Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Eur J Radiol ; 142: 109859, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34284232

ABSTRACT

Portal vein thrombosis is a pathological condition characterized by the lumen occlusion of the portal vein and its intrahepatic branches, commonly associated to chronic liver diseases. Portal vein thrombosis is often asymptomatic and discovered as an incidental finding in the follow-up of chronic hepatopathy. Imaging plays a pivotal role in the detection and characterization of portal vein thrombosis in patients with hepatocellular carcinoma. Ultrasound and Color-Doppler ultrasound are usually the first-line imaging modalities for its detection, but they have limits related to operator-experience, patient size, meteorism and the restrained field-of view. Unenhanced cross-sectional imaging doesn't provide specific signs of portal vein thrombosis except under certain specific circumstances. Conventional contrast-enhanced imaging can depict portal vein thrombosis as an endoluminal filling defect best detected in venous phase and can differentiate between non-neoplastic and neoplastic thrombus based on the contrast enhanced uptake, but not always rule-out the malignant nature. Functional and quantitative imaging techniques and software seem to be more accurate. The purpose of this work is to provide the reader with an accurate overview focused on the main imaging features of portal vein thrombosis.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Thrombosis , Venous Thrombosis , Carcinoma, Hepatocellular/complications , Carcinoma, Hepatocellular/diagnostic imaging , Humans , Liver Neoplasms/complications , Liver Neoplasms/diagnostic imaging , Portal Vein/diagnostic imaging , Venous Thrombosis/diagnostic imaging
2.
Clin Radiol ; 72(1): 33-40, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27729105

ABSTRACT

AIM: To evaluate the precision of the centrality index (CI) measurement on three-dimensional (3D) volume rendering technique (VRT) images in patients with renal masses, compared to its standard measurement on axial images. MATERIALS AND METHODS: Sixty-five patients with renal lesions underwent contrast-enhanced multidetector (MD) computed tomography (CT) for preoperative imaging. Two readers calculated the CI on two-dimensional axial images and on VRT images, measuring it in the plane that the tumour and centre of the kidney were lying in. Correlation and agreement of interobserver measurements and inter-method results were calculated using intraclass correlation (ICC) coefficients and the Bland-Altman method. Time saving was also calculated. RESULTS: The correlation coefficients were r=0.99 (p<0.05) and r=0.99 (p<0.05) for both the CI on axial and VRT images, with an ICC of 0.99, and 0.99, respectively. Correlation between the two methods of measuring the CI on VRT and axial CT images was r=0.99 (p<0.05). The two methods showed a mean difference of -0.03 (SD 0.13). Mean time saving per each examination with VRT was 45.5%. CONCLUSIONS: The present study showed that VRT and axial images produce almost identical values of CI, with the advantages of greater ease of execution and a time saving of almost 50% for 3D VRT images. In addition, VRT provides an integrated perspective that can better assist surgeons in clinical decision making and in operative planning, suggesting this technique as a possible standard method for CI measurement.


Subject(s)
Imaging, Three-Dimensional/methods , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/surgery , Multidetector Computed Tomography/methods , Patient Selection , Preoperative Care/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Observer Variation , Prognosis , Radiographic Image Enhancement/methods , Reproducibility of Results , Retrospective Studies , Risk Assessment , Sensitivity and Specificity , Severity of Illness Index
3.
Eur Rev Med Pharmacol Sci ; 20(22): 4635-4641, 2016 11.
Article in English | MEDLINE | ID: mdl-27906441

