Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Med ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951635

ABSTRACT

For centuries scientists and technologists have sought artificial leg replacements that fully capture the versatility of their intact biological counterparts. However, biological gait requires coordinated volitional and reflexive motor control by complex afferent and efferent neural interplay, making its neuroprosthetic emulation challenging after limb amputation. Here we hypothesize that continuous neural control of a bionic limb can restore biomimetic gait after below-knee amputation when residual muscle afferents are augmented. To test this hypothesis, we present a neuroprosthetic interface consisting of surgically connected, agonist-antagonist muscles including muscle-sensing electrodes. In a cohort of seven leg amputees, the interface is shown to augment residual muscle afferents by 18% of biologically intact values. Compared with a matched amputee cohort without the afferent augmentation, the maximum neuroprosthetic walking speed is increased by 41%, enabling equivalent peak speeds to persons without leg amputation. Further, this level of afferent augmentation enables biomimetic adaptation to various walking speeds and real-world environments, including slopes, stairs and obstructed pathways. Our results suggest that even a small augmentation of residual muscle afferents restores biomimetic gait under continuous neuromodulation in individuals with leg amputation.

2.
Biomimetics (Basel) ; 9(2)2024 Jan 26.
Article in English | MEDLINE | ID: mdl-38392122

ABSTRACT

Powered ankle prostheses have been proven to improve the walking economy of people with transtibial amputation. All commercial powered ankle prostheses that are currently available can only perform one-degree-of-freedom motion in a limited range. However, studies have shown that the frontal plane motion during ambulation is associated with balancing. In addition, as more advanced neural interfaces have become available for people with amputation, it is possible to fully recover ankle function by combining neural signals and a robotic ankle. Accordingly, there is a need for a powered ankle prosthesis that can have active control on not only plantarflexion and dorsiflexion but also eversion and inversion. We designed, built, and evaluated a two-degree-of-freedom (2-DoF) powered ankle-foot prosthesis that is untethered and can support level-ground walking. Benchtop tests were conducted to characterize the dynamics of the system. Walking trials were performed with a 77 kg subject that has unilateral transtibial amputation to evaluate system performance under realistic conditions. Benchtop tests demonstrated a step response rise time of less than 50 milliseconds for a torque of 40 N·m on each actuator. The closed-loop torque bandwidth of the actuator is 9.74 Hz. Walking trials demonstrated torque tracking errors (root mean square) of less than 7 N·m. These results suggested that the device can perform adequate torque control and support level-ground walking. This prosthesis can serve as a platform for studying biomechanics related to balance and has the possibility of further recovering the biological function of the ankle-subtalar-foot complex beyond the existing powered ankles.

3.
IEEE Trans Med Robot Bionics ; 3(3): 563-572, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34738079

ABSTRACT

For persons with lower extremity (LE) amputation, acquisition of surface electromyography (sEMG) from within the prosthetic socket remains a significant challenge due to the dynamic loads experienced during the gait cycle. However, these signals are critical for both understanding the clinical effects of LE amputation and determining the desired control trajectories of active LE prostheses. Current solutions for collecting within-socket sEMG are generally (i) incompatible with a subject's prescribed prosthetic socket and liners, (ii) uncomfortable, and (iii) expensive. This study presents an alternative within-socket sEMG acquisition paradigm using a novel flexible and low-profile electrode. First, the practical performance of this Sub-Liner Interface for Prosthetics (SLIP) electrode is compared to that of commercial Ag/AgCl electrodes within a cohort of subjects without amputation. Then, the corresponding SLIP electrode sEMG acquisition paradigm is implemented in a single subject with unilateral transtibial amputation performing unconstrained movements and walking on level ground. Finally, a quantitative questionnaire characterizes subjective comfort for SLIP electrode and commercial Ag/AgCl electrode instrumentation setups. Quantitative analyses suggest comparable signal qualities between SLIP and Ag/AgCl electrodes while qualitative analyses suggest the feasibility of using the SLIP electrode for real-time sEMG data collection from load-bearing, ambulatory subjects with LE amputation.

