Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Materials (Basel) ; 17(6)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38541567

ABSTRACT

This study aimed to evaluate the effect of two coating materials, a silicone sealing gel and a polytetrafluoroethylene (PTFE) tape, on the screw preload and removal torque value (RTV) to develop strategies to prevent prosthetic screw loosening. We examined 45 complexes comprising an implant, abutment, and prosthetic screw, of which 15 samples were uncoated, 15 were coated with GapSeal® (Hager & Werken GmbH & Co., Duisburg, Germany), and 15 were coated with PTFE tape (MIARCO®, Valencia, Spain). The screws were tightened to register the preload and then untightened to register the RTV. The preload values showed a statistically significant difference only in the PTFE group, suggesting that this lubricant negatively affects the preload. The RTVs showed statistically significant differences among all groups, with the GapSeal® group and PTFE group showing the highest and lowest values, respectively. It can be concluded that the application of the PTFE tape on the screw significantly reduced the preload and RTV. The silicone sealing gel did not affect the preload but increased the RTV. Therefore, the use of GapSeal® should be considered to prevent prosthetic screw loosening, while the use of PTFE tape should be avoided.

2.
Materials (Basel) ; 17(2)2024 Jan 16.
Article in English | MEDLINE | ID: mdl-38255602

ABSTRACT

STATEMENT OF PROBLEM: Implant-supported rehabilitations are an increasingly frequent practice to replace lost teeth. Before clinical application, all implant components should demonstrate suitable durability in laboratory studies, through fatigue tests. OBJECTIVE: The purpose of this in vitro study was to evaluate the integrity and wear of implant components using SEM, and to assess the axial displacement of the implant-abutment assembly by Micro-CT, in different implant connections, after three distinct mechanical requests. MATERIALS AND METHODS: Four KLOCKNER implants (external connection SK2 and KL; and internal connection VEGA and ESSENTIAL) were submitted to three different mechanical requests: single tightening, multiple tightening, and multiple tightening and cyclic loading (500 N × 100 cycles). A total of 16 samples were evaluated by SEM, by the X-ray Bragg-Brentano method to obtain residual stresses, and scratch tests were realized for each surface and Micro-CT (4 control samples; 4 single tightening; 4 multiple tightening; 4 multiple tightening and cyclic loading). All dental implants were fabricated with commercially pure titanium (grade 3 titanium). Surface topography and axial displacement of abutment into the implant, from each group, were evaluated by SEM and Micro-CT. RESULTS: In the manufacturing state, implants and abutments revealed minor structural changes and minimal damage from the machining process. The application of the tightening torque and loading was decisive in the appearance and increase in contact marks on the faces of the hexagon of the abutment and the implant. Vega has the maximum compressive residual stress and, as a consequence, higher scratch force. The abutment-implant distances in SK2 and KL samples did not show statistically significant differences, for any of the mechanical demands analyzed. In contrast, statistically significant differences were observed in abutment-implant distance in the internal connection implants Vega and Essential. CONCLUSIONS: The application of mechanical compression loads caused deformation and contact marks in all models tested. Only internal connection implants revealed an axial displacement of the abutment into the implant, but at a general level, a clear intrusion of the abutment into the implant could only be confirmed in the Essential model, which obtained its maximal axial displacement with cyclic loading.

3.
Polymers (Basel) ; 15(16)2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37631468

ABSTRACT

Implant-supported provisional restorations are critical for improving the esthetics and shaping of the peri-implant tissue. The mechanical properties of these provisional materials can be influenced by saliva, food, beverages, and interactions between these materials in the oral environment. Therefore, the integrity of provisional restorations should be preserved throughout the treatment period. This study aimed to evaluate the fracture strength of implant-supported polymethyl methacrylate (PMMA) provisional restorations made of computer-aided design and computer-aided manufacturing when immersed in different solutions at a controlled temperature of 37 °C for 7 days. Each analog-pillar-crown set was submerged in different liquids: 10 pieces were placed in distilled water then in tea, coffee, red wine, and Coca Cola® for 1 week at a controlled oral temperature of 37 °C. The samples were then subjected to fracture forces. The moment of fracture of the crown was recorded and compared with those of the other samples. Specimens immersed in distilled water (control group) had the highest fracture resistance (mean [M] = 1331.00 ± 296.74 N), while those immersed in tea had the lowest mean resistance to fracture (mean [M] = 967.00 ± 281.86 N). Nutritional deficiency and inappropriate eating habits influence the fracture strength of temporary crowns, thereby rendering them more elastic or less resistant to fractures.

