1.
Rev Sci Instrum ; 85(11): 11E425, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430332

ABSTRACT

The high resolution X-Ray crystal spectrometer at the JET tokamak has been upgraded with the main goal of measuring the tungsten impurity concentration. This is important for understanding impurity accumulation in the plasma after installation of the JET ITER-like wall (main chamber: Be, divertor: W). This contribution provides details of the upgraded spectrometer with a focus on the aspects important for spectral analysis and plasma parameter calculation. In particular, we describe the determination of the spectrometer sensitivity: important for impurity concentration determination.

2.
Phys Rev E Stat Nonlin Soft Matter Phys ; 83(3 Pt 2): 036402, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21517599

ABSTRACT

Ion and neutral parameters are determined in the high electron density, magnetized, hydrogen plasma beam of an ITER divertor relevant plasma via measurements of the n=2 excited neutrals. Ion rotation velocity (up to 7 km/s) and temperature (2-3 eV~T_{e}) are obtained from analysis of Hα spectra measured close to the plasma source. The methodology for neutral density determination is explained whereby measurements in the linear plasma beam of Pilot-PSI are compared to modeling. Ground-state atomic densities are obtained via the production rate of n=2 and the optical thickness of the Lyman-α transition (escape factor ~0.6) and yield an ionization degree >85% and dissociation degree in the residual gas of ~4%. A 30% proportion of molecules with a rovibrational excitation of more than 2 eV is deduced from the production rate of n=2 atoms. This proportion increases by more than a factor of 4 for a doubling of the electron density in the transition to ITER divertor relevant electron densities, probably because of a large increase in the production and confinement of ground-state neutrals. Measurements are made using laser-induced fluorescence (LIF) and absorption, the suitability of which are evaluated as diagnostics for this plasma regime. Absorption is found to have a much better sensitivity than LIF, mainly owing to competition with background emission.

3.
Phys Rev E Stat Nonlin Soft Matter Phys ; 78(4 Pt 2): 046405, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18999541

ABSTRACT

A potential buildup in front of a magnetized cascaded arc hydrogen plasma source is explored via E x B rotation and plate potential measurements. Plasma rotation approaches thermal speeds with maximum velocities of 10 km/s. The diagnostic for plasma rotation is optical emission spectroscopy on the Balmer-beta line. Asymmetric spectra are observed. A detailed consideration is given on the interpretation of such spectra with a two distribution model. This consideration includes radial dependence of emission determined by Abel inversion of the lateral intensity profile. Spectrum analysis is performed considering Doppler shift, Doppler broadening, Stark broadening, and Stark splitting.

4.
Rev Sci Instrum ; 79(1): 013505, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18248032

ABSTRACT

A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a "Generation III" image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n(e)) and 6% in the electron temperature (T(e)) at n(e) = 4 x 10(19) m(-3). This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9 x 10(17) m(-3) in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n(e) and T(e) measurement is 7 x 10(20)n(e) J, which means that single shot measurements are possible for n(e)>2 x 10(21) m(-3).