Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Indian J Ophthalmol ; 60(6): 541-3, 2012.
Article in English | MEDLINE | ID: mdl-23202394

ABSTRACT

AIMS: To create a normative data for lea grating (LG) in the Indian population and to compare LG with Cardiff Acuity Card (CAC). SETTINGS AND DESIGN: Normative Data was acquired from normal children between 6 months-3 years coming to the 'Immunisation Clinic' and 'Well-Baby Clinic' at a Civil Hospital. To compare LG with CAC, normal and amblyopic children between 6 months-3 years were evaluated, MATERIALS AND METHODS: Monocular and binocular visual acuity (VA) was measured using LG and then CAC. VA and time taken to perform the test were compared. STATISTICAL ANALYSIS USED: Pearson's Correlation Coefficient to compare VA and Student paired t-test (significance P<0.005) to compare time. RESULTS: Two standard deviations of VA of 100 normal children overlapped with that published by Lea. Of the 30 amblyopic children aged 18.32 ± 10.5 months (2-36), 18 were females. VA was 0.95 ± 0.3 logMAR (0.7-1.2) and 1.0 ± 0.6 logMAR (0.5-2.1) binocularly and 1.32 ± 0.08 logMAR (0.2-0.6) and 1.15 ± 0.15 logMAR (0.88-1.48) monocularly on CAC and LG respectively. Pearson's correlation coefficient was 0.98 and 0.63 for binocular and monocular assessment respectively. Time taken to perform LG monocularly and binocularly was significantly less (P<0.001) than CAC. CONCLUSION: Normative data acquired in Indian pre-verbal children is similar to that published by Lea. Though VA by CAC is better than LG, the two tests are comparable.


Subject(s)
Amblyopia/diagnosis , Vision Tests/instrumentation , Vision, Binocular/physiology , Vision, Monocular/physiology , Visual Acuity/physiology , Child, Preschool , Female , Humans , Infant , Male
3.
Anal Bioanal Chem ; 378(6): 1666-9, 2004 Mar.
Article in English | MEDLINE | ID: mdl-15214433

ABSTRACT

Tetraazacyclotetradecane, tetratosyltetraaza 12C4, and tritosyltriaza 9C3 have been explored as electroactive materials for preparing coated wire ion-selective electrodes (CWISEs) for Cr(III) ions. The best performance was observed for the membrane comprising electroactive material (tetratosyltetraaza 12C4), plasticizer (dibutyl phthalate), and poly(vinyl chloride) in the optimum ratio 5:60:35 (w/w). Linear Nernstian response for this electrode was obtained over the total Cr(III) concentration range of 1 x 10(-1) to 1 x 10(-7) M in 0.05 M NH4NO3 medium, with a slope of 20 +/- 1 mV per decade change. The working pH range of the electrode was 1.8-5.5. Selectivity coefficients of some mono, divalent, and trivalent metal ions were determined. Analyses of electroplating bath solutions, chromating, and effluent samples have been carried out using this CWISE and the results are found to be comparable with those obtained by using conventional methods or by AAS.

SELECTION OF CITATIONS
SEARCH DETAIL
...