ABSTRACT

OBJECTIVE: Reconstruction following mastectomy offers women an opportunity to mollify some of the emotional and aesthetic effects of this devastating disease. PATIENTS AND METHODS: The authors reviewed the files of 83 patients who underwent immediate postmastectomy reconstruction with tissue expander between January of 2003 and June of 2012 at our hospital. The patients were divided into two groups: Group A (study group) included 30 patients with previous quadrantectomy and radiotherapy who underwent salvage mastectomy after local recurrence; Group B (control group) included 53 patients submitted to primary radical mastectomy. We submitted Breast-Q reconstruction post-operative module to all of our patients. RESULTS: The median follow-up time for the whole group was 36 months (range = 12-144 months). Between group A and group B, there were no significant differences. In the group A, the median time from RT to reconstruction was 24 months (range = 9-192 months). The overall rate of complications was not similar between the two groups (66.6% vs. 58.5%; p = NS). However, the  major complications occurred mostly in the irradiated group, showing a trend of statistical significance (53.3% vs. 32.0%; p = 0.07). In this group, the occurrence of major complications was not different according to time from RT to reconstruction (p = 0.313). In particularly, patients from the irradiated group (group A) had a significantly higher risk of grade III-IV capsular contracture (relative risk 3.75, p = 0.02) and autologous salvage reconstruction (relative risk 10.4, p = 0.02). CONCLUSIONS: The results of this study prove that heterologous reconstruction is still possible following salvage mastectomy in previously irradiated patients.


Subject(s)
Breast Neoplasms/psychology , Breast Neoplasms/surgery , Personal Satisfaction , Female , Humans , Mammaplasty , Mastectomy , Neoplasm Recurrence, Local/surgery , Retrospective Studies , Time Factors , Treatment Outcome
4.
Clin Radiol ; 71(9): 938.e1-9, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27241866

ABSTRACT

AIM: To investigate the diagnostic accuracy of dual-energy multidetector computed tomography (MDCT) with iodine quantification compared to conventional enhancement measurements in distinguishing bland from neoplastic portal vein thrombosis in patients with hepatocellular carcinoma. MATERIAL AND METHODS: Thirty-four patients (26 men, eight women; mean age, 62 years) with hepatocellular carcinoma and portal vein thrombosis underwent contrast-enhanced dual-energy MDCT during the late hepatic arterial phase for the assessment of portal thrombosis (bland, n=21; neoplastic, n=13). Datasets were analysed separately by two different readers. Interobserver correlation and variability were calculated and compared with the Bland-Altman method. Diagnostic accuracy of conventional enhancement measurements and iodine quantification was calculated by setting either histopathology (n=7) or a reference standard based on MDCT imaging criteria and thrombus evolutionary characteristics compared to a previous MDCT examination (n=27). For iodine quantification threshold determination receiver operating characteristic (ROC) curves were drawn. p-Values <0.05 were considered significant. RESULTS: For conventional enhancement measurements and iodine quantification interobserver correlation was 98% and 96%. Enhancement measurement resulted in a sensitivity of 92.3%, specificity of 85.7%, positive predictive value (PPV) of 80%, and negative predictive value (NPV) of 94.7%. An iodine concentration of 0.9 mg/ml optimised discrimination between neoplastic and bland thrombi (area under the ROC [AUC] 0.993) resulting in a sensitivity of 100%, specificity of 95.2%, PPV of 92.9%, and NPV of 100%. The overall diagnostic accuracy of iodine quantification (97%) was significantly better than conventional enhancement measurements (88.2%; p<0.001). CONCLUSION: Compared to conventional enhancement measurements, iodine quantification improves the characterisation of portal vein thrombi during the late hepatic arterial phase in patients with hepatocellular carcinoma.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Multidetector Computed Tomography/methods , Portal Vein/diagnostic imaging , Radiography, Dual-Energy Scanned Projection/methods , Venous Thrombosis/diagnostic imaging , Aged , Carcinoma, Hepatocellular/complications , Contrast Media , Diagnosis, Differential , Female , Humans , Iodine , Liver Neoplasms/complications , Male , Middle Aged , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity , Venous Thrombosis/etiology
5.
Clin Oncol (R Coll Radiol) ; 26(11): 677-83, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25175041

