Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Ann Surg ; 279(5): 891-899, 2024 May 01.
Article in English | MEDLINE | ID: mdl-37753657

ABSTRACT

OBJECTIVE: To associate surgeon-anesthesiologist team familiarity (TF) with cardiac surgery outcomes. BACKGROUND: TF, a measure of repeated team member collaborations, has been associated with improved operative efficiency; however, examination of its relationship to clinical outcomes has been limited. METHODS: This retrospective cohort study included Medicare beneficiaries undergoing coronary artery bypass grafting (CABG), surgical aortic valve replacement (SAVR), or both (CABG+SAVR) between January 1, 2017, and September 30, 2018. TF was defined as the number of shared procedures between the cardiac surgeon and anesthesiologist within 6 months of each operation. Primary outcomes were 30- and 90-day mortality, composite morbidity, and 30-day mortality or composite morbidity, assessed before and after risk adjustment using multivariable logistic regression. RESULTS: The cohort included 113,020 patients (84,397 CABG; 15,939 SAVR; 12,684 CABG+SAVR). Surgeon-anesthesiologist dyads in the highest [31631 patients, TF median (interquartile range)=8 (6, 11)] and lowest [44,307 patients, TF=0 (0, 1)] TF terciles were termed familiar and unfamiliar, respectively. The rates of observed outcomes were lower among familiar versus unfamiliar teams: 30-day mortality (2.8% vs 3.1%, P =0.001), 90-day mortality (4.2% vs 4.5%, P =0.023), composite morbidity (57.4% vs 60.6%, P <0.001), and 30-day mortality or composite morbidity (57.9% vs 61.1%, P <0.001). Familiar teams had lower overall risk-adjusted odds of 30-day mortality or composite morbidity [adjusted odds ratio (aOR) 0.894 (0.868, 0.922), P <0.001], and for SAVR significantly lower 30-day mortality [aOR 0.724 (0.547, 0.959), P =0.024], 90-day mortality [aOR 0.779 (0.620, 0.978), P =0.031], and 30-day mortality or composite morbidity [aOR 0.856 (0.791, 0.927), P <0.001]. CONCLUSIONS: Given its relationship with improved 30-day cardiac surgical outcomes, increasing TF should be considered among strategies to advance patient outcomes.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aged , United States , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Medicare , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Risk Factors , Treatment Outcome
3.
Front Cardiovasc Med ; 10: 1202174, 2023.
Article in English | MEDLINE | ID: mdl-37840960

ABSTRACT

Objectives: It is uncertain whether concurrent mitral valve repair or replacement for moderate or greater secondary mitral regurgitation at the time of coronary artery bypass graft or aortic valve replacement surgery improves long-term survival. Methods: Patients undergoing coronary artery bypass graft and/or aortic valve replacement surgery with moderate or greater secondary mitral regurgitation were reviewed. The effect of concurrent mitral valve repair or replacement upon long-term mortality was assessed while accounting for patient and operative characteristics and mitral regurgitation severity. Results: Of 1,515 patients, 938 underwent coronary artery bypass graft or aortic valve replacement surgery alone and 577 underwent concurrent mitral valve repair or replacement. Concurrent mitral valve repair or replacement did not alter the risk of postoperative mortality for patients with moderate mitral regurgitation (hazard ratio = 0.93; 0.75-1.17) or more-than-moderate mitral regurgitation (hazard ratio = 1.09; 0.74-1.60) in multivariable regression. Patients with more-than-moderate mitral regurgitation undergoing coronary artery bypass graft-only surgery had a survival advantage from concurrent mitral valve repair or replacement in the first two postoperative years (P = 0.028) that did not persist beyond that time. Patients who underwent concurrent mitral valve repair or replacement had a higher rate of later mitral valve operation or reoperation over the five subsequent years (1.9% vs. 0.2%; P = 0.0014) than those who did not. Conclusions: These observations suggest that mitral valve repair or replacement for more-than-moderate mitral regurgitation at the time of coronary artery bypass grafting may be reasonable in a suitably selected coronary artery bypass graft population but not for aortic valve replacement, with or without coronary artery bypass grafting. Our findings are supportive of 2021 European guidelines that severe secondary mitral regurgitation "should" or be "reasonabl[y]" intervened upon at the time of coronary artery bypass grafting but do not support 2020 American guidelines for performing mitral valve repair or replacement concurrent with aortic valve replacement, with or without coronary artery bypass grafting.

