Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 20(9)2020 Apr 26.
Article in English | MEDLINE | ID: mdl-32357499

ABSTRACT

The quality of processed workpieces is affected directly by the precision of the linear stage. Therefore, the linear displacement calibration of machine tools must be implemented before delivery and after employment for a period of time. How to perform a precise calibration with high inspection efficiency is a critical issue in the precision mechanical engineering industry. In this study, the self-developed system integrated by the measurement module based on the common path Fabry-Pérot interferometer for linear displacement and the auto-alignment module for optical axes was proposed to realize the automatic linear displacement calibration of the linear stages. The measurement performance of the developed structure was verified experimentally. With the auto-alignment module, the cosine error was reduced to 0.36 nm and the entire procedure accomplished within 75 s without the limitation of the perceived resolution of the human eye, operational experience, and the risk of misalignment and broken cable. According to the comparison of experimental results for the linear displacement, the repeatability of the proposed measurement module was less than 0.171 µm. After the compensation procedure according to the linear displacement calibration, the systematic positional deviation, repeatability, and accuracy of the linear axis could be improved to 4 µm, 1 µm, and 5 µm respectively. Hence, the calibration efficiency can be improved by 80% with the proposed compact system, which is beneficial for the linear displacement calibration of machine tools in the precision mechanical engineering industry.

2.
Rev Sci Instrum ; 84(5): 053105, 2013 May.
Article in English | MEDLINE | ID: mdl-23742530

ABSTRACT

Laser interferometers have demonstrated outstanding measuring performances for high precision positioning or dimensional measurements in the precision industry, especially in the length measurement. Due to the non-common-optical-path structure, appreciable measurement errors can be easily induced under ordinary measurement conditions. That will lead to the limitation and inconvenience for in situ industrial applications. To minimize the environmental and mechanical effects, a new interferometric displacement measuring system with the common-optical-path structure and the resistance to tilt-angle is proposed. With the integration of optomechatronic modules in the novel interferometric system, the resolution up to picometer order, high precision, and ultra large measuring range have been realized. For the signal stabilization of displacement measurement, an automatic gain control module has been proposed. A self-developed interpolation model has been employed for enhancing the resolution. The novel interferometer can hold the advantage of high resolution and large measuring range simultaneously. By the experimental verifications, it has been proven that the actual resolution of 2.5 nm can be achieved in the measuring range of 500 mm. According to the comparison experiments, the maximal standard deviation of the difference between the self-developed Fabry-Perot interferometer and the reference commercial Michelson interferometer is 0.146 µm in the traveling range of 500 mm. With the prominent measuring characteristics, this should be the largest dynamic measurement range of a Fabry-Perot interferometer up till now.

3.
Appl Opt ; 52(17): 3902-9, 2013 Jun 10.
Article in English | MEDLINE | ID: mdl-23759837

ABSTRACT

Laser interferometers have been widely implemented for the displacement sensing and positioning calibration of the precision mechanical industry, due to their excellent measuring features and direct traceability to the dimensional definition. Currently some kinds of modified Fabry-Perot interferometers with a planar mirror or a corner cube prism as the measurement mirror have been proposed. Each optical structure of both models has the individual particularity and performance for measuring applications. In this investigation, a multi-interferometric displacement system has been proposed whose measurement mirror can be quickly and conveniently altered with a planar mirror or a corner cube reflector depending on the measuring demand. Some experimental results and analyses about the interpolation error and displacement measurements with both reflectors have been demonstrated. According to the results, suggestions about the choice of a measuring reflector and interpolation model have been presented. With the measuring verifications, the developed system with a maximum standard deviation less than 0.2081 µm in measuring range of 300 mm would be a compact and robust tool for sensing or calibrating the linear displacement of mechanical equipment.

4.
Rev Sci Instrum ; 82(6): 063103, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21721670

ABSTRACT

Fabry-Perot interferometer is often used for the micro-displacement, because of its common optical path structure being insensitive to the environmental disturbances. Recently, the folded Fabry-Perot interferometer has been investigated for displacement measurements in large ranges. The advantages of a folded Fabry-Perot interferometer are insensitive to the tilt angle and higher optical resolution. But the design of the optical cavity has become more and more complicated. For this reason, the intensity loss in the cavity will be an important parameter for the distribution of the interferometric intensity. To obtain a more accurate result of such interferometer utilized for displacement measurements, the intensity loss of the cavity in the fabricated folded Fabry-Perot interferometer and the modified equation of the folded Fabry-Perot interferometer will be described. According to the theoretical and experimental results, the presented model is available for the analysis of displacement measurements by a folded Fabry-Perot interferometer.

5.
Rev Sci Instrum ; 81(9): 093102, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20886971

ABSTRACT

The optical configuration of a Fabry-Pérot interferometer is uncomplicated. This has already been applied in different measurement systems. For the displacement measurement with the Fabry-Pérot interferometer, the result is significantly influenced by the tilt angles of the measurement mirror in the interferometer. Hence, only for the rather small measuring range, the Fabry-Pérot interferometer is available. The goal of this investigation is to enhance the measuring range of Fabry-Pérot interferometer by compensating the tilt angles. To verify the measuring characteristic of the self-developed Fabry-Pérot interferometer, some comparison measurements with a reference standard have been performed. The maximum deviation of comparison experiments is less than 0.3 µm in the traveling range of 30 mm. The experimental results show that the Fabry-Pérot interferometer is highly stable, insensitive to environment effects, and can meet the measuring requirement of the submicrometer order.

6.
Sensors (Basel) ; 10(4): 2577-86, 2010.
Article in English | MEDLINE | ID: mdl-22319261

ABSTRACT

The optical structure of general commercial interferometers, e.g., the Michelson interferometers, is based on a non-common optical path. Such interferometers suffer from environmental effects because of the different phase changes induced in different optical paths and consequently the measurement precision will be significantly influenced by tiny variations of the environmental conditions. Fabry-Perot interferometers, which feature common optical paths, are insensitive to environmental disturbances. That would be advantageous for precision displacement measurements under ordinary environmental conditions. To verify and analyze this influence, displacement measurements with the two types of interferometers, i.e., a self-fabricated Fabry-Perot interferometer and a commercial Michelson interferometer, have been performed and compared under various environmental disturbance scenarios. Under several test conditions, the self-fabricated Fabry-Perot interferometer was obviously less sensitive to environmental disturbances than a commercial Michelson interferometer. Experimental results have shown that induced errors from environmental disturbances in a Fabry-Perot interferometer are one fifth of those in a Michelson interferometer. This has proved that an interferometer with the common optical path structure will be much more independent of environmental disturbances than those with a non-common optical path structure. It would be beneficial for the solution of interferometers utilized for precision displacement measurements in ordinary measurement environments.

SELECTION OF CITATIONS
SEARCH DETAIL
...