Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Eur J Clin Nutr ; 78(6): 509-514, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38454153

ABSTRACT

BACKGROUND: The precision of digital anthropometry through 3-dimensional (3D) scanning has been established for relatively large, expensive, non-portable systems. The comparative performance of modern mobile applications is unclear. SUBJECTS/METHODS: Forty-six adults (age: 23.3 ± 5.3 y; BMI: 24.4 ± 4.1 kg/m2) were assessed in duplicate using: (1) a mobile phone application capturing two individual 2D images, (2) a mobile phone application capturing serial images collected during a subject's complete rotation, (3) a traditional scanner with a time of flight infrared sensor collecting visual data from a subject being rotated on a mechanical turntable, and (4) a commercial measuring booth with structured light technology using 20 infrared depth sensors positioned in the booth. The absolute and relative technical error of measurement (TEM) and intraclass correlation coefficient (ICC) for each method were established. RESULTS: Averaged across circumferences, the absolute TEM, relative TEM, and ICC were (1) 0.9 cm, 1.5%, and 0.975; (2) 0.5 cm, 0.9%, and 0.986; (3) 0.8 cm, 1.5%, and 0.974; and (4) 0.6 cm, 1.1%, and 0.985. For total body volume, these values were (1) 2.2 L, 3.0%, and 0.978; (2) 0.8 L, 1.1%, and 0.997; (3) 0.7 L, 0.9%, and 0.998; and (4) 0.8 L, 1.1%, and 0.996, with segmental volumes demonstrating higher relative errors. CONCLUSION: A 3D scanning mobile phone application involving full rotation of subjects in front of a smartphone camera exhibited similar reliability to larger, less portable, more expensive 3D scanners. In contrast, larger errors were observed for a mobile scanning application utilizing two 2D images, although the technical errors were acceptable for some applications.


Subject(s)
Anthropometry , Imaging, Three-Dimensional , Mobile Applications , Humans , Adult , Male , Female , Anthropometry/methods , Anthropometry/instrumentation , Young Adult , Imaging, Three-Dimensional/methods , Cell Phone , Reproducibility of Results , Adolescent
2.
Sports Med ; 54(2): 473-484, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37776465

ABSTRACT

BACKGROUND: Assessing certainty of evidence is a key element of any systematic review. The aim of this meta-epidemiology study was to understand the frequency and ways with which certainty of evidence is assessed in contemporary systematic reviews published in high-impact sports science journals. METHODS: We searched PubMed and relevant journal web sites from 1 August 2016 to 11 October 2022 for systematic reviews published in the top-ten highest-impact journals within the 2020 Journal Citation Report for the Sports Sciences category. Pairs of independent reviewers screened items using a priori established criteria. RESULTS: Of 1250 eligible documents, 258 (20.6%) assessed the certainty of evidence, defined as using two or more distinct domains to provide an overall rating of the trustworthiness of findings across studies. Nine methods were cited for assessing certainty, with the most common being the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach (61.6%). The proportion of systematic reviews assessing certainty of evidence appeared to increase over the 6-year timeframe analyzed. Across all reviews analyzed, a large majority addressed the domains of risk of bias, imprecision, and inconsistency of the results. Other certainty domains including indirectness/applicability were less commonly assessed. DISCUSSION: Only one in five recent contemporary systematic reviews in the field of exercise and sports science assessed certainty of evidence. Organizational and institutional education on methods for assessing evidence may help further increase uptake of these methods and improve both the quality and clinical impact of systematic reviews in the field.


Subject(s)
Periodicals as Topic , Sports , Humans , Systematic Reviews as Topic , Bias , Epidemiologic Studies
3.
Nutrients ; 15(22)2023 Nov 17.
Article in English | MEDLINE | ID: mdl-38004200