4.
Anesthesiology ; 139(2): 122-141, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37094103

ABSTRACT

BACKGROUND: Conflicting evidence exists regarding the risks and benefits of inotropic therapies during cardiac surgery, and the extent of variation in clinical practice remains understudied. Therefore, the authors sought to quantify patient-, anesthesiologist-, and hospital-related contributions to variation in inotrope use. METHODS: In this observational study, nonemergent adult cardiac surgeries using cardiopulmonary bypass were reviewed across a multicenter cohort of academic and community hospitals from 2014 to 2019. Patients who were moribund, receiving mechanical circulatory support, or receiving preoperative or home inotropes were excluded. The primary outcome was an inotrope infusion (epinephrine, dobutamine, milrinone, dopamine) administered for greater than 60 consecutive min intraoperatively or ongoing upon transport from the operating room. Institution-, clinician-, and patient-level variance components were studied. RESULTS: Among 51,085 cases across 611 attending anesthesiologists and 29 hospitals, 27,033 (52.9%) cases received at least one intraoperative inotrope, including 21,796 (42.7%) epinephrine, 6,360 (12.4%) milrinone, 2,000 (3.9%) dobutamine, and 602 (1.2%) dopamine (non-mutually exclusive). Variation in inotrope use was 22.6% attributable to the institution, 6.8% attributable to the primary attending anesthesiologist, and 70.6% attributable to the patient. The adjusted median odds ratio for the same patient receiving inotropes was 1.73 between 2 randomly selected clinicians and 3.55 between 2 randomly selected institutions. Factors most strongly associated with increased likelihood of inotrope use were institutional medical school affiliation (adjusted odds ratio, 6.2; 95% CI, 1.39 to 27.8), heart failure (adjusted odds ratio, 2.60; 95% CI, 2.46 to 2.76), pulmonary circulation disorder (adjusted odds ratio, 1.72; 95% CI, 1.58 to 1.87), loop diuretic home medication (adjusted odds ratio, 1.55; 95% CI, 1.42 to 1.69), Black race (adjusted odds ratio, 1.49; 95% CI, 1.32 to 1.68), and digoxin home medication (adjusted odds ratio, 1.48; 95% CI, 1.18 to 1.86). CONCLUSIONS: Variation in inotrope use during cardiac surgery is attributable to the institution and to the clinician, in addition to the patient. Variation across institutions and clinicians suggests a need for future quantitative and qualitative research to understand variation in inotrope use affecting outcomes and develop evidence-based, patient-centered inotrope therapies.


Subject(s)
Cardiac Surgical Procedures , Cardiotonic Agents , Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Myocardial Contraction/drug effects , Cardiotonic Agents/therapeutic use , Epinephrine/therapeutic use , Dopamine/therapeutic use , Dobutamine/therapeutic use , Milrinone/therapeutic use , Intraoperative Care
5.
J Cardiothorac Vasc Anesth ; 37(4): 570-581, 2023 04.
Article in English | MEDLINE | ID: mdl-36517335

ABSTRACT

The complexity of structural heart interventions has led to a demand for sophisticated periprocedural imaging guidance. Although traditional 2-dimensional (2D) transesophageal techniques are used widely, new-generation 3D ultrasound probes enable high temporal and spatial resolution. Multiplanar reconstruction of acquired 3D datasets has gained considerable momentum for precise imaging and to increase the validity of measurements. Previously, this technique was used after the acquisition of suitable 3D datasets. Recent advances in technology have enabled the use of live mode for multiplanar reconstruction across different ultrasound vendor platforms. The use of live multiplanar reconstruction can enhance the precision in real-time imaging, enable simultaneous visualization of structures of interest in multiple planes, reduce the need for probe manipulation, and thereby contribute to the success of the procedures. In this narrative review, the authors describe the rationale and utility for 3D transesophageal live multiplanar reconstruction, and outline its use for the structural heart interventions of mitral and tricuspid valve edge-to-edge repair, left atrial appendage occlusion, and the Lampoon procedure. A 3D transesophageal echocardiogram with live-multiplanar reconstruction has the potential to advance guidance of these complex interventions.