ABSTRACT

AIMS: To investigate the role of surgical clips in defining the clinical target volume (CTV) for three-dimensional conformal external beam radiotherapy-partial breast irradiation (3D-CRT-PBI) using preoperative computed tomography scans. MATERIALS AND METHODS: A group of patients with early breast cancer underwent conservative surgery with placement of surgical titanium clips (at least three clips required). All patients had a treatment planning computed tomography simulation before (CT1) and after surgery (CT2). The two sets of images were co-registered with a match point registration. The relationship between the clips-based CTV for PBI delineated on CT2 and the initial tumour location on CT1 was studied, evaluating the percentage of intersection volume. RESULTS: Twenty-eight patients participated in this study. In total, 13 patients (46.4%) had an intersection volume ≥ 50% and 10 patients (35.7%) had complete intersection (intersection volume = 100%). An increased median intersection volume was observed in patients with more than six clips (P = 0.007) and in patients with a larger portion of breast volume covered by the PBI-CTV (CTV/BV; P = 0.010). Intersection volume increased with the number of clips, after adjustment for CTV/BV (linear coefficient = 5.1693; P = 0.043). Also, a maximum distance from the chest wall ≤0.7 cm and CTV/BV > 9.5% were found to be predictors of an intersection volume ≥50% (area under the curve 0.841; confidence interval 0.649-0.952; P < 0.0001; area under the curve 0.800; confidence interval 0.607-0.926; P = 0.0004) and of an intersection volume of 100% (area under the curve 0.776, confidence interval 0.573-0.916, P = 0.046; area under the curve 0.752, confidence interval 0.536-0.935; P = 0.032). CONCLUSIONS: Titanium clips are essential and six or more increase the accuracy of tumour bed delineation for PBI; also the primary tumour location as well as the percentage of volume of breast covered by PBI-CTV may influence the correct delineation of PBI-CTV.


Subject(s)
Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Radiotherapy Planning, Computer-Assisted , Breast Neoplasms/diagnostic imaging , Female , Follow-Up Studies , Humans , Prognosis , Surgical Instruments/statistics & numerical data , Tomography, X-Ray Computed , Tumor Burden
6.
J Hum Nutr Diet ; 25(3): 201-8, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22257023

ABSTRACT

BACKGROUND: The role of nutritional counselling (NC) with or without oral nutritional supplements (ONS) in patients receiving chemoradiotherapy (CRT) for head and neck cancer (HNC) still remains to be clearly defined, particularly with regard to CRT-related toxicity. METHODS: Patients undergoing CRT for HNC received NC by the dietitian within the first 4 days of radiotherapy and weekly for the course of radiotherapy (approximately 6 weeks). A weekly supply of oral nutrition supplements [1560 kJ (373 kcal) per 100 g] for up to 3 months was provided to all patients. RESULTS: Twenty-one patients completed CRT. Mucositis G3 developed in seven (33.3%) patients, whereas mucositis G4 was absent. Dysphagia was present before the start of treatment in four patients. In the remaining 17 patients, dysphagia G3 developed during/at the end of treatment in five cases. The percentage of patients interrupting anti-neoplastic treatment for was 28% for ≥6 days, 28% for 3-5 days and 44% for 0-2 days. Mucositis G3 frequency was lower in patients with a baseline body mass index (BMI, kg m(-2) ) ≥25 (two out of 12; 16.6%) than in patients with BMI <25 (five out of nine; 55.5%) (P = 0.161) and in patients with a baseline mid arm circumference >30 cm than in those with a mid arm circumference in the range 28.1-30 cm and <28 cm, and higher in patients with a greater weight loss and a greater reduction of serum albumin and mid arm circumference. CONCLUSIONS: Nutritional counselling and ONS are associated with relatively low CRT-related toxicity and with mild deterioration of nutritional parameters.


Subject(s)
Chemoradiotherapy/adverse effects , Counseling , Dietetics/methods , Enteral Nutrition , Head and Neck Neoplasms/therapy , Malnutrition/therapy , Combined Modality Therapy , Dietary Supplements , Female , Head and Neck Neoplasms/complications , Humans , Male , Malnutrition/etiology , Middle Aged , Prospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...