Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
J Emerg Med ; 61(3): 314-319, 2021 09.
Article in English | MEDLINE | ID: mdl-33836911

ABSTRACT

BACKGROUND: Thiamine deficiency is an uncommon cause of severe illness in the United States that can lead to significant morbidity because of high-output cardiac failure, peripheral neuropathy, and permanent neurologic impairment. We report the case of a middle-aged woman with extreme malnutrition caused by complications of Roux-en-Y gastric bypass (RYGB) surgery who presented with signs and symptoms of severe thiamine deficiency and septic shock. CASE REPORT: A 43-year-old woman who had undergone RYGB surgery and who had multiple complications presented to the emergency department with agitation, confusion, and lethargy. The physical examination revealed an obtunded woman appearing much older than her reported age with significant peripheral edema. She was hypoxemic, hypotensive, and febrile. The initial laboratory analysis revealed a serum lactate level above the measurable limit, a normal thyroid-stimulating hormone, and elevated levels of troponin and brain natriuretic peptide. A transthoracic echocardiogram showed high-output heart failure. The patient's family later revealed that for the past year her diet had consisted almost exclusively of frozen blended lattes. High doses of thiamine and folate were started. Her shock, hyperlactatemia, and respiratory failure resolved by hospital day 3 and her encephalopathy resolved soon thereafter. Why Should an Emergency Physician be Aware of This?: Thiamine deficiency is a rare but reversible cause of shock, heart failure, and encephalopathy. Identifying patients who are at risk for severe nutritional deficiencies may aid in more rapid treatment with relatively benign medications with little downside, in this case high-dose vitamin B1, and ultimately improve patient-oriented outcomes such as mortality, morbidity, and hospital length of stay.


Subject(s)
Beriberi , Brain Diseases , Malnutrition , Thiamine Deficiency , Wernicke Encephalopathy , Adult , Beriberi/complications , Beriberi/diagnosis , Female , Humans , Malnutrition/complications , Middle Aged , Thiamine/therapeutic use , Thiamine Deficiency/complications
2.
J Neurosurg ; 126(5): 1472-1478, 2017 May.
Article in English | MEDLINE | ID: mdl-27447440

ABSTRACT

The authors report an unusual case of a widely metastatic glioblastoma. DNA copy number microarray profile of the resected specimen revealed complex rearrangements found throughout chromosome 6, a phenomenon known as chromothripsis. Such chromothripsis pattern was not observed in 50 nonmetastatic glioblastoma specimens analyzed. Analysis of the 1000+ gliomas profiled by The Cancer Genome Atlas (TCGA) data set revealed one case of chromosome 6 chromothripsis resembling the case described here. This TCGA patient died within 6 months of undergoing tumor resection. Implications of these findings are reviewed in the context of the current literature.


Subject(s)
Brain Neoplasms/genetics , Brain Neoplasms/pathology , Chromosomes, Human, Pair 6/genetics , Chromothripsis , Glioblastoma/genetics , Glioblastoma/secondary , Glioblastoma/diagnostic imaging , Humans , Male , Young Adult
3.
Acta Neurochir (Wien) ; 158(9): 1655-60, 2016 09.
Article in English | MEDLINE | ID: mdl-27395018

ABSTRACT

Self-injection of household cleaning detergents (more specifically, commercial toilet bowl cleaner) into the reservoir of a ventriculoperitoneal shunt (VPS) has never been reported in the neurosurgical literature. A right-handed 41-year-old female with a past medical history significant for bipolar depression (with multiple prior hospital admissions for suicide attempts) and pseudotumor cerebri (status-post VPS placement from a right frontal approach) successfully injected ∼5 ml of toilet bowl cleaner into her ventricular shunt reservoir during a suicide attempt. She was found unresponsive by a family member 48 h after this event and presented to our hospital in moribund neurological condition (bilaterally fixed and dilated pupils with decerebrate posturing). Head computed tomography (CT) demonstrated marked ventriculomegaly. She was taken emergently to the operating room for placement of a left frontal ventriculostomy. Cerebrospinal fluid (CSF) sampled intraoperatively showed numerous Gram-positive cocci (later determined to be Staphylococcus epidermidis). For this reason, her right-sided shunt system was also removed in its entirety. She was treated with broad-spectrum intravenous and intraventricular antibiotics for her bacterial ventriculitis and her CSF was aggressively drained to treat her hydrocephalus. Once her infection had resolved, the shunt was replaced (using a right parietal approach) and she went on to make an excellent neurological recovery. Here, the authors present the case of a patient who self-injected household cleaning detergents into her VPS reservoir-and, likely, the ventricular system-during a suicide attempt and subsequently developed hydrocephalus and ventriculitis. Following this infrequent clinical scenario, consideration should be given to temporary ventriculostomy placement and shunt removal. Moreover, in patients with a known history of psychiatric co-morbidities-and particularly those patients with prior suicide attempts-the neurosurgeon should give serious consideration to placing the shunt system in an anatomical region which is difficult for the patient to self-access based upon their handedness.