Subject(s)
Cardiac Surgical Procedures , Echocardiography, Three-Dimensional , Humans , Echocardiography, Transesophageal/methods , Tricuspid Valve , Echocardiography, Three-Dimensional/methods
6.
Circ Cardiovasc Interv ; 15(9): e011756, 2022 09.
Article in English | MEDLINE | ID: mdl-36126131

ABSTRACT

BACKGROUND: In some patients, the alternative access route for transcatheter aortic valve replacement (TAVR) is utilized because the conventional transfemoral approach is not felt to be either feasible or optimal. However, accurate prognostication of patient risks is not well established. This study examines the associations between peripheral (transsubclavian/transaxillary, and transcarotid) versus central access (transapical and transaortic) in alternative access TAVR and 30-day and 1-year end points of mortality and stroke for all valve platforms. METHODS: Using data from The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry with linkage to Medicare claims, patients who underwent alternative access TAVR from June 1, 2015 to June 30, 2018 were identified. Adjusted and unadjusted Cox proportional hazards modeling were performed to determine the association between alternate access TAVR site and 30-day and 1-year end points of mortality and stroke. RESULTS: Of 7187 alternative access TAVR patients, 3725 (52%) had peripheral access and 3462 (48%) had central access. All-cause mortality was significantly lower in peripheral access versus central access group at in-hospital and 1 year (2.9% versus 6.3% and 20.3% versus 26.6%, respectively), but stroke rates were higher (5.0% versus 2.8% and 7.3% versus 5.5%, respectively; all P<0.001). These results persisted after 1-year adjustment (death adjusted hazard ratio, 0.72 [95% CI, 0.62-0.85] and stroke adjusted hazard ratio, 2.92 [95% CI, 2.21-3.85]). When broken down by individual subtypes, compared with transaxillary/subclavian access patients, transapical, and transaortic access patients had higher all-cause mortality but less stroke (P<0.05). CONCLUSIONS: In this real-world, contemporary, nationally representative benchmarking study of alternate access TAVR sites, peripheral access was associated with favorable mortality and morbidity outcomes compared with central access, at the expense of higher stroke. These findings may allow for accurate prognostication of risk for patient counseling and decision-making for the heart team with regard to alternative access TAVR.


Subject(s)
Aortic Valve Stenosis , Cardiology , Stroke , Surgeons , Transcatheter Aortic Valve Replacement , Aged , Humans , Medicare , Registries , Stroke/etiology , Treatment Outcome , United States
7.
Semin Thorac Cardiovasc Surg ; 34(2): 585-594, 2022.
Article in English | MEDLINE | ID: mdl-34089824

ABSTRACT

Enhanced Recovery After Surgery (ERAS) pathways have improved clinical outcomes, cost-effectiveness, and patient satisfaction across multiple non-cardiac surgical specialties. Since the adaptation of ERAS in cardiac surgery is rapidly increasing yet still evolving, herein, we demonstrate early results of our implementation of ERAS cardiac guidelines. We retrospectively reviewed all patients who were managed with our institutional ERAS Cardiac Surgery guidelines between 5/2018 and 6/2019(N = 102). Postoperative primary outcomes (total ventilation times(hours), intensive-care unit(ICU) stay, and postoperative hospital length of stay (LOS)) were compared to 1:1 propensity matched controls from the pre ERAS era between January 2017 and March 2019. A total of 76 propensity-matched pairs were identified. Compared to the matched controls, ERAS patients had significantly shorter median ventilation times(3.5 vs. 5.3 hours, p = .01), ICU stays(median 28 vs 48 hours, p=.005) and postoperative hospital LOS (median 5 vs. 6 days, p = .03). There were no operative mortalities and no significant differences in 30-day readmission rates. There were also no significant differences in post-operative stroke, acute kidney injury, atrial fibrillation, and reoperation rates for bleeding. Two-year survival was also not statistically different between the two cohorts (p = .22). Our initial experience with implementation of ERAS protocols in cardiac surgery appear to demonstrate that these protocols are associated with shorter ventilation times, ICU stay, and hospital LOS without compromising patient outcomes. While these results are promising yet preliminary, further studies are warranted to demonstrate whether ERAS algorithms in cardiac surgery can consistently expedite postoperative recovery and improve outcomes.


Subject(s)
Cardiac Surgical Procedures , Enhanced Recovery After Surgery , Cardiac Surgical Procedures/adverse effects , Humans , Length of Stay , Postoperative Complications/etiology , Retrospective Studies , Treatment Outcome
8.
Interact Cardiovasc Thorac Surg ; 32(1): 9-19, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33313764

