Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Hand (N Y) ; : 15589447231151434, 2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36752100

ABSTRACT

BACKGROUND: Revision of radial head arthroplasty (RHA) may be indicated in cases of prosthesis loosening and malposition. Inherent difficulties in revision surgery include poor bone stock and disrupted soft tissue envelope. Although cases of RHA used for revision of failed RHA are rare, there is reasonable expectation for increasing frequency of these cases due to the increasing incidence of primary RHA. Furthermore, there is an increasing demand for postoperative recovery of function; thus, surgeons may consider revising a failed RHA to a new RHA. We report on series of failed RHA which were revised to a new radial head prosthesis. METHODS: A retrospective review was performed at multiple institutions for a single radial head prosthesis used for revision of a failed radial head prosthesis. Clinical and radiographic outcomes were collected with a minimum of 1 year of follow-up. RESULTS: Across 11 patients at a mean follow-up of 45.1 months, the mean Mayo Elbow Performance Score was 81.7; mean Disabilities of the Arm, Shoulder, and Hand scores were 24.4; and mean Visual Analog Scale for pain was 0.6. Radiographic analysis yielded no evidence of capitellar wear or stem loosening. CONCLUSION: A radial head prosthesis can produce satisfactory results when used for revision of a failed prosthesis. Inherent difficulties in revision surgery include the potential for reduced bone stock and a disrupted soft tissue envelope. Elements of prosthesis design which may contribute to effectively managing revision surgery include a long stem with in-growth surface and prosthetic head alignment to the axis of forearm rotation.

2.
J Hand Surg Am ; 40(7): 1446-8, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25986652
3.
Orthopedics ; 36(9): e1169-74, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24025009

ABSTRACT

Certain metacarpal fracture patterns require operative fixation to restore anatomy and optimize results. Compared with dorsal plating, the width of the minicondylar blade plate buttresses the deforming volar pull of the intrinsics and provides a stronger construct. The implant provides firm fixation in the juxta-articular fragment with minimal space requirements. Therefore, the purpose of this study was to examine the outcomes following the use of a minicondylar blade plate for the treatment of distal metacarpal fractures. Twenty-two distal metacarpal fractures in 20 patients treated with a minicondylar blade plate were retrospectively reviewed. Outcome measures collected included postoperative grip strength, range of motion, return to work, and radiographic evidence of osseous union. Average range of motion of the metacarpophalangeal joint was 62° postoperatively. Eighty-two percent (18/22) of fractures were able to flex their digits to their distal palmar crease. Seventy-one percent (12/17) of patients had at least 75% return to grip strength compared with the contralateral side. Seventeen patients returned to full activity at a mean of 2.5 months (range, 1-3 months) postoperatively; 1 patient was on disability, and data were not available for the final 2 patients. No major complications occurred. The minicondylar blade plate is a safe and effective technique for stabilizing unstable periarticular metacarpal fractures. Stable fixation allows for early range of motion, rapid return to strength, and a relatively quick return to full work duty.


Subject(s)
Bone Plates , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Metacarpal Bones/injuries , Wrist Injuries/surgery , Adolescent , Adult , Aged , Female , Follow-Up Studies , Fractures, Bone/diagnostic imaging , Humans , Male , Metacarpal Bones/diagnostic imaging , Metacarpal Bones/surgery , Middle Aged , Radiography , Retrospective Studies , Treatment Outcome , Wrist Injuries/diagnostic imaging , Young Adult
4.
Orthopedics ; 36(8): e1096-8, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23937760

ABSTRACT

Despite prevention efforts, burn injuries among auto mechanics are described in the literature. Electrothermal ring burns from car batteries occur by short-circuiting through the ring when it touches the open terminal or metal housing. This article describes a 34-year-old male auto mechanic who was holding a wrench when his gold ring touched the positive terminal of a 12-volt car battery and the wrench touched both his ring and the negative terminal. He felt instant pain and had a deep partial-thickness circumferential burn at the base of his ring finger. No other soft tissues were injured. He was initially managed conservatively, but after minimal healing at 3 weeks, he underwent a full-thickness skin graft. The graft incorporated well and healed by 4 weeks postoperatively. He had full range of motion. The cause of ring burns has been controversial, but based on reports similar to the current patient's mechanism, they are most likely electrothermal burns. Gold, a metal with high thermal conductivity, can heat up to its melting point in a matter of seconds. Many treatments have been described, including local wound care to split- and full-thickness skin grafts. Because most burns are preventable, staff should be warned and trained about the potential risks of contact burns. All jewelry should be removed, and the live battery terminal should be covered while working in the vicinity of the battery.


Subject(s)
Automobiles , Burns, Electric/etiology , Burns, Electric/surgery , Electric Power Supplies , Finger Injuries/etiology , Finger Injuries/surgery , Skin Transplantation/methods , Adult , Burns, Electric/diagnosis , Finger Injuries/diagnosis , Humans , Male , Treatment Outcome
5.
Orthopedics ; 35(8): e1286-9, 2012 Aug 01.
Article in English | MEDLINE | ID: mdl-22868623

ABSTRACT

Acute carpal tunnel syndrome is an uncommon diagnosis most often related to blunt trauma requiring immediate surgical decompression to avoid serious sequelae. Patients who present with bleeding-related acute carpal tunnel syndrome tend to have severe pain, rapid onset of swelling, and neurologic symptoms that appear early and progress rapidly secondary to mass effect. Acute carpal tunnel syndrome can occur in anticoagulated patients spontaneously or after minor trauma. This article describes a case of a 57-year-old man with progressive pain and paresthesias in the median nerve distribution after reaching for a picture frame. He was taking dabigatran, a direct thrombin inhibitor, for atrial fibrillation. He developed acute carpal tunnel syndrome secondary to spontaneous bleeding into the carpal canal and flexor tenosynovium with hematoma formation requiring surgical decompression. He reported immediate pain relief postoperatively, had no further bleeding complications, and regained full median nerve function within 2 months.Dabigatran has gained recent popularity for the treatment of atrial fibrillation. Unlike warfarin, its use does not involve regular laboratory monitoring or dose titration. The risks and benefits of dabigatran should be considered carefully by the prescriber, particularly in patients taking medications that may alter its metabolism. Aspirin and nonsteroidal anti-inflammatory drugs may have effects similar to dabigatran and may increase the risk of bleeding problems. Should acute carpal tunnel syndrome occur, the authors recommend prompt surgical decompression rather than conservative management. The modification of anticoagulant therapy should be considered on a case-by-case basis.


Subject(s)
Antithrombins/adverse effects , Benzimidazoles/adverse effects , Carpal Tunnel Syndrome/chemically induced , Hematoma/chemically induced , beta-Alanine/analogs & derivatives , Acute Disease , Carpal Tunnel Syndrome/etiology , Carpal Tunnel Syndrome/surgery , Dabigatran , Decompression, Surgical , Hematoma/etiology , Hematoma/surgery , Humans , Male , Middle Aged , beta-Alanine/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...