ABSTRACT

Multi-ingredient thermogenic supplements can acutely increase resting energy expenditure (REE) and subjective energy. However, less is understood about the effects of chronic consumption on body composition, metabolism, and subjective variables such as mood, sleep quality, and eating behaviors. Fifty-two healthy, exercise-trained participants (50% female; mean ± SD age: 23.5 ± 3.0 years; body fat percentage: 27.3 ± 8.0%) were randomized 2:2:1 to take a whey protein supplement alone (PRO; n = 20), in combination with a thermogenic supplement (PRO + FB; n = 19), or no supplement at all (CON; n = 13) for four weeks. Body composition, anthropometric, metabolic, hemodynamic, and subjective outcomes were collected before and after the intervention. Greater changes in REE occurred in PRO + FB as compared to CON (111.2 kcal/d, 95% CI 2.4 to 219.9 kcal/d, p = 0.04), without significant differences between PRO and CON (42.7 kcal/d, 95% CI -65.0 to 150.3 kcal/d, p = 0.61) or between PRO + FB and PRO (68.5 kcal/d, 95% CI -28.3, 165.3, p = 0.21). No changes in hemodynamic outcomes (blood pressure and heart rate) were observed. In exercising adults, four weeks of supplementation with protein and a multi-ingredient thermogenic product maintained fasted REE as compared to no supplementation, for which a decrease in REE was observed, without differential effects on body composition, anthropometrics, or subjective variables.


Subject(s)
Dietary Supplements , Energy Metabolism , Adult , Humans , Female , Young Adult , Male , Body Composition , Anthropometry , Hemodynamics
4.
J Acad Nutr Diet ; 2023 Sep 22.
Article in English | MEDLINE | ID: mdl-37742826

ABSTRACT

BACKGROUND: Pre-exercise meal frequency is commonly believed to impact exercise performance, but little is known about its impact on resistance training. OBJECTIVE: This study investigated the impact of breakfast consumption on afternoon resistance training performance in habitual breakfast consumers and nonconsumers. DESIGN: A randomized, crossover study was conducted in Lubbock, TX between November 2021 and May 2022. PARTICIPANTS: Thirty-nine resistance-trained male (n = 20) and female (n = 19) adults (mean ± SD age 23.0 ± 4.7 years) who habitually consumed (≥5 d/wk; n = 19) or did not consume (≥5 d/wk; n = 20) breakfast completed the study. INTERVENTION: After the establishment of 1-repetition maximums at the first visit, participants completed 2 additional visits, each of which included 4 sets of barbell back squat, bench press, and deadlift, using 80% of their 1-repetition maximum after either consuming breakfast and lunch or the same food at lunch only. MAIN OUTCOME MEASURES: Repetitions, along with average and peak average concentric velocity and power, were measured for all repetitions throughout each exercise session. Visual analog scales were used to assess feelings of fatigue, energy, focus, hunger, desire to eat, and fullness throughout each exercise session. STATISTICAL ANALYSES PERFORMED: Data were analyzed using linear mixed-effects models. RESULTS: No interactions or main effects involving condition or habitual breakfast consumption were observed for resistance training outcomes, although sex differences were noted. Male participants performed significantly fewer repetitions on sets 2, 3, and 4 (P < .014) for total repetitions, on sets 2 and 4 for barbell back squat (P < .023), and set 4 for deadlift (P = .006), with no observed differences between sexes for bench press repetitions. Male participants displayed reductions in average power across all sets and exercises except deadlift. CONCLUSIONS: These data suggest that alterations in pre-exercise meal frequency may not influence afternoon resistance training performance provided similar total nutritional intake is consumed.

5.
Eur J Clin Nutr ; 77(12): 1151-1159, 2023 12.
Article in English | MEDLINE | ID: mdl-37591970

ABSTRACT

BACKGROUND/OBJECTIVES: Skeletal muscle mass (SMM) estimation is important but challenging in clinical settings. Criterion methods, such as magnetic resonance imaging (MRI), are often inaccessible. However, surrogate methods, such as dual-energy X-ray absorptiometry (DXA) and multi-frequency bioelectrical impedance analysis (MFBIA), can use MRI-based equations to estimate SMM, although the agreement between these methods is unclear. SUBJECTS/METHODS: Total and segmental SMM were estimated with DXA and MFBIA using MRI-based equations in 313 healthy adults (120 M, 193 F; age 30.2 ± 13.0 y; BMI 24.6 ± 4.0 kg/m2). DXA total SMM was estimated using the Kim and McCarthy equations, and segmental SMM was estimated using the McCarthy equations. Relationships between DXA and MFBIA SMM were examined using Deming regression, Lin's concordance correlation coefficient (CCC), equivalence testing, Bland-Altman analysis, and related tests. RESULTS: Strong linear relationships were observed for total (R2 0.95, CCC 0.96-0.97), leg (R2 0.90, CCC 0.85) and arm (R2 0.93, CCC 0.93) SMM in the entire sample. Kim equation SMM demonstrated statistical equivalence with MFBIA for total SMM, but the Deming regression slope differed from 1 and proportional bias was present. McCarthy equation total SMM exhibited a regression slope that did not differ from 1, and no proportional bias was present in the entire sample. However, equivalence with MFBIA was not observed. Systematically higher leg and arm SMM values were observed with DXA as compared to MFBIA. CONCLUSIONS: While DXA and MFBIA total SMM generally exhibited strong agreement, higher appendicular SMM by DXA highlights technical differences between methods.