ABSTRACT

OBJECTIVES: Functional mitral regurgitation (MR) is observed with ischaemic heart disease or aortic valve disease. Assessing the value of mitral valve repair or replacement (MVR/P) is complicated by frequent discordance between preoperative transthoracic echocardiographic (pTTE) and intraoperative transoesophageal echocardiographic (iTOE) assessment of MR severity. We examined the association of pTTE and iTOE with postoperative mortality in patients with or without MR, at the time of coronary artery bypass grafting (CABG) and/or aortic valve replacement without MVR/P. METHODS: Medical records of 6629 patients undergoing CABG and/or aortic valve replacement surgery with or without functional MR and who did not undergo MVR/P were reviewed. MR severity assessed by pTTE and iTOE were examined for association with postoperative mortality using proportional hazards regression while accounting for patient and operative characteristics. RESULTS: In 72% of 709 patients with clinically significant (moderate or greater) functional MR detected by pTTE, iTOE performed after induction of anaesthesia demonstrated a reduction in MR severity, while 2% of patients had increased severity of MR by iTOE. iTOE assessment of MR was better associated with long-term postoperative mortality than pTTE in patients with moderate MR [hazard ratio (HR) 1.31 (1.11-1.55) vs 1.02 (0.89-1.17), P-value for comparison of HR 0.025] but was not different for more than moderate MR [1.43 (0.96-2.14) vs 1.27 (0.80-2.02)]. CONCLUSIONS: In patients undergoing CABG and/or aortic valve replacement without MVR/P, these findings support intraoperative reassessment of MR severity by iTOE as an adjunct to pTTE in the prediction of mortality. Alone, these findings do not yet provide evidence for an operative strategy.


Subject(s)
Coronary Artery Bypass , Echocardiography, Transesophageal , Echocardiography , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency/diagnostic imaging , Aged , Heart Valve Prosthesis , Humans , Male , Middle Aged , Mitral Valve Insufficiency/surgery , Myocardial Ischemia/surgery , Proportional Hazards Models , Retrospective Studies , Treatment Outcome
9.
J Educ Perioper Med ; 22(2): E642, 2020.
Article in English | MEDLINE | ID: mdl-32964070

ABSTRACT

BACKGROUND: Focused cardiac ultrasound (FoCUS) is an increasingly used diagnostic modality for anesthesiologists and intensivists. However, training residents in its use can be resource intensive. We investigated the feasibility of implementing a self-guided FoCUS curriculum for anesthesiology residents rotating in the postanesthesia care unit (PACU). METHODS: We created a FoCUS curriculum with the aim of providing a consistent largely self-guided experience that would improve FoCUS knowledge and skills while minimizing ongoing time commitment from faculty. To achieve this, we used several methods: (1) developed video didactics and quizzes; (2) used an online educational delivery platform to automate delivery of educational content, monitor resident progress, and elicit feedback; (3) used the transthoracic echocardiography simulator for aided hands-on learning; (4) dedicated educational time that integrated into PACU workflow; (5) worked with a cardiac sonographer; and (6) used image storage software to facilitate remote feedback by ultrasound faculty. The response to the curriculum was evaluated using Kirkpatrick levels 1-3. RESULTS: Forty-one anesthesiology residents rotated through the PACU over a 1-year period and completed this weeklong self-guided FoCUS curriculum. Interesting findings include: (1) favorable evaluation from the residents and (2) improvement in image acquisition skills by objective measures. Once the curriculum was established, ongoing faculty time commitment was approximately 1 hour 20 minutes per week. CONCLUSIONS: The implementation of a FoCUS curriculum in the PACU resulted in favorable resident evaluation and improved FoCUS skills. The curriculum was feasible and self-sustainable because of the novel educational approach employed.