Subject(s)
Cerebral Ventricles/drug effects , Detergents/poisoning , Suicide, Attempted , Ventriculoperitoneal Shunt , Adult , Cerebral Ventricles/surgery , Detergents/administration & dosage , Female , Humans , Hydrocephalus/surgery , Injections
5.
Expert Rev Neurother ; 15(8): 919-33, 2015.
Article in English | MEDLINE | ID: mdl-26200128

ABSTRACT

Intracerebral hemorrhages (ICH) cause high levels of morbidity and mortality. Secondary neuronal injury from perihematomal edema is thought to contribute to poor outcomes. Surgical evacuation of ICH is a theoretically promising approach, yet clinical data on the efficacy of standard craniotomy approaches is limited. Recent exploration of minimally invasive techniques for ICH removal includes stereotactic surgery combined with intra-clot thrombolysis, as well as endoscopic hematoma evacuation. Ongoing trials have demonstrated the safety of such minimally invasive approaches, and pending efficacy data from these studies is likely to change the standard management of ICH.


Subject(s)
Cerebral Hemorrhage/therapy , Minimally Invasive Surgical Procedures/methods , Humans , Treatment Outcome
6.
Radiology ; 271(1): 282-90, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24475801

ABSTRACT

PURPOSE: To test the hypothesis that type II endoleak cavity volume (ECV) and endoleak cavity diameter (ECD) measurements are accurate indicators of aneurysm sac volume (ASV) enlargement in patients who undergo endovascular aneurysm repair (EVAR) in the abdominal aorta. MATERIALS AND METHODS: The institutional review board approved and waived the need to obtain patient consent for this HIPAA-compliant retrospective study. In 72 patients who underwent EVAR, 160 computed tomographic (CT) angiography studies revealed type II endoleaks. Corresponding to these 160 CT angiography studies, 113 CT follow-up studies (in 52 patients) were available and were included in the analysis. ECV measurements were obtained by two observers in consensus by using arterial enhanced phase (ECVAEP) and 70-second delayed enhanced phase (ECVDEP) CT images. The ECVDEP was also normalized as the ECV/ASV ratio. Maximum (ECDM) and transverse (ECDT) ECDs were determined from delayed enhanced phase images. The outcome was determined as interval increase (>2%) in ASV versus stable or decreasing (≤2%) ASV. Receiver operating characteristic (ROC) analysis was used to compare the accuracy of type II ECV and ECD measurements in indicating interval increase in ASV. RESULTS: In 56 (49.5%) of 113 CT studies in type II endoleaks, there was an interval increase in ASV. The accuracies of ECVDEP (area under the ROC curve [AUC], 0.85) and normalized ECVDEP (AUC, 0.86) were superior to the accuracies of ECDM (AUC, 0.73), ECDT (AUC, 0.73), and ECVAEP (AUC, 0.66). At ROC curve analysis, the sensitivity, specificity, and positive and negative predictive values for type II endoleak cavities with an ECVDEP of less than 0.5 mL for showing no future sac volume enlargement were 33% (19 of 57), 100% (56 of 56), 100% (19 of 19), and 60% (56 of 94), respectively. CONCLUSION: With use of the delayed enhanced phase of CT angiography, ECV measurement is an accurate indicator of aneurysm sac enlargement.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Endoleak/diagnostic imaging , Tomography, X-Ray Computed , Aged , Aortic Aneurysm, Abdominal/pathology , Blood Vessel Prosthesis Implantation , Endoleak/classification , Female , Humans , Imaging, Three-Dimensional , Male , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Sensitivity and Specificity , Treatment Outcome
7.
J Comput Assist Tomogr ; 37(2): 297-300, 2013.
Article in English | MEDLINE | ID: mdl-23493223