Subject(s)
Body Composition , Muscle, Skeletal , Adult , Humans , Adolescent , Young Adult , Absorptiometry, Photon/methods , Electric Impedance , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Magnetic Resonance Imaging
6.
J Electr Bioimpedance ; 14(1): 3-12, 2023 Jan.
Article in English | MEDLINE | ID: mdl-37416523

ABSTRACT

This study evaluated the influence of novel beverage formulations on bioimpedance- and urine-based hydration markers. Thirty young healthy adults (n=16 females, n=14 males; age: 23.2±3.7 years; BMI: 24.3±3.3 kg/m2) participated in a randomized, double-blind, placebo-controlled, crossover study. Participants completed three conditions with baseline bioimpedance, urine, and body mass assessments, followed by ingestion of one liter of a test beverage over a 30-minute period. The three beverages were: active hydration formulation in still (AFstill) or sparkling (AFspark) water and a still water control. The active formulations were identical in concentrations of alpha-cyclodextrin and complexing agents. Following beverage ingestion, bioimpedance assessments were performed every 15 minutes for two hours, followed by final urinary and body mass assessments. The primary bioimpedance outcomes were phase angle at 50 kHz, resistance of the extra-cellular compartment (R0), and resistance of the intracellular compartment (Ri). Data were analyzed using linear mixed effects models, Friedman tests, and Wilcoxon tests. Statistically significant changes in phase angle values were observed at 30 (p=0.004) and 45 minutes (p=0.024) following the initiation of beverage ingestion in the AFstill condition as compared to the reference model (i.e., control condition at baseline). Although differences between conditions were not statistically significant at later time points, the data were consistent with AFstill having greater elevations in phase angle throughout the monitoring period. At the 30-minute time point only, statistically significant differences in R0 for AFspark (p<0.001) and in Ri for AFstill (p=0.008) were observed. When averaged across post-ingestion time points, there was a trend (p=0.08) for Ri differences between conditions. The net fluid balance was greater than zero, indicating retention of ingested fluid, for AFstill (p=0.02) and control (p=0.03), with a trend for AFspark (p=0.06). In conclusion, an active formulation containing alpha-cyclodextrin in still water demonstrated potential benefits for enhancing hydration markers in humans.

7.
Int J Exerc Sci ; 16(1): 429-447, 2023.
Article in English | MEDLINE | ID: mdl-37123458

ABSTRACT

The purpose of this preliminary analysis was to determine if there are relationships between anthropometric characteristics (arm length, torso length, thigh length, and shank length) and conventional deadlift (CDL) kinematics and kinetics during a 5 sets of 5 repetitions (5 × 5) CDL routine in resistance-trained males. Eleven males who had experience with the deadlift exercise were included in this analysis (age: 21.5 ± 1.4 y; height: 180.7 ± 5.7 cm; body mass: 89.9 ± 16.0 kg). Anthropometrics were measured by a 3-dimensional optical scanner. The participants underwent a 5 × 5 CDL workout using a self-selected load corresponding to a rating of perceived exertion (RPE) of 8 out of 10. Performance outcomes were measured synchronously using a 3-dimensional 12-camera motion capture system and two force platforms. Outcomes were averaged across all sets and analyzed using multiple linear regression. The selected anthropometric variables were not significantly related to the CDL performance outcomes, except for concentric ankle work. However, in the overall model, anthropometric predictors did not significantly predict ankle concentric work (p = 0.11; R 2 = 0.67; R_2adj = 0.45). Independently, thigh length significantly correlated with ankle concentric work (p = 0.03). In this model, thigh length accounted for 55% of the normalized variance in ankle concentric work. The results from this preliminary study suggest that arm length, torso length, and shank length may not play a clear role in the examined CDL outcomes, but thigh length may be positively correlated with ankle concentric work during a 5 × 5 CDL routine in resistance-trained males.

