Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Anaesthesiol Scand ; 60(1): 93-102, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26251260

ABSTRACT

BACKGROUND: Currently 80% of donor lungs are not accepted for transplantation, often due to fluid overload. Our aim was to investigate if forced fluid infusion may be replaced by a new pharmacological therapy to stabilize circulation after brain death in an animal model, and to assess therapy effects on lung function and morphology trough blood gas parameters and state-of-the-art High-resolution CT (HRCT). METHODS: Brain death was caused by surgical decapitation. To maintain mean aortic pressure > 60 mmHg, pigs were treated with forced electrolyte solution infusion (GI; n = 6) or the pharmacological therapy (GII; n = 11). GIII (n = 11) were non-decapitated controls. Lung function was investigated with blood gases and lung morphology with HRCT. RESULTS: GI pigs became circulatory instable 4-6 h after brain death in spite of forced fluid infusion, five pigs showed moderate to severe pulmonary edema on HRCT and median final PaO2 /FiO2 was 29 kPa (Q1; Q3; range 26; 40; 17-76). GII and GIII were circulatory stable (mean aortic pressure > 80 mmHg) and median final PaO2 /FiO2 after 24 h was 72 kPa (Q1; Q3; range 64; 76; 53-91) (GII) and 66 kPa (55; 78; 43-90) (GIII). On HRCT, only two pigs in GII had mild pulmonary edema and none in GIII. More than 50% of HRCT exams revealed unexpected lung disease even in spite of PaO2 /FiO2 > 40 kPa. CONCLUSION: Pharmacological therapy but not forced fluid infusion prevented circulatory collapse and extensive HRCT verified pulmonary edema after acute brain death. HRCT was useful to evaluate lung morphology and revealed substantial occult parenchymal changes justifying efforts toward a more intense use of HRCT in the pre-transplant evaluation.


Subject(s)
Blood Circulation , Brain Death/diagnosis , Lung/diagnostic imaging , Animals , Blood Gas Analysis , Decapitation , Electrolytes/administration & dosage , Electrolytes/therapeutic use , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Oxygen/blood , Positive-Pressure Respiration , Pulmonary Edema/physiopathology , Respiration, Artificial , Sus scrofa , Swine , Tomography, X-Ray Computed
2.
Eur J Radiol ; 84(5): 757-64, 2015 May.
Article in English | MEDLINE | ID: mdl-25048978

ABSTRACT

Different radiological methods play an important role in the work-up of patients complaining of spine pain. Depending on the symptoms and the suspected underlying etiology different methods are selected. In the following presentation we briefly present the different radiological and magnetic resonance tomography methods that are at hand, give some guidance in which method to use, and present the typical imaging findings in some of the most common conditions that presents with spine pain.


Subject(s)
Back Pain/etiology , Magnetic Resonance Imaging , Spinal Diseases/diagnosis , Spinal Injuries/diagnosis , Tomography, X-Ray Computed , Female , Fluoroscopy , Humans , Male , Myelography , Practice Guidelines as Topic , Spinal Diseases/complications , Spinal Injuries/complications
4.
Br J Radiol ; 86(1031): 20130388, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24049128

ABSTRACT

OBJECTIVE: To evaluate the image quality produced by six different iterative reconstruction (IR) algorithms in four CT systems in the setting of brain CT, using different radiation dose levels and iterative image optimisation levels. METHODS: An image quality phantom, supplied with a bone mimicking annulus, was examined using four CT systems from different vendors and four radiation dose levels. Acquisitions were reconstructed using conventional filtered back-projection (FBP), three levels of statistical IR and, when available, a model-based IR algorithm. The evaluated image quality parameters were CT numbers, uniformity, noise, noise-power spectra, low-contrast resolution and spatial resolution. RESULTS: Compared with FBP, noise reduction was achieved by all six IR algorithms at all radiation dose levels, with further improvement seen at higher IR levels. Noise-power spectra revealed changes in noise distribution relative to the FBP for most statistical IR algorithms, especially the two model-based IR algorithms. Compared with FBP, variable degrees of improvements were seen in both objective and subjective low-contrast resolutions for all IR algorithms. Spatial resolution was improved with both model-based IR algorithms and one of the statistical IR algorithms. CONCLUSION: The four statistical IR algorithms evaluated in the study all improved the general image quality compared with FBP, with improvement seen for most or all evaluated quality criteria. Further improvement was achieved with one of the model-based IR algorithms. ADVANCES IN KNOWLEDGE: The six evaluated IR algorithms all improve the image quality in brain CT but show different strengths and weaknesses.


