1.
Philos Trans A Math Phys Eng Sci ; 373(2043)2015 Jun 13.
Article in English | MEDLINE | ID: mdl-25939620

ABSTRACT

We introduce phase-diagram analysis, a standard tool in compressed sensing (CS), to the X-ray computed tomography (CT) community as a systematic method for determining how few projections suffice for accurate sparsity-regularized reconstruction. In CS, a phase diagram is a convenient way to study and express certain theoretical relations between sparsity and sufficient sampling. We adapt phase-diagram analysis for empirical use in X-ray CT for which the same theoretical results do not hold. We demonstrate in three case studies the potential of phase-diagram analysis for providing quantitative answers to questions of undersampling. First, we demonstrate that there are cases where X-ray CT empirically performs comparably with a near-optimal CS strategy, namely taking measurements with Gaussian sensing matrices. Second, we show that, in contrast to what might have been anticipated, taking randomized CT measurements does not lead to improved performance compared with standard structured sampling patterns. Finally, we show preliminary results of how well phase-diagram analysis can predict the sufficient number of projections for accurately reconstructing a large-scale image of a given sparsity by means of total-variation regularization.


Subject(s)
Algorithms , Data Compression/methods , Models, Statistical , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Computer Simulation , Data Interpretation, Statistical , Humans , Reproducibility of Results , Sample Size , Sensitivity and Specificity
2.
Med Phys ; 39(6Part28): 3973, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28519635

ABSTRACT

PURPOSE: The adoption of C-arm cone-beam CT (CBCT) can minimize interruption to the interventional workflow. However, C-arm gantry rotation can be susceptible to gravity and mechanical instability, therefore resulting images with contamination of tilting and wobbling motion. The purpose of this work is to investigate and demonstrate potential improvement of C-arm CBCT images by tailoring and applying an innovative iterative algorithm that can fully incorporate accurate scanning geometry. METHODS: A clinical C-arm CBCT system (Toshiba Infinix-i, Japan) was used for collecting projection data of a patient's brain with aneurysm. A mask scan was performed before contrast was injected, and a contrast scan was performed during continuous contrast feeding. During each scan, 108 projections were acquired over a range of approximately 200 degrees within about 4.6 seconds. Logarithm subtraction was then carried out view by view to obtain 108 projections of virtually only the vasculature. An iterative algorithm, referred to as the ASD-POCS algorithm, was modified to fully incorporate calibration data characterizing the actual scan geometry that deviates from a circular trajectory due to gantry tilting and wobbling. We then applied both FDK and ASD-POCS algorithms to reconstructing image from the acquired patient data. RESULTS: In FDK reconstructions without considering C-arm tilting and wobbling motion, artifacts can be observed, which break vessel continuity and compromise image's clinical utility. We then performed FDK reconstructions by incorporating the system geometry in the back-projection step and obtained improved vessel continuity. Finally we applied the ASD- POCS algorithm by incorporating calibration data in the forward- and back- projector, and obtained reconstructions with further improvement on the recovery of small, secondary vascular branches. CONCLUSIONS: Appropriately developed iterative algorithms can improve C-arm CBCT image quality by fully incorporating scanning geometry, and can potentially enable spatial-resolution demanding applications which can be challenging to achieve with the FDK algorithm.

3.
Rev Sci Instrum ; 82(4): 043706, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21529012

ABSTRACT

Synchrotron-radiation-based microcomputed-tomography (SR-µCT) is a powerful tool for yielding 3D structural information of high spatial and contrast resolution about a specimen preserved in its natural state. A large number of projection views are required currently for yielding SR-µCT images by use of existing algorithms without significant artifacts. When a wet biological specimen is imaged, synchrotron x-ray radiation from a large number of projection views can result in significant structural deformation within the specimen. A possible approach to reducing imaging time and specimen deformation is to decrease the number of projection views. In the work, using reconstruction algorithms developed recently for medical computed tomography (CT), we investigate and demonstrate image reconstruction from sparse-view data acquired in SR-µCT. Numerical results of our study suggest that images of practical value can be obtained from data acquired at a number of projection views significantly lower than those used currently in a typical SR-µCT imaging experiment.


Subject(s)
Image Processing, Computer-Assisted/methods , Synchrotrons , X-Ray Microtomography/instrumentation , Algorithms , Reference Standards , X-Ray Microtomography/standards
4.
IEEE Nucl Sci Symp Conf Rec (1997) ; 2009: 3458-3462, 2009 Jan 01.
Article in English | MEDLINE | ID: mdl-21318098

ABSTRACT

Flying-focal-spot (FFS) technique has been used for improving the sampling condition in advanced clinical CT by collecting multiple cone-beam data sets with the focal-spot at different locations at each "projection view". It has been demonstrated that the increased sampling rate in FFS scans can substantially reduce aliasing artifacts in reconstructed images. However, the increase of the sampling density through multiple illuminations at each view can result in the increase of radiation dose to the imaged subject. In this work, we have applied a compressive-sensing (CS)-based algorithm to image reconstruction from data acquired in FFS scans. The results of the study demonstrate that aliasing artifacts observed images reconstructed by use of analytic algorithms can be suppressed effectively in images reconstructed with this CS-based algorithm from only data acquired at one FFS scan.

SELECTION OF CITATIONS