8.
J Hum Kinet ; 86: 117-132, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37181269

ABSTRACT

The purpose of this study was to examine the effects of intermittent versus continuous energy restriction on body composition, resting metabolic rate, and eating behaviors in resistance-trained females. Thirty-eight resistance-trained females (mean ± standard deviation age: 22.3 ± 4.2 years) were randomized to receive either six weeks of a continuous 25% reduction in energy intake (n = 18), or one week of energy balance after every two weeks of 25% energy restriction (eight weeks total; n = 20). Participants were instructed to ingest 1.8 g protein/kilogram bodyweight per day and completed three weekly supervised resistance training sessions throughout the intervention. There were no differences between groups for changes over time in body composition, resting metabolic rate, or seven of the eight measured eating behavior variables (p > 0.05). However, a significant group-by-time interaction for disinhibition (p < 0.01) from the Three-Factor Eating Questionnaire was observed, with values (± standard error) in the continuous group increasing from 4.91 ± 0.73 to 6.17 ± 0.71, while values in the intermittent group decreased from 6.80 ± 0.68 to 6.05 ± 0.68. Thus, diet breaks do not appear to induce improvements in body composition or metabolic rate in comparison with continuous energy restriction over six weeks of dieting, but may be employed for those who desire a short-term break from an energy-restricted diet without fear of fat regain. While diet breaks may reduce the impact of prolonged energy restriction on measures of disinhibition, they also require a longer time period that may be less appealing for some individuals.

9.
J Int Soc Sports Nutr ; 20(1): 2211958, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37162193

ABSTRACT

BACKGROUND: Thermogenic supplements are often consumed by individuals seeking to improve energy levels and reduce body fat. These supplements are sold in powdered or ready-to-drink (RTD) forms and consist of a blend of ingredients such as caffeine, green tea extract, and other botanical compounds. While there is evidence that thermogenic supplements can positively affect resting energy expenditure (REE), the effect varies based on the combination of active ingredients. Additionally, there is some concern that thermogenic supplements may cause unwanted side effects on hemodynamic variables, like heart rate (HR) and blood pressure (BP). Therefore, further investigation into the efficacy and safety of commercially available products is warranted. METHODS: Twenty-eight individuals (14 F, 14 M; age: 23.3 ± 3.9 yrs; height: 169.4 ± 8.6 cm; body mass: 73.3 ± 13.1 kg) completed two visits in a randomized, double-blind, crossover fashion. Each visit began with baseline REE, HR, and BP assessments, which were followed by ingestion of an active RTD thermogenic beverage (RTD; OxyShred Ultra Energy) or placebo (PL). Assessments were repeated at the intervals of 35-50- and 85-100-minutes post-ingestion. In addition, subjective outcomes of energy, focus, concentration, alertness, and mood were collected five times throughout each visit. Repeated-measures analysis of variance was performed with condition and time specified as within-subjects factors and sex and resistance training (RT) status as between-subjects factors. Statistical significance was accepted at p < 0.05. RESULTS: A significant condition × time interaction was observed for REE (p < 0.001). Higher REE values were demonstrated at 35-50 min (0.08 ± 0.02 kcal/min; p = 0.001; 5.2% difference) and 85-100 min (0.08 ± 0.02 kcal/min; p = 0.001; 5.5% difference) after RTD ingestion as compared to PL. No significant condition × time interactions were observed for respiratory quotient, HR, or BP. Condition main effects indicated lower HR (3.0 ± 0.9 bpm; p = 0.003), higher SBP (3.5 ± 1.1 mm Hg; p = 0.003) and higher DBP (3.5 ± 0.9 mm Hg; p < 0.001) in RTD as compared to PL, irrespective of time. Condition × time interactions were observed for all subjective outcomes (p ≤ 0.02). Post hoc tests indicated statistically significant benefits of the RTD over PL for energy, focus, concentration, and alertness, without significant differences for mood after correction for multiple comparisons. Sex and RT status were not involved in interactions for any outcomes, except for a Sex × RT status interaction for energy, indicating higher energy ratings in non-resistance-trained vs. resistance-trained males. CONCLUSIONS: These data suggest that acute ingestion of a thermogenic RTD beverage significantly increases REE, and this elevated caloric expenditure is sustained for at least 100 minutes following ingestion. Furthermore, the RTD beverage increased measures of energy, focus, concentration, and alertness as compared to placebo. While minor differences in hemodynamic variables were observed between conditions, all values stayed within normal ranges. Individuals aiming to increase energy expenditure may benefit from acute ingestion of an RTD thermogenic supplement.