ABSTRACT

Intraluminal layering of iodinated contrast on a single axial computed tomography image is described as a possible sign of slow arterial flow and is quantified using a new region of interest-based metric, that is, gravitational gradient. The metric was measured in 4 patients who demonstrated this phenomenon and in the aorta of 10 patients with no clinical sign suggestive of slow flow. Future studies are needed to validate the relationship between gravitational gradient, slow flow, and patient outcome.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Contrast Media/administration & dosage , Iopamidol/administration & dosage , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Blood Flow Velocity , Gravitation , Humans , Male , Middle Aged
8.
Int J Cardiovasc Imaging ; 28(4): 965-73, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21670986

ABSTRACT

To retrospectively evaluate prognostic accuracy of subjective assessment of right ventricle (RV) enlargement on CT pulmonary angiography (CTPA) images in comparison with objective measures of RV enlargement in patients with acute pulmonary embolism (PE). For 200 consecutive patients with acute PE, two readers blinded to patient outcomes subjectively determined whether the maximum RV diameter was greater than that of the left ventricle (LV) using axial CTPA images. For the objective measurements, RV/LV diameter ratios were calculated using axial images and 4-chamber reformatted images. For all assessments, sensitivities and specificities for predicting PE-related death within 30-days and a composite outcome including PE-related death or the need for intensive therapies were compared. The agreement between two readers was 91.5% (kappa = 0.83) and all other assessments had pair-wise agreement over 75% (kappa = 0.53-0.72). There was no significant difference in sensitivity between the subjective and objective methods for predicting both outcomes. The specificity for subjective RV enlargement (55.4-67.7%) was significantly higher than objective measures (45.8-53.1%), except for the 4-chamber views where, for one reader, the specificity of the subjective evaluation was higher but did not reach statistical significance. Complex measurements of RV/LV diameter ratios may not be needed to maximize the prognostic value from CTPA. The radiologist who interprets the CTPA images should report RV enlargement when the RV diameter subjectively appears larger than the LV.


Subject(s)
Hypertrophy, Right Ventricular/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Pulmonary Embolism/diagnostic imaging , Tomography, X-Ray Computed , Boston , Humans , Hypertrophy, Right Ventricular/etiology , Hypertrophy, Right Ventricular/mortality , Observer Variation , Predictive Value of Tests , Prognosis , Pulmonary Embolism/complications , Pulmonary Embolism/mortality , Reproducibility of Results , Retrospective Studies , Risk Assessment , Risk Factors , Sensitivity and Specificity , Time Factors
9.
Int J Cardiovasc Imaging ; 28(2): 381-8, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21336552

ABSTRACT

The purpose of this study was to estimate dose reduction after implementation of asymmetrical cone beam processing using exposure differences measured in a water phantom and a small cohort of clinical coronary CTA patients. Two separate 320 × 0.5 mm detector row scans of a water phantom used identical cardiac acquisition parameters before and after software modifications from symmetric to asymmetric cone beam acquisition and processing. Exposure was measured at the phantom surface with Optically Stimulated Luminescence (OSL) dosimeters at 12 equally spaced angular locations. Mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at the center plus four peripheral locations in the water phantom. To assess image quality, mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at five points within the water phantom. Retrospective evaluation of 64 patients (37 symmetric; 27 asymmetric acquisition) included clinical data, scanning parameters, quantitative plus qualitative image assessment, and estimated radiation dose. In the water phantom, the asymmetric cone beam processing reduces exposure by approximately 20% with no change in image quality. The clinical coronary CTA patient groups had comparable demographics. The estimated dose reduction after implementation of the asymmetric approach was roughly 24% with no significant difference between the symmetric and asymmetric approach with respect to objective measures of image quality or subjective assessment using a four point scale. When compared to a symmetric approach, the decreased exposure, subsequent lower patient radiation dose, and similar image quality from asymmetric cone beam processing supports its routine clinical use.