10.
JACC Cardiovasc Interv ; 13(3): 335-343, 2020 02 10.
Article in English | MEDLINE | ID: mdl-32029250

ABSTRACT

OBJECTIVES: The aim of this study was to examine whether hospital surgical aortic valve replacement (SAVR) volume was associated with corresponding transcatheter aortic valve replacement (TAVR) outcomes. BACKGROUND: Recent studies have demonstrated a volume-outcome relationship for TAVR. METHODS: In total, 208,400 fee-for-service Medicare beneficiaries were analyzed for all aortic valve replacement procedures from 2012 to 2015. Claims for patients <65 years of age, concomitant coronary artery bypass grafting surgery, other heart valve procedures, or other major open heart procedures were excluded, as were secondary admissions for aortic valve replacement. Hospital SAVR volumes were stratified on the basis of mean annual SAVR procedures during the study period. The primary outcomes were 30-day and 1-year post-operative TAVR survival. Adjusted survival following TAVR was assessed using multivariate Cox regression. RESULTS: A total of 65,757 SAVR and 42,967 TAVR admissions were evaluated. Among TAVR procedures, 21.7% (n = 9,324) were performed at hospitals with <100 (group 1), 35.6% (n = 15,298) at centers with 100 to 199 (group 2), 22.9% (n = 9,828) at centers with 200 to 299 (group 3), and 19.8% (n = 8,517) at hospitals with ≥300 SAVR cases/year (group 4). Compared with group 4, 30-day TAVR mortality risk-adjusted odds ratios were 1.32 (95% confidence interval: 1.18 to 1.47) for group 1, 1.25 (95% confidence interval: 1.12 to 1.39) for group 2, and 1.08 (95% confidence interval: 0.82 to 1.25) for group 3. These adjusted survival differences in TAVR outcomes persisted at 1 year post-procedure. CONCLUSIONS: Total hospital SAVR volume appears to be correlated with TAVR outcomes, with higher 30-day and 1-year mortality observed at low-volume centers. These data support the importance of a viable surgical program within the heart team, and the use of minimum SAVR hospital thresholds may be considered as an additional metric for TAVR performance.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation/trends , Hospitals, High-Volume/trends , Hospitals, Low-Volume/trends , Outcome and Process Assessment, Health Care/trends , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Clinical Competence , Databases, Factual , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Medicare , Quality Indicators, Health Care/trends , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
11.
Anesth Analg ; 130(2): 300-306, 2020 02.
Article in English | MEDLINE | ID: mdl-31453871

ABSTRACT

BACKGROUND: Currently available 2-dimensional (2D) echocardiographic methods for accurately assessing the mitral valve orifice area (MVA) after mitral valve repair (MVr) are limited due to its complex 3-dimensional (3D) geometry. We compared repaired MVAs obtained with commonly used 2D and 3D echocardiographic methods to a 3D orifice area (3DOA), which is a novel echocardiographic measurement and independent of geometric assumptions. METHODS: Intraoperative 2D and 3D transesophageal echocardiography (TEE) images from 20 adult cardiac surgery patients who underwent MVr for mitral regurgitation obtained immediately after repair were retrospectively reviewed. MVAs obtained by pressure half-time (PHT), 2D planimetry (2DP), and 3D planimetry (3DP) were compared to those derived by 3DOA. RESULTS: MVAs (mean value ± standard deviation [SD]) after MVr were obtained by PHT (3 ± 0.6 cm), 2DP (3.58 ± 0.75 cm), 3D planimetry (3DP; 2.78 ± 0.74 cm), and 3DOA (2.32 ± 0.76 cm). MVAs obtained by the 3DOA method were significantly smaller compared to those obtained by PHT (mean difference, 0.68 cm; P = .0003), 2DP (mean difference, 1.26 cm; P < .0001), and 3DP (mean difference, 0.46 cm; P = .003). In addition, MVA defined as an area ≤1.5 cm was identified by 3DOA in 2 patients and by 3DP in 1 patient. CONCLUSIONS: Post-MVr MVAs obtained using the novel 3DOA method were significantly smaller than those obtained by conventional echocardiographic methods and may be consistent with a higher incidence of MVA reduction when compared to 2D techniques. Further studies are still needed to establish the clinical significance of 3D echocardiographic techniques used to measure MVA after MVr.


Subject(s)
Echocardiography, Three-Dimensional/methods , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Echocardiography/methods , Echocardiography/standards , Echocardiography, Three-Dimensional/standards , Female , Humans , Male , Middle Aged , Retrospective Studies
12.
Am J Cardiol ; 123(12): 1983-1991, 2019 06 15.
Article in English | MEDLINE | ID: mdl-30952379

ABSTRACT

Sex-based differences in outcomes have been shown to affect caregiving in medical disciplines. Increased spending due to postacute care transfer policies has led hospitals to further scrutinize patient outcomes and disposition patterns after inpatient admissions. We examined sex-based differences in rehabilitative service utilization after transcatheter aortic valve implantation (TAVI). We queried all TAVI discharges in the National Inpatient Sample database from 2012 to 2014 (n = 40,900). Thirteen thousand eight hundred fifteen patients were discharged to home and 12,175 patients were discharged to rehabilitation facility; those not discharged routinely or to a rehabilitation facility were excluded. Patients with nonhome discharges were older (83.3 vs 79.0 years) and female (58.3% vs 37.7%) with a greater number of chronic conditions (9.91 vs 9.03) and number of Elixhauser co-morbidities (6.5 vs 5.8, all p < 0.05). Nonhome discharge patients also had a significantly longer length of stay (LOS) (11.3 days vs 5.3 days) and higher hospitalization costs ($66,246 vs $48,710, all p < 0.001) compared to home-discharged patients. Overall in-hospital mortality for female patients who underwent TAVI was higher compared to males (4.6% vs 3.6%, p < 0.05). On multivariable logistic regression, female sex was an independent predictor for disposition to rehabilitation facilities after TAVI (odds ratio 2.17; 95% confidence interval: 1.88 to 2.50; p < 0.001). Other independent predictors for females discharged to rehabilitation included the presence of rheumatoid arthritis and collagen vascular disease, body mass index greater than 30 kg/m2, depression, and sum of Elixhauser co-morbidities (all p < 0.001). In conclusion, nonhome discharge TAVI patients added LOS and hospital costs compared to home discharge TAVI patients, and female sex was one of the major predictors despite the lower co-morbidities.