Subject(s)
Energy Metabolism , Hemodynamics , Male , Humans , Young Adult , Adult , Blood Pressure , Heart Rate , Beverages , Double-Blind Method , Cross-Over Studies
10.
Sports Med ; 53(8): 1507-1526, 2023 08.
Article in English | MEDLINE | ID: mdl-37213050

ABSTRACT

Resting metabolic rate (RMR) is a significant contributor to an individual's total energy expenditure. As such, RMR plays an important role in body weight regulation across populations ranging from inactive individuals to athletes. In addition, RMR may also be used to screen for low energy availability and energy deficiency in athletes, and thus may be useful in identifying individuals at risk for the deleterious consequences of chronic energy deficiency. Given its importance in both clinical and research settings within the fields of exercise physiology, dietetics, and sports medicine, the valid assessment of RMR is critical. However, factors including varying states of energy balance (both short- and long-term energy deficit or surplus), energy availability, and prior food intake or exercise may influence resulting RMR measures, potentially introducing error into observed values. The purpose of this review is to summarize the relationships between short- and long-term changes in energetic status and resulting RMR measures, consider these findings in the context of relevant recommendations for RMR assessment, and provide suggestions for future research.


Subject(s)
Basal Metabolism , Energy Metabolism , Humans , Basal Metabolism/physiology , Energy Metabolism/physiology , Body Weight , Exercise/physiology , Athletes , Energy Intake , Body Composition
11.
Br J Nutr ; 130(5): 827-840, 2023 09 14.
Article in English | MEDLINE | ID: mdl-36404739

ABSTRACT

The purpose of this investigation was to expand upon the limited existing research examining the test-retest reliability, cross-sectional validity and longitudinal validity of a sample of bioelectrical impedance analysis (BIA) devices as compared with a laboratory four-compartment (4C) model. Seventy-three healthy participants aged 19-50 years were assessed by each of fifteen BIA devices, with resulting body fat percentage estimates compared with a 4C model utilising air displacement plethysmography, dual-energy X-ray absorptiometry and bioimpedance spectroscopy. A subset of thirty-seven participants returned for a second visit 12-16 weeks later and were included in an analysis of longitudinal validity. The sample of devices included fourteen consumer-grade and one research-grade model in a variety of configurations: hand-to-hand, foot-to-foot and bilateral hand-to-foot (octapolar). BIA devices demonstrated high reliability, with precision error ranging from 0·0 to 0·49 %. Cross-sectional validity varied, with constant error relative to the 4C model ranging from -3·5 (sd 4·1) % to 11·7 (sd 4·7) %, standard error of the estimate values of 3·1-7·5 % and Lin's concordance correlation coefficients (CCC) of 0·48-0·94. For longitudinal validity, constant error ranged from -0·4 (sd 2·1) % to 1·3 (sd 2·7) %, with standard error of the estimate values of 1·7-2·6 % and Lin's CCC of 0·37-0·78. While performance varied widely across the sample investigated, select models of BIA devices (particularly octapolar and select foot-to-foot devices) may hold potential utility for the tracking of body composition over time, particularly in contexts in which the purchase or use of a research-grade device is infeasible.


Subject(s)
Body Composition , Humans , Reproducibility of Results , Electric Impedance , Cross-Sectional Studies , Absorptiometry, Photon/methods
13.
Nutrients ; 14(16)2022 Aug 13.
Article in English | MEDLINE | ID: mdl-36014827