4.
Biomedicines ; 11(6)2023 Jun 09.
Article in English | MEDLINE | ID: mdl-37371776

ABSTRACT

Dental-implant-supported reconstructions provide comfort and improvements in prosthetic function, adaptation, and stability over conventional treatment options. The objective of this study was to evaluate the effect of different denture cleansing solutions and their influence on the deterioration and loss of retention of overdenture attachments in a 12-month clinical-use simulation. In this way, ten specimens each of different brands of retentive caps made of Teflon (OT Equator® (Rhein83, Bologna, Italy), Locator® (Zest Anchors, Escondido, CA, USA), Kerator® (KJ Meditech, Gwangiu, Republic of Korea), and Locator R-Tx® (Zest Anchors, Escondido, CA, USA)) were immersed in five different cleaning solutions (Kukident® (P&G Tech, Oxford Parkway, UK), Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain), Corega® (Stafford Miller, Waterford, Ireland), and Protefix® (Neuhofer Weiche, Parchim, Germany)), and tap water was used as the control group, in a simulation that lasted 12 months. Data were analyzed using two-way ANOVA and a Tukey HSD. Furthermore, a Levene Test and Shapiro-Wilk tests were performed to assess the validation of the ANOVA assumptions. The statistical analysis was performed using R version 4.2.2 software with the significance level set to p < 0.05. There were significant statistical differences between the different manufacturers regarding the retention forces of the attachment's retentive caps (F = 322.066, p < 0.001). For the cleaning solution groups, different statistical results between Kukident® (P&G Tech, Oxford Parkway, UK) (p < 0.05) and Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain) (p < 0.05) were observed. There were no significant statistical differences between Corega® (Stafford Miller, Ireland), Protefix® (Neuhofer Weiche, Parchim, Germany), and tap water, even though the retention forces decreased in all of them.

5.
J Funct Biomater ; 14(2)2023 Jan 21.
Article in English | MEDLINE | ID: mdl-36826861

ABSTRACT

Temporary restorations play a fundamental role in oral rehabilitation. A properly adapted implant-supported provisional restoration implies better esthetics, contouring and architectural modeling of the upper peri-implant tissue. This study aimed to evaluate the influence of oral pH on the fracture resistance of implant-supported provisional restorations made with two brands of bis-acrylic resin (LuxaCrown® and Protemp™ 4) and to compare the fracture resistance of these two materials. Twenty crowns (ten manufactured using each brand) served as a control, and another forty crowns (twenty of each brand) were aged using artificial saliva with pHs of 4 or 7, for 7 days at 37 °C, in an attempt to simulate the behavior of these materials inside the oral cavity. Subsequently, all crowns were subjected to the application of a force at a constant speed, in a universal testing machine, until fracture was achieved. The LuxaCrown® brand showed greater resistance to fracture than the Protemp™ 4 brand. Salivary pH did not influence the fracture resistance of provisional LuxaCrown® crowns but did influence the fracture resistance of provisional Protemp™ 4 crowns.

6.
Materials (Basel) ; 15(19)2022 Sep 24.
Article in English | MEDLINE | ID: mdl-36233980

ABSTRACT

(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers. The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia's fracture resistance in relation to an average bite force of 250 N. (2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz). The study consisted of a traditional "load-to-failure" test. (3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.23 (p < 0.001), with this having a large effect size, d = 4.68. The 6 mm cantilever length (M = 442.30, sd = 47.49) was associated with a higher mean force at break than the 10 mm length (M = 215.18, sd = 40.74). No significant effect was found for the type of zirconia: t(38) = 0.31 (p = 0.757), and d = 0.10. (4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N. Cantilevers larger than 10 mm should be avoided.

7.
Dent J (Basel) ; 10(6)2022 Jun 15.
Article in English | MEDLINE | ID: mdl-35735654

ABSTRACT

With continuing technological developments, there have been advances in the field of fixed prosthetics, particularly in impression-taking techniques. These technological advances mean that a wide variety of diagnostic and/or rehabilitation possibilities can be explored without the need for physical models. The aim of this study was to evaluate the accuracy of three intraoral scanners used in oral implant rehabilitation using an extraoral scanner as a reference and varying the scanning area. Three models representing different clinical scenarios were scanned 15 times by each intraoral scanner and three times by the extraoral scanner. The readings were analyzed and overlaid using engineering software (Geomagic® Control X software (Artec Europe, Luxembourg)). Statistically significant differences in accuracy were found between the three intraoral scanners, iTero® (Align Technology Inc., San Jose, CA, USA), Medit® (Medit®: Seoul, Korea), and Planmeca® (Planmeca®: Helsinki, Finland). In all clinical scenarios, the iTero® scanner had the best trueness (24.4 µm), followed by the Medit® (26.4 µm) and Planmeca® (42.1 µm). The Medit® showed the best precision (18.00 µm) followed by the iTero® (19.20 µm) and Planmeca® (34.30 µm). We concluded that the iTero® scanner had the highest reproducibility and accuracy in the clinical setting.

