Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Can Assoc Radiol J ; 72(4): 736-741, 2021 Nov.
Article in English | MEDLINE | ID: mdl-32903020

ABSTRACT

OBJECTIVE: Ultra-low radiation dose computed tomography (CT) abdominal tomography was introduced in our institution in 2016 to replace standard abdominal radiography in the investigation of emergency department patients. This project aims to ascertain whether investigation of emergency department patients using ultra-low radiation dose CT abdominal tomography complies with original indication guidelines and/or if there has been any "indication creep" 3 years after inception. METHODS: Retrospective, quality assurance project with research ethics waiver. A review of 200 consecutive patients investigated with CT abdominal tomography between February and May 2017 was performed. This was compared with 200 consecutive patients investigated between February and May 2019. Data analyzed included patient demographics, indication for scan, as well as scan and patient outcomes. RESULTS: In the 2017 group, 29/200 scans were noncompliant with approved indication guidelines. In the 2019 group, 30/200 scans were also noncompliant. There was no statistically significant difference between groups (P < .05) regarding the use of approved indications. Forty of 200 scans performed in 2017 revealed additional findings which are not specifically addressed on the reporting template. Forty-one of 200 scans in 2019 revealed these findings. CONCLUSIONS: There has been no "indication creep" for CT abdominal tomography over time.


Subject(s)
Guideline Adherence/statistics & numerical data , Quality Assurance, Health Care/methods , Radiography, Abdominal/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Aged , Emergency Service, Hospital , Female , Humans , Male , Quality Assurance, Health Care/statistics & numerical data , Radiation Dosage , Radiography, Abdominal/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
2.
J Acoust Soc Am ; 148(4): EL326, 2020 10.
Article in English | MEDLINE | ID: mdl-33138500

ABSTRACT

The study examines whether non-native listeners leverage their L2 lexicon during a phonetic identification task and whether lexical bias is influenced by word position and length. Native English and native Mandarin speakers were tested on English words where the natural sibilant was replaced by one member of a nine-step [s]/[ʃ] continuum. English speakers experience a lexical bias effect for longer words. No clear bias was observed for Mandarin participants, although age of arrival correlated with amount of lexical bias but only in the initial position of longer words. These results suggest that language proficiency and higher-order linguistic representations drive perception.


Subject(s)
Language , Multilingualism , Speech Perception , Humans , Phonetics
3.
J Vasc Surg Cases Innov Tech ; 6(1): 93-95, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32095664

ABSTRACT

Bronchial artery aneurysm (BAA) is a rare vascular abnormality that may result in life-threatening bleeding if it is left untreated. We present the case of a 35-year-old man with a mediastinal BAA characterized by a short inflow artery segment and tortuous single outflow vessel. The patient's BAA was treated with a novel approach involving placement of a patent ductus arteriosus closure device in the short inflow segment as well as coil embolization of the outflow vessel, successfully excluding the BAA. Two-week follow-up revealed no flow in the embolized artery on computed tomography angiography. This case demonstrates the first successful use of a patent ductus arteriosus occluder device in the treatment of a mediastinal BAA with short inflow segment.

SELECTION OF CITATIONS
SEARCH DETAIL
...