ABSTRACT

Multivitamin/mineral (MVM) supplements are one of the most popular dietary supplement categories. The purpose of this analysis was to determine if a novel liposomal delivery mechanism improves mineral absorption from an MVM product. In a randomized crossover trial, 25 healthy participants (12 females, 13 males) completed two testing sessions in which blood samples were collected at baseline and 2, 4, and 6 h following the ingestion of either a liposomal MVM or a nutrient-matched standard MVM. Analysis of MVM products indicated an elemental iron content of 9.4 and 10.1 mg (~50% U.S. FDA Daily Value) and an elemental magnesium content of 22.0 and 23.3 mg (~5% U.S. FDA Daily Value) in the liposomal and standard MVM products, respectively. Blood samples were analyzed for concentrations of iron and magnesium using colorimetric assays. Changes in mineral concentrations were analyzed using linear mixed models, and pharmacokinetic parameters were compared between conditions. For iron, statistically significant condition × time interactions were observed for percent change from baseline (p = 0.002), rank of percent change from baseline (p = 0.01), and raw concentrations (p = 0.02). Follow-up testing indicated that the liposomal condition exhibited larger changes from baseline than the standard MVM condition at 4 (p = 0.0001; +14.3 ± 18.5% vs. -6.0 ± 13.1%) and 6 h (p = 0.0002; +1.0 ± 20.9% vs. -21.0 ± 15.3%) following MVM ingestion. These changes were further supported by a 50% greater mean incremental area under the curve in the liposomal condition (33.2 ± 30.9 vs. 19.8 ± 19.8 mcg/dL × 6 h; p = 0.02, Cohen's d effect size = 0.52). In contrast, no differential effects for magnesium absorption were observed. In conclusion, iron absorption from an MVM product is enhanced by a liposomal delivery mechanism.


Subject(s)
Magnesium , Minerals , Cross-Over Studies , Dietary Supplements , Female , Humans , Iron , Male , Vitamins
15.
J Int Soc Sports Nutr ; 19(1): 126-149, 2022.
Article in English | MEDLINE | ID: mdl-35599920

ABSTRACT

Background: There is substantial consumer and practitioner interest in an emerging supplement class known as multi-ingredient pre-workout supplements (MIPS), largely due to their prevalence in resistance training communities as well as research findings demonstrating the ergogenic impact of caffeine on muscular performance. However, limited research has examined the potential efficacy of non-caffeinated MIPS, despite their growing popularity among those who are caffeine-sensitive or who train later in the day. Methods: Twenty-four resistance-trained college-aged males (n = 12) and females (n = 12) completed three visits in which they ingested either a caffeinated MIPS (C), an otherwise identical non-caffeinated MIPS (NC), or placebo in a double-blind, counterbalanced, crossover fashion. Squat isometric peak force (PFiso), rate of force development (RFD), and isokinetic performance were assessed. Upper and lower body maximal muscular strength and endurance were evaluated using the bench press and leg press, respectively. Visual analog scales for energy, focus, and fatigue were completed five times throughout the testing protocol. The effects of supplementation and biological sex on all variables were examined using linear mixed effects models. Results: Significantly greater PFiso was observed in both C (b: 0.36 transformed units [0.09, 0.62]) and NC (b: 0.32 transformed units [95% CI: 0.05, 0.58]) conditions, relative to placebo. Early RFD (RFD50) may have been higher with supplementation, particularly in females, with no effects for late RFD (RFD200) or peak RFD. In addition, increases in subjective energy after supplement ingestion were noted for C, but not NC. No effects of supplementation on traditional resistance exercise performance or isokinetic squat performance were observed, other than a lower leg press one-repetition maximum for males in the NC condition. Conclusions: These data indicate that acute ingestion of either a caffeinated or non-caffeinated pre-workout formulation improved maximal force production during an isometric squat test but did not provide additional benefit to leg press, bench press, or isokinetic squat performance over placebo, within the context of a laboratory environment. The consumption of a caffeinated, but not non-caffeinated, MIPS increased subjective ratings of energy over placebo when assessed as part of a testing battery.


Subject(s)
Performance-Enhancing Substances , Resistance Training , Caffeine/pharmacology , Dietary Supplements , Double-Blind Method , Female , Humans , Male , Muscle Strength , Performance-Enhancing Substances/pharmacology , Resistance Training/methods , Sports Nutritional Physiological Phenomena , Young Adult
16.
J Strength Cond Res ; 36(6): 1498-1505, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35333210

