Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Total Environ ; 813: 152556, 2022 Mar 20.
Article in English | MEDLINE | ID: mdl-34952082

ABSTRACT

Waterborne diseases cause millions of deaths worldwide, especially in developing communities. The monitoring and rapid detection of microbial pathogens in water is critical for public health protection. This study reports the development of a proof-of-concept portable pathogen analysis system (PPAS) that can detect bacteria in water with the potential application in a point-of-sample collection setting. A centrifugal microfluidic platform is adopted to integrate bacterial cell lysis in water samples, nucleic acid extraction, and reagent mixing with a droplet digital loop mediated isothermal amplification assay for bacteria quantification onto a single centrifugal disc (CD). Coupled with a portable "CD Driver" capable of automating the assay steps, the CD functions as a single step bacterial detection "lab" without the need to transfer samples from vial-to-vial as in a traditional laboratory. The prototype system can detect Enterococcus faecalis, a common fecal indicator bacterium, in water samples with a single touch of a start button within 1 h and having total hands-on-time being less than 5 min. An add-on bacterial concentration cup prefilled with absorbent polymer beads was designed to integrate with the pathogen CD to improve the downstream quantification sensitivity. All reagents and amplified products are contained within the single-use disc, reducing the opportunity of cross contamination of other samples by the amplification products. This proof-of-concept PPAS lays the foundation for field testing devices in areas needing more accessible water quality monitoring tools and are at higher risk for being exposed to contaminated waters.


Subject(s)
Microfluidic Analytical Techniques , Microfluidics , Nucleic Acid Amplification Techniques , Water Quality
2.
Lab Chip ; 21(3): 534-545, 2021 02 07.
Article in English | MEDLINE | ID: mdl-33393956

ABSTRACT

Rapid, point-of-care (PoC) diagnostics for antibiotic susceptibility testing (AST) are critical in combating the antimicrobial resistance epidemic. While new, alternative technologies are capable of rapidly identifying antibiotic resistance, traditional AST methods, where a patient sample is incubated with different antibiotics, remain the most reliable and practical in determining antibiotic effectiveness. Here, we demonstrate a novel sample incubation technique on a microfluidic centrifugal disc (CD) as a proof of concept automated sample processing platform for AST. By using ribosomal RNA (rRNA) as a marker for cell growth, we demonstrated that incubation on the microfluidic CD was enhanced (>1.6 fold) for 11 out of 14 clinically relevant isolates of Escherichia coli compared to traditional shaker incubators. Finally, we utilize the system to identify antibiotic resistance of 11 E. coli isolates incubated with 5 different antibiotics in under 2 hours.


Subject(s)
Escherichia coli , Microfluidics , Anti-Bacterial Agents/pharmacology , Drug Resistance, Microbial , Escherichia coli/genetics , Humans , Microbial Sensitivity Tests , Specimen Handling
3.
Proc Natl Acad Sci U S A ; 110(45): 18190-5, 2013 Nov 05.
Article in English | MEDLINE | ID: mdl-24151335

ABSTRACT

Evolutionary theory has long argued that the entrenched rules of development constrain the range of variations in a given form, but few empirical examples are known. Here we provide evidence for a very deeply conserved skeletal module constraining the morphology of the phalanges within a digit. We measured the sizes of phalanges within populations of two bird species and found that successive phalanges within a digit exhibit predictable relative proportions, whether those phalanges are nearly equal in size or exhibit a more striking gradient in size from large to small. Experimental perturbations during early stages of digit formation demonstrate that the sizes of the phalanges within a digit are regulated as a system rather than individually. However, the sizes of the phalanges are independent of the metatarsals. Temporal studies indicate that the relative sizes of the phalanges are established at the time of initial cell condensation. Measurements of phalanges across species from six major taxonomic lineages showed that the same predictable range of variants is conserved across vast taxonomic diversity and evolutionary time, starting with the very origins of tetrapods. Although in general phalangeal variations fall within a range of nearly equal-sized phalanges to those following a steep large-to-small gradient, a novel derived condition of excessive elongation of the distal-most phalanges has evolved convergently in multiple lineages, for example under selection for grasping rather than walking or swimming. Even in the context of this exception, phalangeal variations observed in nature are a small subset of potential morphospace.


Subject(s)
Biological Evolution , Bones of Upper Extremity/growth & development , Models, Biological , Osteogenesis/physiology , Toe Phalanges/growth & development , Vertebrates/growth & development , Animals , Bones of Upper Extremity/diagnostic imaging , Organ Size , Radiography , Selection, Genetic , Species Specificity , Toe Phalanges/diagnostic imaging
4.
Ecol Evol ; 3(6): 1471-83, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23789060

ABSTRACT

When organisms perform a single task, selection leads to phenotypes that maximize performance at that task. When organisms need to perform multiple tasks, a trade-off arises because no phenotype can optimize all tasks. Recent work addressed this question, and assumed that the performance at each task decays with distance in trait space from the best phenotype at that task. Under this assumption, the best-fitness solutions (termed the Pareto front) lie on simple low-dimensional shapes in trait space: line segments, triangles and other polygons. The vertices of these polygons are specialists at a single task. Here, we generalize this finding, by considering performance functions of general form, not necessarily functions that decay monotonically with distance from their peak. We find that, except for performance functions with highly eccentric contours, simple shapes in phenotype space are still found, but with mildly curving edges instead of straight ones. In a wide range of systems, complex data on multiple quantitative traits, which might be expected to fill a high-dimensional phenotype space, is predicted instead to collapse onto low-dimensional shapes; phenotypes near the vertices of these shapes are predicted to be specialists, and can thus suggest which tasks may be at play.