8.
Polymers (Basel) ; 14(9)2022 Apr 26.
Article in English | MEDLINE | ID: mdl-35566919

ABSTRACT

(1) Introduction: Denture adhesives (DAs) promote stability, chewing ability, and quality of life. The objective of this study was to compare the effectiveness of original brand DAs and white brands in their retention of conventional complete dentures. (2) Methods: This study followed the recommendations of the international standard ISO 10873. Three original brands of DA (Corega® Fixação 3D, GlaxoSmithKline®, Stafford Miller Ltd., Dungarvan Co. Waterford, Ireland), KuKident® Pro Procter & Gamble Technical Centres®, Ltd., Whitehal Lane, Germany and Elgydium® Fix, Laboratórios URGO® SL, Florida, Spain) were compared to three white brands (Fixação Extra Forte Pingo Doce®, Laboratórios Cosmodent®, Cantabria, Spain), Fixador de Próteses (Continente®, Propack®,Gmbh, Ladenburg, Germany) and Creme Fixador de Próteses (Auchan®, Ellipse®, Roubaix, France). Their retention capacities were analyzed using a mechanical test device. (3) Results: The mean retentive ability of original brand adhesives (M = 11.16, SD = 5.27) was significantly higher (t(298) = 11.88; p < 0.001) than that of the white brands (M = 5.92, SD = 1.18). When comparing all brands, statistically significant differences were also observed, F(5.294) = 707.68 (p < 0.001). The generic adhesive results were more homogeneous. The generic brands from Continente® (M = 5.24, SD = 0.94) and Auchan® (M = 5.80, SD = 0.79) were not significantly different, while the Pingo Doce® brand obtained significantly higher mean retention results (M = 6.71, SD = 1.28). (4) Conclusions: The original brands of DA have a significantly higher retentive ability than the white brands. Elygidim® Fix had the worst result of the three original brands, and the product from Pingo Doce® had the best result among the three white brands.

9.
RGO (Porto Alegre) ; 70: e20220008, 2022. tab
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1365291

ABSTRACT

ABSTRACT Objective: The objective of the study was to investigate the effectiveness of a protocol of dental biofilm control designed based on an active learning strategy. Methods: A cross-sectional study was carried out with secondary data. The sample consisted of 42 patient records. Information about the patient´s knowledge, perception of oral health, and motor coordination was collected before and after the implementation of the protocol. The plaque index was used to evaluate the oral hygiene level of the patients. Results: At the first evaluation, the results of knowledge and perception were better than the ones of motor coordination. It was also observed a significant increase in the satisfactory percentages for the use of toothbrush and dental floss when comparing the first to the final evaluation. Moreover, there was a significant decrease in the plaque index through the appointments. There were no significant differences in the decrease of plaque index when comparing different genders and ages. However, there was a greater increase of satisfactory scores regarding oral health habits among men and younger age group. Conclusions: There was a significant reduction in the plaque index and an increase in the adoption of satisfactory health habits through the appointments. Although the decrease in plaque index was significant, it was still high, suggesting the need for a higher number of follow-up appointments to reinforce oral health habits.


RESUMO Objetivo: o objetivo do estudo foi avaliar a avaliar a efetividade de um protocolo de controle de biofilme dental embasado em uma metodologia ativa de educação em saúde. Methods: Foi realizado um estudo transversal com dados secundários. A amostra foi composta por 42 fichas clínicas de pacientes. Coletaram-se informações sobre conhecimento e percepção de saúde bucal, assim como habilidade motora do paciente no início e ao final da aplicação do protocolo. Utilizou-se o índice de placa dental para avaliar a saúde bucal. Results: Observou-se que, na avaliação inicial, os construtos de percepção apresentaram melhores resultados quando comparado aos construtos que avaliavam habilidade motora. Ao comparar os resultados obtidos na avaliação inicial e na final foi verificado aumento significativo de porcentagens satisfatórias no uso da escova e do fio dental. Além disso, houve redução significativa da média percentual do índice de placa ao longo das visitas registradas no protocolo. Não houve diferença significativa na redução do biofilme de acordo com gênero e idade, no entanto, observou-se maior evolução de porcentagens satisfatórias referentes a hábitos de saúde bucal entre homens e no grupo de menor faixa etária. Conclusions: Conclui-se que houve redução significativa dos índices de biofilme e maior incorporação de hábitos satisfatórios ao longo das consultas do protocolo. Apesar da redução significativa da média percentual do índice de placa, essa ainda se apresentou alta, sugerindo a necessidade de se incorporar um maior número de visitas e reforçar as ações de educação em saúde, para se obter resultados mais efetivos.

