1.
Sensors (Basel) ; 23(2)2023 Jan 04.
Article in English | MEDLINE | ID: mdl-36679365

ABSTRACT

The article presents research on the performance of different distributed fibre optic sensing (DFOS) tools, including both layered cables and monolithic composite sensors. The main need for the presented research was related to the growing applications of the DFOS techniques for the measurements of cracked concrete structures. There are no clear guidelines on the required parameters of the DFOS tools, which, despite their different designs, are offered for the same purpose (strain sensing). The state-of-the-art review and previous experiences show noticeable differences in the quality of the results depending on the applied DFOS tool. The technical construction of selected solutions was described with its theoretical consequences, and then laboratory tests on full-size reinforced concrete beams were discussed. Beams equipped with embedded tools were investigated in four-point bending tests, causing the formation of multiple cracks in the tension zone along the beams' length. The results in the form of strain profiles registered by selected DFOS tools were analysed regarding the qualitative (crack detection) and quantitative (width estimation) crack assessment. The comparison between crack-induced strain profiles was based on a new parameter called crack shape coefficient CSC, which could be applied to assess the effectiveness of the particular DFOS tool in crack detection and analysis. It was one of the world's first research allowing for such direct comparison between the layered and monolithic sensing tools. The summary indicates practical guidelines referring to the preferable design of the tools best suitable for crack measurements, as well as the field proofs based on data from two concrete bridges in Germany.


Subject(s)
Fiber Optic Technology , Germany
2.
Sensors (Basel) ; 22(22)2022 Nov 11.
Article in English | MEDLINE | ID: mdl-36433309

ABSTRACT

The article presents research on the performance of composite and monolithic sensors for distributed fibre optic sensing (DFOS). The introduction summarises the design of the sensors and the theoretical justification for such an approach. Lessons learned during monitoring cracked concrete are summarised to highlight what features of the DFOS tools are the most favourable from the crack analysis point of view. Later, the results from full-size laboratory concrete specimens working in a cracked state were presented and discussed in reference to conventional layered sensing cables. The research aimed to compare monolithic sensors and layered cables embedded in the same reinforced concrete elements, which is the main novelty. The performance of each DFOS nondestructive tool was investigated in the close vicinity of the cracks-both the new ones, opening within the tension zone, and the existing ones, closing within the compression zone. The qualitative (detection) and quantitative (widths estimation) crack analyses were performed and discussed. Finally, the examples of actual applications within concrete structures, including bridges, are presented with some examples of in situ results.

3.
Sensors (Basel) ; 21(19)2021 Oct 03.
Article in English | MEDLINE | ID: mdl-34640927

ABSTRACT

Diagnostics and assessment of the structural performance of collectors and tunnels require multi-criteria as well as comprehensive analyses for improving the safety based on acquired measurement data. This paper presents the basic goals for a structural health monitoring system designed based on distributed fiber optic sensors (DFOS). The issue of selecting appropriate sensors enabling correct strain transfer is discussed hereafter, indicating both limitations of layered cables and advantages of sensors with monolithic cross-section design in terms of reliable measurements. The sensor's design determines the operation of the entire monitoring system and the usefulness of the acquired data for the engineering interpretation. The measurements and results obtained due to monolithic DFOS sensors are described hereafter on the example of real engineering structure-the Burakowski concrete collector in Warsaw during its strengthening with glass-fiber reinforced plastic (GRP) panels.


Subject(s)
Fiber Optic Technology , Sewage , Monitoring, Physiologic , Plastics
4.
Sensors (Basel) ; 21(17)2021 Sep 02.
Article in English | MEDLINE | ID: mdl-34502793

ABSTRACT

Due to the low costs of distributed optical fibre sensors (DFOS) and the possibility of their direct integration within layered composite members, DFOS technology has considerable potential in structural health monitoring of linear underground infrastructures. Often, it is challenging to truly simulate the actual ground conditions at all construction stages. Thus, reliable measurements are required to adjust the model and verify theoretical calculations. The article presents a new approach to monitor displacements and strains in Glass Fiber Reinforced Polymer (GFRP) collectors and pipelines using DFOS. The research verifies the effectiveness of the proposed monitoring solution for health monitoring of composite pipelines. Optical fibres were installed over the circumference of a composite tubular pipe, both on the internal and external surfaces, while loaded externally. Analysis of strain profiles allowed for calculating the actual displacements (shape) of the pipe within its cross-section plane using the Trapezoidal method. The accuracy of proposed approach was positively verified both with reference spot displacement transducer as well as numerical simulations using finite element method (FEM). DFOS could obtain a comprehensive view of structural deformations, including both strains and displacements under externally applied load. The knowledge gained during research will be ultimately used for renovating existing collectors.


Subject(s)
Fiber Optic Technology , Optical Fibers , Polymers , Transducers
5.
Sensors (Basel) ; 21(15)2021 Jul 27.
Article in English | MEDLINE | ID: mdl-34372325

ABSTRACT

Thanks to the dynamic development of advanced building technologies as well as the growing awareness, experience and responsibilities of engineers, structural health monitoring systems (SHM) are increasingly applied in civil engineering and geotechnical applications. This is also facilitated by the construction law and standard requirements, e.g., the observation method for geotechnical structures described in the Eurocode 7. Still, the most common approach is to apply spot sensors in selected points of the structure to validate theoretical models, numerical simulations and support technical assessments by involving statistic and approximation methods. The main limitation of spot sensing is the inability to detect localized damages such as cracks, fractures, sinkholes or shear planes. Thus, such analysis is subject to considerable uncertainty, especially within geotechnical structures, characterized by random mechanical parameters that change with location, but also over time. Another approach is based on distributed fibre optic sensors (DFOS), which are finding a growing acceptance in laboratory and field projects, overcoming limitations of conventional measurements. The design and applications of new DFOS dedicated for 3D displacement sensing are described hereafter in the article. The novelty of the presented solution lies in several features, including design, application, production technology and materials. This article is focused on the operational rules governing DFOS and proving their effectiveness in laboratory and geotechnical field applications.

6.
Sensors (Basel) ; 21(14)2021 Jul 08.
Article in English | MEDLINE | ID: mdl-34300420

ABSTRACT

Structural health monitoring (SHM) is a challenging task, especially in the context of ground and geotechnical structures. They are characterized by a set of random mechanical parameters, depending on the location but also changing with external conditions (such as humidity or temperature) over time. Theoretical predictions and results of numerical simulations are, therefore, considerably uncertain. On the other hand, measurements aimed at improving construction and operation of such structures are very often performed only in selected points, which significantly increases the risk of data misinterpretation. Reliable measurement data related to structural condition are of the great importance because they allow for improvement of work quality but also reduce construction time and, thereby, save money. That is why scientists and engineers are still searching for new measurement solutions to overcome existing limitations. The purpose of the study is to present the design and practical application of a new hydraulic sensor dedicated to vertical displacement sensing. The novelty of the presented solution lies in several features, including the possibility of performing automatic measurements and compensating the results due to temperature effects. The article describes the sensor's design, including the concept of a thermal compensation system and example results from laboratory tests, where the sensor's performance was investigated in a dual-zone thermal chamber. Finally, the sensor was installed within the field conditions under an embankment constructed above the improved substrate. Example results verified by reference distributed fiber optic technique are presented and discussed hereafter, raising high prospects in the context of possible structural health monitoring applications of the new solution.


Subject(s)
Fiber Optic Technology , Temperature