Subject(s)
Aortic Valve Stenosis/rehabilitation , Aortic Valve Stenosis/surgery , Home Care Services , Hospitalization , Patient Discharge , Rehabilitation Centers , Transcatheter Aortic Valve Replacement/rehabilitation , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Female , Hospital Mortality , Humans , Length of Stay , Male , Middle Aged , Sex Factors , Treatment Outcome , United States
13.
Semin Cardiothorac Vasc Anesth ; 23(1): 48-56, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30404582

ABSTRACT

The advent of percutaneous therapies has significantly altered therapeutic options for patients with valvular heart disease. Building on the success of transcatheter aortic valve replacement, both expanded indications and purpose-built devices are now being used to address percutaneous approaches for mitral valve pathology. While surgical mitral valve repair remains the gold standard for addressing significant mitral valve pathology, there has been a progressive increase in the utilization of bioprosthetic valves despite their limited lifespan. The risks of reoperation to address mitral valve repair failure or bioprosthetic valve dysfunction is not insignificant. In light of the aging population and the potential for significant associated comorbidities, less invasive alternative techniques hold particular appeal. Utilization of commercially available transcatheter aortic valve replacement valves for failed surgical valves has been shown to have better short-term mortality than would be predicted for open reoperation. As a result, the US Food and Drug Administration approved the utilization of transcatheter mitral valve-in-valve replacement for the failed bioprosthetic valve in high surgical risk patients. Despite the favorable outcomes, transcatheter mitral valve-in-valve is not without procedural challenges and potential complications including malpositioning, embolization, paravalvular leak, and outflow tract obstruction. Awareness of these challenges, mitigation strategies, and therapeutic options is imperative to optimizing outcomes in this high-risk patient population.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Stenosis/surgery , Mitral Valve/pathology , Mitral Valve/surgery , Humans , Reoperation , Treatment Failure
14.
J Heart Valve Dis ; 27(1): 9-16, 2018 Jan.
Article in English | MEDLINE | ID: mdl-30560594

ABSTRACT

BACKGROUND: A lower rate of permanent pacemaker (PPM) has been linked to a target aortic implantation height (AIH) >0.70, following transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve. Based on clinical experience, it was hypothesized that a higher AIH (≥0.85) would lower the rate of PPM implantation. METHODS: A total of 127 patients (66 females, 61 males; mean age 82 ± 8 years) underwent TAVR with the SAPIEN 3 valve between May 2015 and July 2016. AIH was defined as the proportion of the valve frame above the aortic annulus in the post-deployment aortogram. A target AIH (≥0.70) was achieved in 113 patients (89%). Cases were stratified into a High Implantation (HI) group (AIH ≥0.85; 33 patients) or a Standard Implantation (SI) group (AIH <0.85; 94 patients). RESULTS: The mean Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score of all patients was 6.4 ± 3.5%. Preoperative right bundle branch block (RBBB) was prevalent in 13% of SI patients, and in 18% of HI patients (p = 0.56). There were no significant differences in operative mortality (3.2% versus 0%), median length of stay (2 days versus 3 days) and incidence of moderate-to-severe paravalvular leak (3.2% versus 0%; all p >0.410) between SI and HI patients, respectively. Likewise, the incidence of new PPM did not differ between the two groups (12% in HI versus 13% in SI; p ≥0.99). The mean AIH was similar for patients with PPM implantation (0.80 ± 0.08) compared to those without (0.78 ± 0.06; p = 0.520). Preoperative RBBB was significantly associated with PPM implantation (odds ratio (OR) 10.1; p = 0.002), and patients who underwent PPM implantation had a higher operative mortality (12.5% versus 1%; p = 0.040). CONCLUSIONS: Among TAVR patients who received the SAPIEN 3 heart valve, a higher AIH (≥0.85) was not associated with a lower rate of PPM implantation or increased operative mortality. Prior RBBB was the only independent risk factor for new PPM implantation. Long-term follow up is crucial in determining the clinical significance of PPM implantation.