Subject(s)
Cone-Beam Computed Tomography , Coronary Angiography/methods , Coronary Disease/diagnostic imaging , Radiation Dosage , Adult , Aged , Algorithms , Boston , Cone-Beam Computed Tomography/instrumentation , Coronary Angiography/instrumentation , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Predictive Value of Tests , Radiation Monitoring/methods , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results , Retrospective Studies
10.
J Thorac Imaging ; 27(5): 331-6, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22139353

ABSTRACT

PURPOSE: To evaluate variability in right ventricular-to-left ventricular (RV/LV) diameter ratios introduced by differences in measurement methods and the subsequent influence on the accuracy of predicting outcomes for patients with acute pulmonary embolism (PE). MATERIALS AND METHODS: For 200 consecutive computed tomography pulmonary angiograms positive for acute PE, RV/LV diameter ratios were retrospectively measured using 3 different 4-chamber reformations and from axial images alone. The first 4-chamber reformation method (4ch-1) was a single oblique technique using LV morphology landmarks; the other 2 methods (4ch-2 and 4ch-3) were double oblique techniques that created an intermediate short-axis image to identify the maximum RV diameter but with different approaches to reach short-axis images. Interobserver variability was measured using 30 cases. Receiver-operating characteristic analysis compared the accuracy of predicting outcomes among the 4 measurements for PE-related death, and for death or the need for intensive therapies (composite outcome). RESULTS: The difference in median RV/LV diameter ratios was insignificant among 4ch-2 (1.01), 4ch-3 (1.02), and axial (1.03) datasets, whereas that from 4ch-1 (0.93) was significantly lower (P<0.001). Correlation between observers was excellent for all 4 datasets (r=0.881 to 0.925). Compared with 4ch-1, the other 3 datasets equally achieved higher accuracy in predicting PE-related 30-day mortality (area under curve: 0.55 vs. 0.69 to 0.73, P=0.007 to 0.019) and a composite outcome (area under curve: 0.65 vs. 0.77 to 0.78, P=0.003 to 0.010). CONCLUSIONS: Double oblique 4-chamber reformation methods that use intermediate short-axis images to optimize RV size predict outcomes better in patients with acute PE than do single oblique methods using only LV landmarks; however, their accuracy is not superior to that from measurements based on axial images.


Subject(s)
Angiography/methods , Heart Ventricles/anatomy & histology , Pulmonary Embolism/diagnostic imaging , Acute Disease , Adult , Aged , Aged, 80 and over , Female , Heart Ventricles/diagnostic imaging , Humans , Lung/diagnostic imaging , Male , Middle Aged , Predictive Value of Tests , Prognosis , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Young Adult
11.
Eplasty ; 11: e51, 2011.
Article in English | MEDLINE | ID: mdl-22184509

ABSTRACT

OBJECTIVE: Face transplantation replaces substantial defects with anatomically identical donor tissues; preoperative vascular assessment relies on noninvasive imaging to separate and characterize the external carotid vessels and branches. The objective is to describe and illustrate vascular considerations for face transplantation candidates. METHODS: Novel noninvasive imaging using computed tomography and magnetic resonance imaging over 3 spatial dimensions plus time was developed and tested in 4 face transplant candidates. Precontrast images assessed bones and underlying metal. Contrast media was used to delineate and separate arteries from veins. For computed tomography, acquisition over multiple time points enabled the computation of tissue perfusion metrics. Time-resolved magnetic resonance angiography was performed to separate arterial and venous phases. RESULTS: The range of circulation times for the external carotid system was 6 to 14 seconds from arterial blush to loss of venous enhancement. Precontrast imaging provided a roadmap of bones and metal. Among the 4 patients, 3 had surgical clips, metal implants, or both within 1 cm of major vessels considered for surgery. Contrast-enhanced wide area detector computed tomographic data acquired in the axial mode separated these structures and provided arterial and venous images for planning the surgical anastomoses. Magnetic resonance imaging was able to distinguish between the large vessels from the external carotid systems. CONCLUSIONS: Vascular imaging maps are challenging in face transplantation because of the rapid circulation times and artifact from the initial injury, prior reconstructive attempts, or both. Nevertheless, face transplant candidates require high spatial and temporal resolution vascular imaging to determine those vessels appropriate for surgical anastomoses.

