1.
Neth Heart J ; 21(9): 417-9, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23605477

ABSTRACT

We report the occurrence of coronary vasospasm following forceful compression of the brachial artery after coronary angiography.

2.
Echocardiography ; 17(7): 625-9, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11107198

ABSTRACT

UNLABELLED: Homografts and stentless xenografts are increasingly used in aortic valve surgery. Echocardiography technicians and cardiologists have to know what they will find when performing an echo-Doppler examination in patients who received a stentless valve. We therefore evaluated echocardiographic images of 74 patients who received a Freestyle stentless bioprosthesis with three techniques and a follow-up of 2 years in two high-volume hospitals. Of the patients studied, 81% were operated using the subcoronary technique, 12% using the root-inclusion technique, and 7% using the full-root technique. RESULTS: Transvalvular gradients across the stentless valves were low: 8.0 mmHg when implanted with the subcoronary technique, 8.2 +/- 5.1 mmHg using the root-inclusion technique, and 6.5 mmHg using the full-root technique. Trivial aortic insufficiency (grade 1) was observed in 10.7% of the patients (8.9% for the subcoronary technique, 13% for the root-inclusion technique, and 0% for the full-root technique). When the bioprosthesis was implanted using the subcoronary technique or the root-inclusion technique, the prosthesis was placed inside the recipient aortic root. Using these techniques, a lumen between the double layer of the xenograft and the aortic wall could be observed. With the root-replacement technique, the porcine root became the most proximal part of the ascending aorta. As the native aortic wall was removed, in most cases, no double lumen could be observed with imaging of the ascending aorta.


Subject(s)
Aortic Valve , Bioprosthesis , Echocardiography , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Bioprosthesis/adverse effects , Follow-Up Studies , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Time Factors
3.
J Am Soc Echocardiogr ; 12(9): 729-35, 1999 Sep.
Article in English | MEDLINE | ID: mdl-10477417

ABSTRACT

The objective of this study was to determine normal Doppler and 2-dimensional characteristics of the Freestyle stentless aortic bioprosthesis. The Freestyle aortic bioprosthesis is a new type of aortic xenograft, and experience is limited. We therefore determined the normal range of echocardiographic and Doppler examinations of this valve. Three hundred thirty-nine consecutive patients with a Freestyle aortic bioprosthesis underwent an echocardiographic and Doppler examination according to a common protocol. Investigations were done within 4 weeks after operation, after 3 to 6 months, and after 1, 2, and 3 years. With a valve size from 19 to 27 mm, mean gradients decreased from 7.9 +/- 5.1 mm Hg at discharge to 5.5 +/- 3. 8 mm Hg after 3 to 6 months (P <.001). Thereafter, gradients remained stable. Effective orifice area 1 year after implantation was 1.59 +/- 0.58 cm(2) for the 21-mm valves, 1.92 +/- 0.74 cm(2) for the 23-mm valves, 2.03 +/- 0.64 cm(2) for the 25-mm valves, and 2.52 +/- 0.72 cm(2) for the 27-mm valves (P <.001). The performance index, the ratio of the measured effective orifice area in the patient divided by the effective orifice area measured in vitro, increased from 67% +/- 20% at discharge to 82% +/- 29% after 1, 2, and 3 years. Performance index was especially very high in the smaller-sized valves. After implantation with the subcoronary technique or root-inclusion technique, small cavities could be seen between the native aortic root and the Freestyle valve. Doppler values were evaluated for the Freestyle stentless porcine bioprostheses in the aortic root. Gradients appear to be close to those measured in native valves over a time period of 3 years.


Subject(s)
Bioprosthesis , Echocardiography, Doppler , Heart Valve Diseases/diagnostic imaging , Heart Valve Prosthesis , Adolescent , Adult , Aged , Aged, 80 and over , Aortic Valve , Europe , Humans , Middle Aged , Prosthesis Design