80-90% and a wavelength shift of 0-5 nm (blue shift) were observed after the process. The series of fundamental studies presented here, which combine multiple analyses, contribute to improving our understanding of III-V/Si photonic integration by µ-TP.

3.
Opt Express ; 21(22): 27169-76, 2013 Nov 04.
Article in English | MEDLINE | ID: mdl-24216940

ABSTRACT

We demonstrate sub-millisecond tuning of a prototype parametric tunable dispersion compensator (P-TDC) based on cascaded polarization-diverse four-wave mixing (FWM) process with a fast tunable and highly wavelength-stable pump light source. The pump light source is developed using a tunable distributed amplification chirped sampled grating distributed reflector laser that is fully wavelength tunable by on-chip heaters with a 3-dB frequency response of 45 kHz, resulting in fast dispersion tuning of less than 50 µs without additional timing jitter. The P-TDC is developed as the first prototype to satisfy essential requirements for practical network uses: stable input-polarization diversity, input-wavelength preservation, and seamless dispersion tunability for entire C-band input wavelengths are simultaneously achieved.

4.
Hiroshima J Med Sci ; 60(2): 37-9, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21970186

ABSTRACT

Patients on long-term hemodialysis are at risk of developing malnutrition,and poor nutrient intake is an important factor in this. In the present case, we encountered a 55-year-old Japanese woman with end-stage renal failure and a past history of schizophrenia. Severe systemic edema was observed. Hemodialysis was started, but after one year she suddenly became unable to consume food orally, despite provision of a dietary plan by the nutrition support team (NST). Tube feeding was eventually implemented. Because the systemic edema did not improve, we decided to remove body fluid by intense hemodialysis. Hypotension was often observed during this hemodialysis, requiring dopamine. Over approximately 2 months, the patient's dry weight fell from 73 kg to 62 kg, the patient's activity improved and she became able to eat orally again, allowing tube feeding to be stopped. Although the reason for the sudden anorexia has not been clarified, tube feeding and dry weight control was successful in the treatment of this malnourished hemodialysis patient.


Subject(s)
Edema/therapy , Enteral Nutrition , Kidney Failure, Chronic/therapy , Malnutrition/therapy , Renal Dialysis , Activities of Daily Living , Dopamine/therapeutic use , Edema/etiology , Edema/physiopathology , Female , Humans , Hypotension/drug therapy , Hypotension/etiology , Malnutrition/etiology , Malnutrition/physiopathology , Middle Aged , Nutritional Status , Renal Dialysis/adverse effects , Sympathomimetics/therapeutic use , Treatment Outcome , Weight Loss
SELECTION OF CITATIONS
SEARCH DETAIL
...