Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Pharm Sci ; 197: 106769, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38631463

ABSTRACT

Pharmaceutical residues are widely detected in aquatic environment worldwide mainly arising from human excretions in sewage systems. Presently, publicly available, high quality environmental risk assessment (ERA) data for pharmaceuticals are limited. However, databases like the Swedish Fass offer valuable resources aiding healthcare professionals and environmental scientists in identifying substances of significant concern. In this review, we provide a concise overview of the regulatory ERA process for medicinal products intended for human use. We explore its key assumptions and uncertainties using a subset of 37 pharmaceuticals. First, we compare the consistency of their predicted no-effect concentrations reported in the Fass database with those by marketing authorisation holders. Second, we compare the predicted environmental concentrations (PEC) calculated based on sales data between European and national drug consumption statistics as well as with measured environmental concentrations (MEC), to demonstrate their impact on the regional risk quotients. Finally, we briefly discuss the prevailing uncertainties and challenges of current ecotoxicity testing, especially outcomes of chronic and nonlethal effects.


Subject(s)
Water Pollutants, Chemical , Risk Assessment/methods , Humans , Uncertainty , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/toxicity , Pharmaceutical Preparations , Animals , Environmental Monitoring/methods , Databases, Factual
2.
Analyst ; 142(14): 2552-2557, 2017 Jul 10.
Article in English | MEDLINE | ID: mdl-28617495

ABSTRACT

A micropillar array electrospray ionization (µPESI) platform fabricated from thiol-enes with 56 individual polyethylene glycol coated µPESI chips for bioanalytical mass spectrometry is introduced. Bioanalysis capability is shown by measurement of a protein, a protein digest and a cell lysate sample. The thiol-ene polyethylene glycol (PEG) coated µPESI chip allows the use of a wide range of aqueous-organic solvent compositions and provides a detection limit at 60 zeptomole level (6 × 10-20 mol) for a peptide standard.

3.
Biomicrofluidics ; 11(3): 034118, 2017 May.
Article in English | MEDLINE | ID: mdl-28652888

ABSTRACT

This work describes the fabrication of concave micromirrors to improve the sensitivity of fluorescence imaging, for instance, in single cell analysis. A new approach to fabrication of tunable round (concave) cross-sectional shaped microchannels out of the inorganic-organic hybrid polymer, Ormocomp®, via single step optical lithography was developed and validated. The concave micromirrors were implemented by depositing and patterning thin films of aluminum on top of the concave microchannels. The round cross-sectional shape was due to residual layer formation, which is inherent to Ormocomp® upon UV exposure in the proximity mode. We show that it is possible to control the residual layer thickness and thus the curved shape of the microchannel cross-sectional profile and eventually the focal length of the micromirror, by simply adjusting the UV exposure dose and the distance of the proximity gap (to the photomask). In general, an increase in the exposure dose or in the distance of the proximity gap results in a thicker residual layer and thus an increase in the radius of the microchannel curvature. Under constant exposure conditions, the radius of curvature is almost linearly dependent on the microchannel aspect ratio, i.e., the width (here, 20-200 µm) and the depth (here, 15-45 µm). Depending on the focal length, up to 8-fold signal enhancement over uncoated, round Ormocomp® microchannels was achieved in single cell imaging with the help of the converging micromirrors in an epifluorescence microscopy configuration.

SELECTION OF CITATIONS
SEARCH DETAIL
...