ABSTRACT

ABSTRACT: Lewis, MH, Siedler, MR, Lamadrid, P, Ford, S, Smith, T, SanFilippo, G, Waddell, B, Trexler, ET, Buckner, S, and Campbell, BI. Sex differences may exist for performance fatigue but not recovery after single-joint upper-body and lower-body resistance exercise. J Strength Cond Res 36(6): 1498-1505, 2022-This study evaluated sex differences in performance recovery and fatigue during dynamic exercise. Twenty-eight resistance-trained males (n = 16) and females (n = 12) completed a repeated-measures, randomized, parallel-groups design. The protocol consisted of a baseline assessment, a recovery period (4, 24, or 48 hours), and a postrecovery assessment. The assessments were identical consisting of 4 sets of 10 repetition maximum (10RM) bicep curls and 4 sets of 10RM leg extensions to failure. Recovery was quantified as the number of total repetitions completed in the postrecovery bout. Fatigue was quantified as the number of repetitions completed set to set within the session. For analysis, we set the level of significance at p ≤ 0.05. No sex differences in performance recovery were observed across any of the investigated time periods for either exercise modality. Regarding fatigue, significant effects were observed for set (p < 0.001) and sex (p = 0.031) for bicep curls. Repetitions dropped in later sets, and females generally completed a greater number of repetitions than males (8.8 ± 0.5 vs. 7.2 ± 0.5). For leg extension, a significant sex × set interaction was observed (p = 0.003), but post hoc tests revealed these sex differences as marginal. Our results suggest that in dynamic bicep curls and leg extensions, other factors unrelated to sex may be more impactful on performance recovery. To optimize an athlete's desired adaptations, it may be more important to consider other variables unrelated to sex such as volume, perceived exertion, and training history when formulating training prescriptions for single-joint exercises.


Subject(s)
Resistance Training , Exercise , Fatigue , Female , Humans , Male , Muscle, Skeletal , Resistance Training/methods , Sex Characteristics
17.
Nutr Rev ; 80(3): 439-452, 2022 02 10.
Article in English | MEDLINE | ID: mdl-35142356

ABSTRACT

Intermittent fasting (IF) is a dietary strategy that involves alternating periods of abstention from calorie consumption with periods of ad libitum food intake. There is significant interest in the body of literature describing longitudinal adaptations to IF. Less attention has been given to the acute physiological responses that occur during the fasting durations that are commonly employed by IF practitioners. Thus, the purpose of this review was to examine the physiological responses - including alterations in substrate metabolism, systemic hormones, and autophagy - that occur throughout an acute fast. Literature searches were performed to locate relevant research describing physiological responses to acute fasting and short-term starvation. A single fast demonstrated the ability to alter glucose and lipid metabolism within the initial 24 hours, but variations in protein metabolism appeared to be minimal within this time frame. The ability of an acute fast to elicit significant increases in autophagy is still unknown. The information summarized in this review can be used to help contextualize existing research and better inform development of future IF interventions.


Subject(s)
Energy Intake , Fasting , Blood Glucose , Diet , Fasting/physiology , Glucose , Humans , Lipid Metabolism
18.
J Gen Intern Med ; 37(11): 2669-2677, 2022 08.
Article in English | MEDLINE | ID: mdl-34545466

ABSTRACT

BACKGROUND: The development of rigorous, high-quality clinical guidelines increases the need for resources and skilled personnel within guideline-producing organizations. While collaboration between organizations provides a unique opportunity to pool resources and save time and effort, the collaboration presents its own unique challenges. OBJECTIVE: To assess the perceived needs and current challenges of guideline producers worldwide related to guideline development and collaboration efforts. DESIGN: Survey questions were developed by the Guidelines International Network and the US GRADE Network, pilot-tested among attendees of a guideline development workshop, and disseminated electronically using convenience and snowball sampling methods. PARTICIPANTS: A total of 171 respondents representing 30 countries and more than 112 unique organizations were included in this analysis. MAIN MEASURES: The survey included free-response, multiple-choice, and seven-point Likert-scale questions. Questions assessed respondents' perceived value of guidelines, resource availability and needs, guideline development processes, and collaboration efforts of their organization. KEY RESULTS: Time required to develop high-quality systematic reviews and guidelines was the most relevant need (median=7; IQR=5.5-7). In-house resources to conduct literature searches (median=4; IQR=3-6) and the resources to develop rigorous guidelines rapidly (median=4; IQR=2-5) were perceived as the least available resources. Difficulties reconciling differences in guideline methodology (median=6; IQR=4-7) and the time required to establish collaborative agreements (median=6; IQR=5-6) were the most relevant barriers to collaboration between organizations. Results also indicated a general need for improvement in conflict of interest (COI) disclosure policies. CONCLUSION: The survey identified organizational challenges in supporting rigorous guideline development, including the time, resources, and personnel required. Connecting guideline developers to existing databases of high-quality systematic reviews and the use of freely available online platforms may facilitate guideline development. Guideline-producing organizations may also consider allocating resources to hiring or training personnel with expertise in systematic review methodologies or utilizing resources more effectively by establishing collaborations with other organizations.