Subject(s)
Algorithms , Brain/diagnostic imaging , Phantoms, Imaging , Radiation Dosage , Radiographic Image Enhancement/methods , Humans , Models, Theoretical , Neuroimaging , Radiation Protection/methods , Radiographic Image Enhancement/instrumentation , Tomography, X-Ray Computed/methods
5.
Rhinology ; 50(1): 26-32, 2012 03.
Article in English | MEDLINE | ID: mdl-22469602

ABSTRACT

PROBLEM: Suspected, but objectively absent, rhinosinusitis constitutes a major cause of visits to the doctor, high health care costs, and the over-prescription of antibiotics, contributing to the serious problem of resistant bacteria. This situation is largely due to a lack of reliable and widely applicable diagnostic methods. METHOD: A novel method for the diagnosis of rhinosinusitis based on non-intrusive diode laser gas spectroscopy is presented. The technique is based on light absorption by free gas (oxygen and water vapour) inside the sinuses, and has the potential to be a complementary diagnostic tool in primary health care. The method was evaluated on 40 patients with suspected sinus problems, referred to the diagnostic radiology clinic for low-dose computed tomography (CT), which was used as the reference technique. MAIN RESULTS: The data obtained with the new laser-based method correlated well with the grading of opacification and ventilation using CT. The sensitivity and specificity were estimated to be 93% and 61%, respectively, for the maxillary sinuses, and 94% and 86%, respectively, for the frontal sinuses. Good reproducibility was shown. PRINCIPAL CONCLUSION: The laser-based technique presents real-time clinical data that correlate well to CT findings, while being non-intrusive and avoiding the use of ionizing radiation.


Subject(s)
Frontal Sinusitis/diagnosis , Lasers, Semiconductor , Maxillary Sinusitis/diagnosis , Rhinitis/diagnosis , Spectrum Analysis , Adult , Aged , Aged, 80 and over , Female , Frontal Sinusitis/diagnostic imaging , Humans , Male , Maxillary Sinusitis/diagnostic imaging , Middle Aged , Rhinitis/diagnostic imaging , Sensitivity and Specificity , Tomography, X-Ray Computed , Young Adult
6.
Neurology ; 77(7): 623-30, 2011 Aug 16.
Article in English | MEDLINE | ID: mdl-21775743

ABSTRACT

OBJECTIVE: Therapeutic hypothermia (TH) is a recommended treatment for survivors of cardiac arrest. Prognostication is complicated since sedation and muscle relaxation are used and established indicators of a poor prognosis are lacking. This prospective, observational study describes the pattern of commonly used prognostic markers in a hypothermia-treated cohort of cardiac arrest patients with prolonged coma. METHODS: Among 111 consecutive patients, 19 died, 58 recovered, and 34 were in coma 3 days after normothermia (4.5 days after cardiac arrest), defined as prolonged coma. All patients were monitored with continuous amplitude-integrated EEG and repeated samples of neuron-specific enolase (NSE) were collected. In patients with prolonged coma, somatosensory evoked potentials (SSEP) and brain MRI were performed. A postmortem brain investigation was undertaken in patients who died. RESULTS: Six of the 17 patients (35%) with NSE levels <33 µg/L at 48 hours regained the capacity to obey verbal commands. By contrast, all 17 patients with NSE levels >33 failed to recover consciousness. In the >33 NSE group, all 10 studied with MRI had extensive brain injury on diffusion-weighted images, 12/16 lacked cortical responses on SSEP, and all 6 who underwent autopsy had extensive severe histologic damage. NSE levels also correlated with EEG pattern, but less uniformly, since 11/17 with NSE <33 had an electrographic status epilepticus (ESE), only one of whom recovered. A continuous EEG pattern correlated to NSE <33 and awakening. CONCLUSIONS: NSE correlates well with other markers of ischemic brain injury. In patients with no other signs of brain injury, postanoxic ESE may explain a poor outcome.


Subject(s)
Coma/diagnosis , Heart Arrest/blood , Heart Arrest/diagnosis , Phosphopyruvate Hydratase/blood , Aged , Biomarkers/blood , Cardiopulmonary Resuscitation , Coma/blood , Female , Heart Arrest/therapy , Humans , Hypothermia, Induced , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies
7.
Interv Neuroradiol ; 15(4): 385-94, 2009 Dec.
Article in English | MEDLINE | ID: mdl-20465874

ABSTRACT

SUMMARY: Reduction of the cerebral perfusion pressure caused by vessel occlusion or stenosis is a cause of neurological symptoms and border-zone infarctions. The aim of this article is to describe perfusion patterns in hemodynamic stroke, to give a practical approach for the assessment of colour encoded CT- and MR-perfusion maps and to demonstrate the clinical use of comprehensive imaging in the workup of patients with hemodynamic stroke. Five patients with different duration cause and degree of hemodynamic stroke were selected. The patients shared the typical presentation with fluctuating and transient symptoms. All were examined by MR or CT angiography and MR or CT perfusion in the symptomatic phase. All patients were examined with diffusion weighted imaging. All five cases showed the altered perfusion patterns of hemodynamic insufficiency with a slight or marked increase in CBV in the supply area of the affected vessel and only slightly reduced or maintained CBF. The perfusion disturbances were most easily detected on the MTT maps. Border-zone infarctions were seen in all cases. The typical pattern for hemodynamic insufficiency is characterized by increased CBV, normal or decreased CBF and prolonged MTT in the affected areas. The increased CBV is the hallmark of stressed autoregulation. Reading the color-encoded perfusion maps enables a quick and robust assessment of the cerebral perfusion and its characteristic patterns. Internal border-zone infarctions can be regarded as a marker for hemodynamic insufficiency. Finding of the typical rosary-like pattern of DWI lesions should call for further work up.

SELECTION OF CITATIONS
SEARCH DETAIL
...