1.
Int J Comput Assist Radiol Surg ; 18(9): 1571-1575, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37058232

ABSTRACT

PURPOSE: A robotic assistive device is developed for needle-based percutaneous interventions. The aim is a hybrid system using both manual and actuated robotic operation in order to obtain a device that has a large workspace but can still fit in the gantry opening of a CT scanner. This will enable physicians to perform precise and time-efficient CT-guided percutaneous interventions. The concept of the mechanics and software of the device is presented in this work. METHODS: The approach is a semi-automated robotic assistive device, which combines manual and robotic positioning to reduce the number and size of necessary motors. The system consists of a manual rough positioning unit, a robotic fine positioning unit and an optical needle tracking unit. The resulting system has eight degrees of freedom, of which four are manual, which comprise encoders to monitor the position of each axis. The remaining four axes are actuated axes for fine positioning of the needle. Cameras are attached to the mechanical structure for 3D tracking of the needle pose. The software is based on open-source software, mainly ROS2 as robotic middleware, Moveit2 for trajectory calculation and 3D Slicer for needle path planning. RESULTS: The communication between the components was successfully tested with a clinical CT scanner. In a first experiment, four needle insertions were planned and the deviation of the actual needle path from the planned path was measured. The mean deviation from the needle path to the target point was 21.9 mm, which is mainly caused both by translational deviation (15.4 mm) and angular deviation (6.8°) of the needle holder. The optical tracking system was able to detect the needle position with a mean deviation of 3.9 mm. CONCLUSION: The first validation of the system was successful which proves that the proposed concept for both the hardware and software is feasible. In a next step, an automatic position correction based on the optical tracking system will be integrated, which is expected to significantly improve the system accuracy.


Subject(s)
Robotic Surgical Procedures , Robotics , Humans , Robotic Surgical Procedures/methods , Tomography, X-Ray Computed/methods , Needles , Software , Phantoms, Imaging
2.
Med Phys ; 46(12): 5488-5498, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31587313

ABSTRACT

PURPOSE: Three-dimensional (3D) printing allows for the fabrication of medical devices with complex geometries, such as soft actuators and robots that can be used in image-guided interventions. This study investigates flexible and rigid 3D-printing materials in terms of their impact on multimodal medical imaging. METHODS: The generation of artifacts in clinical computer tomography (CT) and magnetic resonance (MR) imaging was evaluated for six flexible and three rigid materials, each with a cubical and a cylindrical geometry, and for one exemplary flexible fluidic actuator. Additionally, CT Hounsfield units (HU) were quantified for various parameter sets iterating peak voltage, x-ray tube current, slice thickness, and convolution kernel. RESULTS: We found the image artifacts caused by the materials to be negligible in both CT and MR images. The HU values mainly depended on the elemental composition of the materials and applied peak voltage was ranging between 80 and 140 kVp. Flexible, nonsilicone-based materials were ranged between 51 and 114 HU. The voltage dependency was less than 29 HU. Flexible, silicone-based materials were ranged between 60 and 365 HU. The voltage-dependent influence was as large as 172 HU. Rigid materials ranged between -69 and 132 HU. The voltage-dependent influence was <33 HU. CONCLUSIONS: All tested materials may be employed for devices placed in the field of view during CT and MR imaging as no significant artifacts were measured. Moreover, the material selection in CT could be based on the desired visibility of the material depending on the application. Given the wide availability of the tested materials, we expect our results to have a positive impact on the development of devices and robots for image-guided interventions.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Mechanical Phenomena , Printing, Three-Dimensional , Robotics , Tomography, X-Ray Computed/instrumentation , Artifacts , Equipment Design