Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Med Dosim ; 44(1): 26-29, 2019.
Article in English | MEDLINE | ID: mdl-29395460

ABSTRACT

We aimed to analyze risk factors for incidents occurring during the practice of external beam radiotherapy (EBRT) at a single Japanese center. Treatment data for EBRT from June 2014 to March 2017 were collected. Data from incident reports submitted during this period were reviewed. Near-miss cases were not included. Risk factors for incidents, including patient characteristics and treatment-related factors, were explored using uni- and multivariate analyses. Factors contributing to each incident were also retrospectively categorized according to the recommendations of the American Association of Physicists in Medicine (AAPM). A total of 2887 patients were treated during the study period, and 26 incidents occurred (0.90% per patient). Previous history of radiotherapy and large fraction size were identified as risk factors for incidents by univariate analysis. Only previous history of radiotherapy was detected as a risk factor in multivariate analysis. Identified categories of contributing factors were human behavior (50.0%), communication (40.6%), and technical (9.4%). The incident rate of EBRT was 0.90% per patient in our institution. Previous history of radiotherapy and large fraction size were detected as risk factors for incidents. Human behavior and communication errors were identified as contributing factors for most incidents.


Subject(s)
Radiation Injuries/epidemiology , Radiotherapy/adverse effects , Aged , Female , Humans , Japan/epidemiology , Male , Radiation Injuries/etiology , Retrospective Studies , Risk Factors
2.
Phys Med Biol ; 63(14): 145002, 2018 07 09.
Article in English | MEDLINE | ID: mdl-29923497

ABSTRACT

The transportation accuracy of sealed radioisotope sources influences the therapeutic effect of high-dose-rate (HDR) brachytherapy. We have developed a pinhole imaging system for tracking an Ir-192 radiation source during HDR brachytherapy treatment. Our system consists of a dual-pinhole collimator, a scintillator, and a charge-coupled device (CCD) camera. We acquired stereo-shifted images to infer the source position in three dimensions using a dual pinhole collimator with 1.0 mm diameter pinholes. The CCD camera captured consecutive images of scintillation light that corresponds to the source positions every 2 s. The system automatically tracks scintillation light points using template-matching technique and measured the source positions therefrom. By integrating a series of CCD images, we could infer the source dwell time from the pixel values in the integrated image. We investigated the tracking accuracy of our system in monitoring simulated brachytherapy as it would be performed for cervical cancer by using water as a stand-in for human tissue. Ir-192 pellet was moved through a water tank using tandem and ovoid applicators. The CCD camera captured clear images of the scintillation light produced by the underwater Ir-192 source in conditions equivalent to common clinical situations. The differences between the measured and the reference 3D source positions and dwell times were 1.5 ± 0.7 mm and 0.8 ± 0.4 s, respectively. This system has the potential to track in vivo Ir-192 source in real time and may prove a useful tool for quality assurance during HDR brachytherapy treatments in clinical settings.


Subject(s)
Brachytherapy/methods , Image Processing, Computer-Assisted/methods , Iridium Radioisotopes/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Uterine Cervical Neoplasms/radiotherapy , Female , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Image-Guided/instrumentation
3.
Igaku Butsuri ; 37(3): 173-176, 2017.
Article in Japanese | MEDLINE | ID: mdl-29415959

ABSTRACT

High-dose-rate (HDR) brachytherapy is performed with the remote after-loading system (RALS) to transport an Ir-192 source directly to inside or near the tumor. Quality assurance (QA) of equipment should be performed at sufficient frequency to ensuring safety and quality of HDR brachytherapy treatment. Polymer gel dosimeters have been attracting attention in recent years as a QA tools of HDR brachytherapy, because they can measure the three-dimensional steep dose gradients around HDR sources. In this paper, we introduce our preliminary results using VIPET polymer gel dosimeters for Ir-192 HDR brachytherapy dosimetry.


Subject(s)
Brachytherapy , Iridium Radioisotopes , Polymers , Radiometry , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...