5.
PLoS One ; 8(3): e57455, 2013.
Article in English | MEDLINE | ID: mdl-23469195

ABSTRACT

Sensory systems often detect multiple types of inputs. For example, a receptor in a cell-signaling system often binds multiple kinds of ligands, and sensory neurons can respond to different types of stimuli. How do sensory systems compare these different kinds of signals? Here, we consider this question in a class of sensory systems - including bacterial chemotaxis- which have a property known as fold-change detection: their output dynamics, including amplitude and response time, depends only on the relative changes in signal, rather than absolute changes, over a range of several decades of signal. We analyze how fold-change detection systems respond to multiple signals, using mathematical models. Suppose that a step of fold F1 is made in input 1, together with a step of F2 in input 2. What total response does the system provide? We show that when both input signals impact the same receptor with equal number of binding sites, the integrated response is multiplicative: the response dynamics depend only on the product of the two fold changes, F1F2. When the inputs bind the same receptor with different number of sites n1 and n2, the dynamics depend on a product of power laws, [Formula: see text]. Thus, two input signals which vary over time in an inverse way can lead to no response. When the two inputs affect two different receptors, other types of integration may be found and generally the system is not constrained to respond according to the product of the fold-change of each signal. These predictions can be readily tested experimentally, by providing cells with two simultaneously varying input signals. The present study suggests how cells can compare apples and oranges, namely by comparing each to its own background level, and then multiplying these two fold-changes.


Subject(s)
Models, Biological , Receptors, Cell Surface/physiology , Sensory Receptor Cells/physiology , Animals , Biological Factors/pharmacology , Caenorhabditis elegans/drug effects , Caenorhabditis elegans/physiology , Chemotaxis/drug effects , Chemotaxis/physiology , Escherichia coli/drug effects , Escherichia coli/physiology , Ligands , Sensory Receptor Cells/drug effects , Signal Transduction
6.
Science ; 339(6121): 757, 2013 Feb 15.
Article in English | MEDLINE | ID: mdl-23413339

ABSTRACT

Edelaar raises concerns about the way we tested our theory. Our mathematical theorem predicts that despite the high dimensionality of trait space, trade-offs between tasks leads to phenotypes in low-dimensional regions in trait space, such as lines and triangles. We address Edelaar's questions with statistical tests that eliminate pseudoreplication concerns, finding that our predictions remain convincingly supported.


Subject(s)
Biological Evolution , Genetic Fitness , Phenotype , Animals
7.
Cell ; 143(2): 326-e1, 2010 Oct 15.
Article in English | MEDLINE | ID: mdl-20946989
8.
Proc Natl Acad Sci U S A ; 107(36): 15995-6000, 2010 Sep 07.
Article in English | MEDLINE | ID: mdl-20729472

ABSTRACT

Recent studies suggest that certain cellular sensory systems display fold-change detection (FCD): a response whose entire shape, including amplitude and duration, depends only on fold changes in input and not on absolute levels. Thus, a step change in input from, for example, level 1 to 2 gives precisely the same dynamical output as a step from level 2 to 4, because the steps have the same fold change. We ask what the benefit of FCD is and show that FCD is necessary and sufficient for sensory search to be independent of multiplying the input field by a scalar. Thus, the FCD search pattern depends only on the spatial profile of the input and not on its amplitude. Such scalar symmetry occurs in a wide range of sensory inputs, such as source strength multiplying diffusing/convecting chemical fields sensed in chemotaxis, ambient light multiplying the contrast field in vision, and protein concentrations multiplying the output in cellular signaling systems. Furthermore, we show that FCD entails two features found across sensory systems, exact adaptation and Weber's law, but that these two features are not sufficient for FCD. Finally, we present a wide class of mechanisms that have FCD, including certain nonlinear feedback and feed-forward loops. We find that bacterial chemotaxis displays feedback within the present class and hence, is expected to show FCD. This can explain experiments in which chemotaxis searches are insensitive to attractant source levels. This study, thus, suggests a connection between properties of biological sensory systems and scalar symmetry stemming from physical properties of their input fields.


Subject(s)
Systems Biology , Adaptation, Physiological
9.
Mol Cell ; 36(5): 894-9, 2009 Dec 11.
Article in English | MEDLINE | ID: mdl-20005851

ABSTRACT

Many sensory systems (e.g., vision and hearing) show a response that is proportional to the fold-change in the stimulus relative to the background, a feature related to Weber's Law. Recent experiments suggest such a fold-change detection feature in signaling systems in cells: a response that depends on the fold-change in the input signal, and not on its absolute level. It is therefore of interest to find molecular mechanisms of gene regulation that can provide such fold-change detection. Here, we demonstrate theoretically that fold-change detection can be generated by one of the most common network motifs in transcription networks, the incoherent feedforward loop (I1-FFL), in which an activator regulates both a gene and a repressor of the gene. The fold-change detection feature of the I1-FFL applies to the entire shape of the response, including its amplitude and duration, and is valid for a wide range of biochemical parameters.


Subject(s)
Gene Expression Regulation , Models, Theoretical , Signal Transduction
SELECTION OF CITATIONS
SEARCH DETAIL
...