Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Lab Med ; 27(1): 173-81, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17416310

ABSTRACT

With a focus on low-cost and low-power consumption, a miniature laser-induced fluorescence (LIF) detection system was assembled using a 635 nm red diode laser as the excitation source and a photodiode element coupled with an operational amplifier for signal collection. The primary elements of the miniature system, namely the laser and the detection system, cost a combined $70 and required only 270 mW of power for operation. When compared to conventional systems assembled using an argon-ion laser source and a photomultiplier tube, this represents a 98% decrease in the cost, and greater than 5000-fold decrease in power consumption. Quantitation of DNA on microdevices using the miniature LIF detection system was also performed with an error of less than 15%. This detection system is a step in the direction of commercializing microfluidic instrumentation by reducing the cost and power required for operation.


Subject(s)
DNA/analysis , Lasers , Microfluidic Analytical Techniques/economics , Microfluidic Analytical Techniques/instrumentation , Fluorescence , Microchemistry
2.
Article in English | MEDLINE | ID: mdl-15508276

ABSTRACT

Artificial blood substitutes (ABS) offer an alternative to donated blood. Increasing the oxygen carrying capacity of blood plasma through the addition of a Perfluorocarbon emulsion (PFE) is one approach in creating a blood substitute. The peripheral resistance of the circulatory system may be altered depending on the rheological properties of the ABS. Measurements of the rheological behavior of mixtures of a PFE, Oxygent, and erythrocyte suspensions were conducted at room temperature at different hematocrits using sheep (nonaggregating) and swine (aggregating) erythrocytes. The pure PFE was found to be shear thinning. Adding 6 and 12 g per 100 mL of sheep blood at the various hematocrits increased the viscosity of the suspension from as low as 4% (6 g PFE/40% Hct) to as high as 26.5% (12 g PFE/plasma). The nonaggregating sheep erythrocyte and PFE mixtures exhibited Newtonian behavior. Shear thinning behavior continued upon addition of 6 and 12 g per 100 mL of swine blood at the various hematocrits, with a slight increase in viscosity in most cases. It was observed that adding 12 g of PFE (approximately 3 x intended clinical dose) to 40% Hct swine blood at room temperature led to a significant decrease in viscosity.


Subject(s)
Blood Substitutes/chemistry , Erythrocyte Aggregation , Erythrocytes/chemistry , Fluorocarbons/chemistry , Animals , Hematocrit , Rheology , Sheep , Swine , Vascular Resistance , Viscosity
3.
Electrophoresis ; 24(7-8): 1261-70, 2003 Apr.
Article in English | MEDLINE | ID: mdl-12707920

ABSTRACT

The potential for using polyelectrolyte multilayers (PEMs) to provide chromatographic functionality on continuous silica networks created from sol-gel chemistry has been evaluated by capillary electrochromatography (CEC). Construction of the PEM was achieved by flushing the column with polyelectrolytes of alternative charge, with variation of the properties of the exposed polyelectrolyte providing a unique means to vary the chromatographic surface. Variation of the exposed polyelectrolyte from poly(diallyldimethylammonium chloride) (PDDAC) to dextran sulfate (DS) allowed the direction of the electroosmotic flow (EOF) to be changed and also provided a means to vary the chromatographic capacity. Variation of negative polymer from DS to poly(styrene sulfonate) (PSS) significantly altered the EOF and the migration of peptides, with both the reversed-phase and ion-exchange capacities increasing. An alternative method for changing the column capacity was to change the thickness of the PEM, which was evaluated by anion-exchange CEC. A 70-80% increase in retention was observed for all anions without any increase in EOF suggesting significant penetration of the analytes through the PEM and interaction with buried charges within the PEM.


Subject(s)
Electrophoresis, Capillary/instrumentation , Microfluidics/instrumentation , Dextran Sulfate , Miniaturization , Peptides/isolation & purification , Polyethylenes , Quaternary Ammonium Compounds , Rheology
4.
Electrophoresis ; 23(20): 3487-95, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12412116

ABSTRACT

Silica monolithic columns suitable for implementation on microchips have been evaluated by ion-exchange capillary electrochromatography. Two different silica monoliths were created from the alkyl silane, tetramethyl orthosilicate (TMOS), by introducing a water-soluble organic polymer, poly(ethylene oxide) (PEO), with varying molecular weights into the prehydrolyzed sol. Silica monoliths created using 10 kDa PEO were found to have a much more closed gel structure with a smaller percentage of pores in the microm size range than gels created using 100 kDa PEO. Additionally, the size of the mesopores in the 100 kDa PEO monolith was 5 nm, while those in the 10 kDa PEO gel were only 3 nm. This resulted in a strong dependence of the electroosmotic flow (EOF) on the ionic strength of the background electrolyte, with substantial pore flow through the nm size pores observed in the 10 kDa PEO gel. The chromatographic performance of the monolithic columns was evaluated by ion-exchange electrochromatography, with ion-exchange sites introduced via dynamic coating with the cationic polymer, poly(diallyldimethylammonium chloride) (PDDAC). Separating a mixture of inorganic anions, the 10 kDa PEO monolithic columns showed a higher effective capacity than the 100 kDa PEO column.


Subject(s)
Chromatography, Micellar Electrokinetic Capillary/instrumentation , Anions/isolation & purification , Chromatography, Ion Exchange/instrumentation , Chromatography, Ion Exchange/methods , Chromatography, Micellar Electrokinetic Capillary/methods , Miniaturization , Molecular Weight , Osmosis , Silica Gel , Silicon Dioxide
SELECTION OF CITATIONS
SEARCH DETAIL
...