Subject(s)
Conflict of Interest , Evidence-Based Medicine , Disclosure , Evidence-Based Medicine/methods , Humans , Needs Assessment , Surveys and Questionnaires
19.
J Strength Cond Res ; 36(11): 3093-3104, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-34172636

ABSTRACT

ABSTRACT: Rodriguez, C, Harty, PS, Stratton, MT, Siedler, MR, Smith, RW, Johnson, BA, Dellinger, JR, Williams, AD, White, SJ, Benavides, ML, and Tinsley, GM. Comparison of indirect calorimetry and common prediction equations for evaluating changes in resting metabolic rate induced by resistance training and a hypercaloric diet. J Strength Cond Res 36(11): 3093-3104, 2022-The ability to accurately identify resting metabolic rate (RMR) changes over time allows practitioners to prescribe appropriate adjustments to nutritional intake. However, there is a lack of data concerning the longitudinal utility of commonly used RMR prediction equations. The purpose of this study was to evaluate the validity of several commonly used prediction equations to track RMR changes during a hypercaloric nutritional intervention and supervised resistance exercise training program. Twenty resistance-trained men completed the study. The protocol lasted 6 weeks, and subjects underwent RMR assessments by indirect calorimetry (IC) preintervention and postintervention to obtain reference values. Existing RMR prediction equations based on body mass (BM) or dual-energy X-ray absorptiometry fat-free mass (FFM) were also evaluated. Equivalence testing was used to evaluate whether each prediction equation demonstrated equivalence with IC. Null hypothesis significance testing was also performed, and Bland-Altman analysis was used alongside linear regression to assess the degree of proportional bias. Body mass and FFM increased by 3.6 ± 1.7 kg and 2.4 ± 1.6 kg, respectively. Indirect calorimetry RMR increased by 165 ± 97 kcal·d -1 , and RMR:FFM increased by 5.6 ± 5.2%. All prediction equations underestimated mean RMR changes relative to IC, with magnitudes ranging from 75 to 155 kcal·d -1 , while also displaying unacceptable levels of negative proportional bias. In addition, no equation demonstrated equivalence with IC. Common RMR prediction equations based on BM or FFM did not fully detect the increase in RMR observed with resistance training plus a hypercaloric diet. Overall, the evaluated prediction equations are unsuitable for estimating RMR changes in the context of this study.


Subject(s)
Basal Metabolism , Resistance Training , Male , Humans , Calorimetry, Indirect/methods , Absorptiometry, Photon , Diet , Body Composition
20.
Br J Nutr ; 127(11): 1656-1674, 2022 06 14.
Article in English | MEDLINE | ID: mdl-34325758

ABSTRACT

The present study reports the validity of multiple assessment methods for tracking changes in body composition over time and quantifies the influence of unstandardised pre-assessment procedures. Resistance-trained males underwent 6 weeks of structured resistance training alongside a hyperenergetic diet, with four total body composition evaluations. Pre-intervention, body composition was estimated in standardised (i.e. overnight fasted and rested) and unstandardised (i.e. no control over pre-assessment activities) conditions within a single day. The same assessments were repeated post-intervention, and body composition changes were estimated from all possible combinations of pre-intervention and post-intervention data. Assessment methods included dual-energy X-ray absorptiometry (DXA), air displacement plethysmography, three-dimensional optical imaging, single- and multi-frequency bioelectrical impedance analysis, bioimpedance spectroscopy and multi-component models. Data were analysed using equivalence testing, Bland-Altman analysis, Friedman tests and validity metrics. Most methods demonstrated meaningful errors when unstandardised conditions were present pre- and/or post-intervention, resulting in blunted or exaggerated changes relative to true body composition changes. However, some methods - particularly DXA and select digital anthropometry techniques - were more robust to a lack of standardisation. In standardised conditions, methods exhibiting the highest overall agreement with the four-component model were other multi-component models, select bioimpedance technologies, DXA and select digital anthropometry techniques. Although specific methods varied, the present study broadly demonstrates the importance of controlling and documenting standardisation procedures prior to body composition assessments across distinct assessment technologies, particularly for longitudinal investigations. Additionally, there are meaningful differences in the ability of common methods to track longitudinal body composition changes.


Subject(s)
Body Composition , Humans , Male , Electric Impedance , Reproducibility of Results , Anthropometry/methods , Absorptiometry, Photon/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...