12.
Plast Reconstr Surg ; 128(4): 883-891, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21921764

ABSTRACT

BACKGROUND: Facial allotransplantation requires a detailed arterial and venous assessment for surgical planning. Target vessels are often depleted by multiple reconstructive attempts or the severe facial injury itself. The purpose of this study was to retrospectively compare the diagnostic performance of computed tomography and magnetic resonance angiography in the preoperative assessment. METHODS: Four-dimensional (three spatial planes plus time) computed tomographic and magnetic resonance images including 126 potential vessels (76 arteries and 50 veins) from five candidates were analyzed independently by two radiologists using a four-point image quality scale. Computed tomographic versus magnetic resonance image quality was compared directly, using a computed tomographic angiography consensus read as reference standard. Vessels with metal artifact on magnetic resonance imaging, computed tomography, or both underwent separate analyses to determine the impact of metal implants on image quality. RESULTS: Considering all 126 vessels, the mean computed tomographic image quality was superior to that of magnetic resonance angiography. When considering individual vessels, all except for major neck vessels were better visualized by computed tomography. Images of 26 vessels were degraded by metal artifact; magnetic resonance image quality was inferior for those vessels. Considering images of major vessels with no metal artifact, there was no significant mean image quality difference between computed tomography and magnetic resonance imaging. CONCLUSIONS: Computed tomographic angiography should be used as the first-choice modality for preoperative imaging of facial transplant patients because, when compared with magnetic resonance imaging, the visualization of small vessels is far superior and images have fewer artifacts. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, II.


Subject(s)
Face/blood supply , Four-Dimensional Computed Tomography/methods , Magnetic Resonance Angiography/methods , Plastic Surgery Procedures/methods , Adult , Face/surgery , Female , Humans , Male , Observer Variation , Preoperative Care/methods , Retrospective Studies , Sampling Studies , Sensitivity and Specificity , Statistics, Nonparametric , Surgical Flaps/blood supply , Transplantation, Homologous
13.
AJR Am J Roentgenol ; 197(4): 844-50, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21940571

ABSTRACT

OBJECTIVE: The objective of our study was to evaluate the difference in coronary enhancement provided by 60 versus 80 mL of contrast medium (370 mg I/mL) for prospectively ECG-gated single-heartbeat axial 320-MDCT. MATERIALS AND METHODS: We retrospectively evaluated 108 consecutive 320-MDCT angiography studies. Group 1 (n = 36) received 60 mL of an iodinated contrast medium and group 2 (n = 72), 80 mL. All patients were imaged with a standardized protocol: iopamidol 370 followed by 40 mL of saline, both administered at a rate of 6 mL/s. Two imagers subjectively assessed image quality throughout the coronary arteries. Region-of-interest attenuation (HU) measurements were performed in the aorta plus the proximal and distal coronary arteries. RESULTS: Subjective analysis of all coronary segments showed slightly better image quality for group 2. Patients in group 1 had significantly (p < 0.05) lower mean attenuation values for the individual coronary vessels. Nevertheless, 96.7% of all coronary segments in the group 1 patients had an attenuation of greater than 300 HU; when analysis was limited to group 1 patients with a body mass index of greater than 30, 92.8% of the segments were more than 300 HU, and all segments measured more than 250 HU. CONCLUSION: An injection protocol based on 60 mL of iopamidol (370 mg I/mL) for prospectively ECG-gated wide-area detector single-heartbeat coronary CT angiography (CTA) has less coronary enhancement than a protocol based on 80 mL. However, using 60 mL, more than 96% of coronary segments had sufficient enhancement (i.e., > 300 HU), supporting the general use of 60-mL protocols for clinical wide-area detector coronary CTA.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Contrast Media/administration & dosage , Coronary Angiography/methods , Coronary Disease/diagnostic imaging , Iopamidol/administration & dosage , Tomography, X-Ray Computed/methods , Chi-Square Distribution , Female , Humans , Linear Models , Male , Middle Aged , Retrospective Studies , Statistics, Nonparametric
14.
J Comput Assist Tomogr ; 34(5): 766-9, 2010.
Article in English | MEDLINE | ID: mdl-20861783

ABSTRACT

We report initial surgical planning computed tomographic protocols for composite tissue allotransplantation of the face. This complex procedure replaces missing facial structures with anatomically identical tissues, restoring form and function. Achieved results are superior to those accomplished with conventional techniques. As a growing number of patients/recipients have undergone multiple reconstructions, vascular imaging plays an increasingly critical role in surgical planning and successful execution of the operation.


Subject(s)
Facial Injuries/surgery , Facial Transplantation , Tomography, X-Ray Computed/methods , Wounds, Gunshot/surgery , Adult , Facial Injuries/etiology , Humans , Imaging, Three-Dimensional , Male , Patient Care Planning , Radiation Dosage , Transplantation, Homologous
SELECTION OF CITATIONS
SEARCH DETAIL
...