1.
Stud Health Technol Inform ; 272: 103-106, 2020 Jun 26.
Article in English | MEDLINE | ID: mdl-32604611

ABSTRACT

Ballistocardiography is a method to gain detailed information about body movements imparted by the ballistic forces associated with cardiac contraction. We measured using different setups and sensor positions to gain information of a reference signal of healthy adults. We used two resting state recordings and two recordings under physical stress (ergometer and treadmill) with stepwise increasing load. Data was gathered from 34 subjects, which results in 72 data sets, overall, more than 18h of signal data. With these data we have created a first database for BCG reference. We started data analysis and created a first naive data representation prototype. Using this naive attempt, we created a user interface for the intuitive representation of live data as well as retrospective data.


Subject(s)
Ballistocardiography , Movement , Retrospective Studies
2.
Stud Health Technol Inform ; 270: 808-812, 2020 Jun 16.
Article in English | MEDLINE | ID: mdl-32570494

ABSTRACT

Ballistocardiography (BCG) has gained more attention due to the fundamental goal of medical intervention in diagnostics and follow-up. BCG is particularly suitable for the study of heart failure, which a recent study has shown. The results of this working group shall be validated and reproduced with another study trial. Therefore, acceleration sensor prototypes will be placed on various parts of the patient's body and be connected to a computer unit, which allows a high data quality and high signal resolution. A temporal shift of only 20 ns ensures real-time measurement of BCG parameters. The reference measurement will be done with a 12-channel ECG. The study will include patients with heart failure. All conducted tests take place as part of the diagnostic-therapeutic routine. The only change in the procedure concerns the additional equipment with the measuring sensors. The results will be the validation of the data from the other working group, as well as the information about the choice of sensors and clock frequency, the measuring points and the needed features for early detection of heart failure in BCG signals.


Subject(s)
Ballistocardiography , Heart Failure , Acceleration , Electrocardiography , Heart Rate , Humans , Signal Processing, Computer-Assisted