Subject(s)
Aortic Valve/surgery , Bundle-Branch Block/therapy , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortography , Bundle-Branch Block/complications , Cardiac Pacing, Artificial , Female , Humans , Male
15.
Perioper Med (Lond) ; 7: 24, 2018.
Article in English | MEDLINE | ID: mdl-30386591

ABSTRACT

BACKGROUND: The utility of pulmonary artery catheters (PACs) and their measurements depend on a variety of factors including data interpretation and personnel training. This US multi-center, retrospective electronic health record (EHR) database analysis was performed to identify associations between PAC use in adult cardiac surgeries and effects on subsequent clinical outcomes. METHODS: This cohort analysis utilized the Cerner Health Facts database to examine patients undergoing isolated coronary artery bypass graft (CABG), isolated valve surgery, aortic surgery, other complex non-valvular and multi-cardiac procedures, and/or heart transplant from January 1, 2011, to June 30, 2015. A total of 6844 adults in two cohorts, each with 3422 patients who underwent a qualifying cardiac procedure with or without the use of a PAC for monitoring purposes, were included. Patients were matched 1:1 using a propensity score based upon the date and type of surgery, hospital demographics, modified European System for Cardiac Operative Risk Evaluation (EuroSCORE II), and patient characteristics. Primary outcomes of 30-day in-hospital mortality, length of stay, cardiopulmonary morbidity, and infectious morbidity were analyzed after risk adjustment for acute physiology score. RESULTS: There was no difference in the 30-day in-hospital mortality rate between treatment groups (OR, 1.17; 95% CI, 0.65-2.10; p = 0.516). PAC use was associated with a decreased length of stay (9.39 days without a PAC vs. 8.56 days with PAC; p < 0.001), a decreased cardiopulmonary morbidity (OR, 0.87; 95% CI, 0.79-0.96; p < 0.001), and an increased infectious morbidity (OR, 1.28; 95% CI, 1.10-1.49; p < 0.001). CONCLUSIONS: Use of a PAC during adult cardiac surgery is associated with decreased length of stay, reduced cardiopulmonary morbidity, and increased infectious morbidity but no increase in the 30-day in-hospital mortality. This suggests an overall potential benefit associated with PAC-based monitoring in this population. TRIAL REGISTRATION: The study was registered at clinicaltrials.gov (NCT02964026) on November 15, 2016.

18.
Anesthesiology ; 128(4): 821-831, 2018 04.
Article in English | MEDLINE | ID: mdl-29369062

ABSTRACT

BACKGROUND: Obtaining reliable and valid information on resident performance is critical to patient safety and training program improvement. The goals were to characterize important anesthesia resident performance gaps that are not typically evaluated, and to further validate scores from a multiscenario simulation-based assessment. METHODS: Seven high-fidelity scenarios reflecting core anesthesiology skills were administered to 51 first-year residents (CA-1s) and 16 third-year residents (CA-3s) from three residency programs. Twenty trained attending anesthesiologists rated resident performances using a seven-point behaviorally anchored rating scale for five domains: (1) formulate a clear plan, (2) modify the plan under changing conditions, (3) communicate effectively, (4) identify performance improvement opportunities, and (5) recognize limits. A second rater assessed 10% of encounters. Scores and variances for each domain, each scenario, and the total were compared. Low domain ratings (1, 2) were examined in detail. RESULTS: Interrater agreement was 0.76; reliability of the seven-scenario assessment was r = 0.70. CA-3s had a significantly higher average total score (4.9 ± 1.1 vs. 4.6 ± 1.1, P = 0.01, effect size = 0.33). CA-3s significantly outscored CA-1s for five of seven scenarios and domains 1, 2, and 3. CA-1s had a significantly higher proportion of worrisome ratings than CA-3s (chi-square = 24.1, P < 0.01, effect size = 1.50). Ninety-eight percent of residents rated the simulations more educational than an average day in the operating room. CONCLUSIONS: Sensitivity of the assessment to CA-1 versus CA-3 performance differences for most scenarios and domains supports validity. No differences, by experience level, were detected for two domains associated with reflective practice. Smaller score variances for CA-3s likely reflect a training effect; however, worrisome performance scores for both CA-1s and CA-3s suggest room for improvement.