5.
J Neuroeng Rehabil ; 18(1): 38, 2021 02 17.
Article in English | MEDLINE | ID: mdl-33596960

ABSTRACT

BACKGROUND: Neuroprosthetic devices controlled by persons with standard limb amputation often lack the dexterity of the physiological limb due to limitations of both the user's ability to output accurate control signals and the control system's ability to formulate dynamic trajectories from those signals. To restore full limb functionality to persons with amputation, it is necessary to first deduce and quantify the motor performance of the missing limbs, then meet these performance requirements through direct, volitional control of neuroprosthetic devices. METHODS: We develop a neuromuscular modeling and optimization paradigm for the agonist-antagonist myoneural interface, a novel tissue architecture and neural interface for the control of myoelectric prostheses, that enables it to generate virtual joint trajectories coordinated with an intact biological joint at full physiologically-relevant movement bandwidth. In this investigation, a baseline of performance is first established in a population of non-amputee control subjects ([Formula: see text]). Then, a neuromuscular modeling and optimization technique is advanced that allows unilateral AMI amputation subjects ([Formula: see text]) and standard amputation subjects ([Formula: see text]) to generate virtual subtalar prosthetic joint kinematics using measured surface electromyography (sEMG) signals generated by musculature within the affected leg residuum. RESULTS: Using their optimized neuromuscular subtalar models under blindfolded conditions with only proprioceptive feedback, AMI amputation subjects demonstrate bilateral subtalar coordination accuracy not significantly different from that of the non-amputee control group (Kolmogorov-Smirnov test, [Formula: see text]) while standard amputation subjects demonstrate significantly poorer performance (Kolmogorov-Smirnov test, [Formula: see text]). CONCLUSIONS: These results suggest that the absence of an intact biological joint does not necessarily remove the ability to produce neurophysical signals with sufficient information to reconstruct physiological movements. Further, the seamless manner in which virtual and intact biological joints are shown to coordinate reinforces the theory that desired movement trajectories are mentally formulated in an abstract task space which does not depend on physical limb configurations.


Subject(s)
Algorithms , Artificial Limbs , Feedback, Sensory/physiology , Muscle, Skeletal/physiopathology , Psychomotor Performance/physiology , Adult , Amputation, Surgical , Biomechanical Phenomena , Electromyography/methods , Female , Humans , Male , Middle Aged , Models, Neurological , Movement/physiology , Signal Processing, Computer-Assisted , User-Computer Interface
6.
Article in English | MEDLINE | ID: mdl-34405057

ABSTRACT

Acquisition of surface electromyography (sEMG) from a person with an amputated lower extremity (LE) during prosthesis-assisted walking remains a significant challenge due to the dynamic nature of the gait cycle. Current solutions to sEMG-based neural control of active LE prostheses involve a combination of customized electrodes, prosthetic sockets, and liners. These technologies are generally: (i) incompatible with a subject's existing prosthetic socket and liners; (ii) uncomfortable to use; and (iii) expensive. This paper presents a flexible dry electrode design for sEMG acquisition within LE prosthetic sockets which seeks to address these issues. Design criteria and corresponding design decisions are explained and a proposed flexible electrode prototype is presented. Performances of the proposed electrode and commercial Ag/AgCl electrodes are compared in seated subjects without amputations. Quantitative analyses suggest comparable signal qualities for the proposed novel electrode and commercial electrodes. The proposed electrode is demonstrated in a subject with a unilateral transtibial amputation wearing her own liner, socket, and the portable sEMG processing platform in a preliminary standing and level ground walking study. Qualitative analyses suggest the feasibility of real-time sEMG data collection from load-bearing, ambulatory subjects.

SELECTION OF CITATIONS
SEARCH DETAIL
...