Subject(s)
Anesthesiology/education , Anesthesiology/standards , Clinical Competence/standards , Internship and Residency/standards , Manikins , Anesthesiology/methods , Cross-Sectional Studies , Female , Humans , Internship and Residency/methods , Male , Prospective Studies , Reproducibility of Results
19.
Interact Cardiovasc Thorac Surg ; 26(6): 938-943, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29365108

ABSTRACT

OBJECTIVES: Although the transfemoral approach for transcatheter aortic valve replacement is the preferred choice, alternative access remains indicated for inadequate iliofemoral vessels. We report the successful implementation of a novel fast-track (FT) protocol for patients undergoing alternative access transcatheter aortic valve replacement compared with conventional controls. METHODS: Between September 2014 and January 2017, 31 and 23 patients underwent alternative access transcatheter aortic valve replacement under FT and pre-fast-track (p-FT) protocols, respectively. Comparisons of outcomes (in terms of mortality, complications, readmissions and resource utilization) were made before and after the implantation of the FT protocol in September 2015. RESULTS: Overall, mean age was 78.7 years in FT and 79.6 years in p-FT patients (P = 0.71). There were no significant differences in procedural (3.2% vs 13.0%, P = 0.301) or 90-day mortality (3.2% vs 17.4%, P = 0.151) between the FT and p-FT groups, respectively. Compared with p-FT patients, FT patients had significantly shorter intensive care unit stays (12 h vs 27 h, P = 0.006) and a trend towards more discharges within 3 days (41.9% vs 17.4%, P = 0.081). Resource utilization analyses projected a 56% and 17% reduction in the mean intensive care unit time (hours) per 100 patients and the total length of stay (days) per 100 patients, respectively, with respect to the FT approach. CONCLUSIONS: This pilot study demonstrates the feasibility and safety of the novel FT protocol for alternative access transcatheter aortic valve replacement, resulting in shorter intensive care unit stays, without increasing procedural complications or readmissions. With the expected increase in transcatheter aortic valve replacement utilization, FT protocols should be integrated with a multidisciplinary heart team approach to enhance patient recovery and optimize resource utilization.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Clinical Protocols , Female , Fluoroscopy , Humans , Intensive Care Units , Length of Stay , Male , Pilot Projects , Recovery of Function , Treatment Outcome
20.
Anesth Analg ; 125(1): 29-37, 2017 07.
Article in English | MEDLINE | ID: mdl-28537973

ABSTRACT

BACKGROUND: The cardiac operating room is a complex environment requiring efficient and effective communication between multiple disciplines. The objectives of this study were to identify and rank critical time points during the perioperative care of cardiac surgical patients, and to assess variability in responses, as a correlate of a shared mental model, regarding the importance of these time points between and within disciplines. METHODS: Using Delphi technique methodology, panelists from 3 institutions were tasked with developing a list of critical time points, which were subsequently assigned to pause point (PP) categories. Panelists then rated these PPs on a 100-point visual analog scale. Descriptive statistics were expressed as percentages, medians, and interquartile ranges (IQRs). We defined low response variability between panelists as an IQR ≤ 20, moderate response variability as an IQR > 20 and ≤ 40, and high response variability as an IQR > 40. RESULTS: Panelists identified a total of 12 PPs. The PPs identified by the highest number of panelists were (1) before surgical incision, (2) before aortic cannulation, (3) before cardiopulmonary bypass (CPB) initiation, (4) before CPB separation, and (5) at time of transfer of care from operating room (OR) to intensive care unit (ICU) staff. There was low variability among panelists' ratings of the PP "before surgical incision," moderate response variability for the PPs "before separation from CPB," "before transfer from OR table to bed," and "at time of transfer of care from OR to ICU staff," and high response variability for the remaining 8 PPs. In addition, the perceived importance of each of these PPs varies between disciplines and between institutions. CONCLUSIONS: Cardiac surgical providers recognize distinct critical time points during cardiac surgery. However, there is a high degree of variability within and between disciplines as to the importance of these times, suggesting an absence of a shared mental model among disciplines caring for cardiac surgical patients during the perioperative period. A lack of a shared mental model could be one of the factors contributing to preventable errors in cardiac operating rooms.


Subject(s)
Cardiac Surgical Procedures/methods , Cardiology , Cardiopulmonary Bypass/methods , Models, Psychological , Patient Care Team , Algorithms , Cardiology/organization & administration , Communication , Delphi Technique , Heart Diseases/surgery , Humans , Intensive Care Units , Interdisciplinary Communication , Models, Statistical , Operating Rooms , Perioperative Care , Perioperative Period , Surveys and Questionnaires , Visual Analog Scale , Workforce
SELECTION OF CITATIONS
SEARCH DETAIL
...