10.
Int J Dent ; 2021: 5133556, 2021.
Article in English | MEDLINE | ID: mdl-34899914

ABSTRACT

Micromovements of the implant-abutment connection influence peri-implant bone preservation. The maximal torque after a cycle of implant prosthetic screw tightening using original components of different manufacturers and replicas produced by other companies is evaluated and quantified in this study. A total of 30 Mis Seven® standard platform implants and 30 interfaces were used, and 30 standard platform screws were tested, 10 Mis®, 10 Iconekt®, and 10 Exaktus®. The screws were tightened with an MIS® torquemeter until their respective fracture, and the fracture point was measured through the equipment's load cell, CS-Dental Testing Machine®. The screws were analyzed under an Olympus® SZ61 microscope. The fracture points were recorded and compared among all samples. To compare the mean values of the fracture torques, t-tests were performed using the reference values associated with each brand and the sample results. The variable "Place of Fracture" between the original Mis® brand and the Exaktus® replica compared to the Iconekt® replica presented a statistically significant difference (p < 0.001). When analyzing the variable "Fracture Torque," although it was verified that the replica screws (Iconekt® and Exaktus®) had a lower maximum torque, 65.11 Nm and 62.89 Nm, respectively, compared to the original Mis® brand (70 Nm and 69 Nm), there were no statistically significant differences p > 0.05. Nonoriginal screws did not present different fracture resistances compared to the original Mis® brand screws. The fracture site of Iconekt® screws showed a different pattern compared to the other brands.

11.
Eur J Dent ; 15(4): 788-797, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34428850

ABSTRACT

This study aimed to review clinical publications involving anterior-region resin-bonded fixed partial dentures to evaluate their survival rates vis-à-vis their materials and design. An electronic search was conducted using PubMed/MEDLINE to identify articles that reported on the longevity of anterior resin-bonded fixed dental prostheses published between 2000 and 2020. Only primary clinical studies that involved a follow-up after at least 3 years were included in this review. A statistical analysis was performed to evaluate resin-bonded fixed dental prostheses' survival rates in relation to their materials and design. This review ultimately included 23 clinical publications, comprising prospective studies, retrospective studies, and randomized controlled trials. Its statistical analysis estimated the studied prostheses' 5-year survival rate at 86.2% for metal-framed prostheses, 87.9% for zirconia prostheses, 93.3% for alumina prostheses, 100% for glass or ceramic prostheses, and 81.7% for fiber-reinforced composite restorations. Failure rates did not significantly differ between the different material groups or between the single- and double-retainer groups. Resin-bonded fixed dental prostheses present excellent 5-year clinical longevity in the anterior sector and a favorable benefit/risk/cost ratio. Currently, no consensus has been established on an ideal material for these restorations. Cantilever design tends to limit constraints on the prostheses' retainers and, thus, increases their survival time. All-ceramic cantilever fixed partial dentures can be considered as a definitive therapy, given their high success and survival rates. They are an optimal solution for adolescents or young adults facing potentially continuous growth.

12.
Materials (Basel) ; 14(12)2021 Jun 15.
Article in English | MEDLINE | ID: mdl-34203948

ABSTRACT

The reinforcement of acrylic denture base remains problematic. Acrylic prosthesis fractures are commonly observed in prosthodontic practice and have not been reliably resolved. This study compared the resistance to masticatory force of acrylic bases of removable complete conventional prosthesis in 3D upper models. Forty acrylic base test specimens containing two types of reinforcement meshes (20 with glass fiber meshes (FIBER-FORCE®- Synca, Bio Composants MédicauxTM, Tullins, France), 20 with metal meshes (DENTAURUM®-Ispringen, Germany)), 20 with a conventional PMMA acrylic base (LUCITONE 199®-Dentsply Sirona, York, PA, USA), and 20 using a permanent soft reline material (MOLLOPLAST-B®-DETAX GmbH & Co. KG, Ettlingen, Germany) were tested-a total of 80 specimens. Half of the specimens were made for a low alveolar ridge and half for a high alveolar ridge. The data were analysed using one-way analysis of variance and Student's t-test for independent test specimens. In the high-alveolar-ridge group, the prosthesis reinforced with the glass fiber mesh was the most resistant to fracture, while in the low-alveolar-ridge group, the non-reinforced prosthesis showed the highest resistance masticatory force. Prostheses with the permanent soft reline material showed the lowest resistance to fracture in both high and low-alveolar-ridge groups. The results show that the selection of the right reinforcement material for each clinical case, based on the height of the alveolar ridge, may help to prevent prosthesis fractures.

13.
Polymers (Basel) ; 13(8)2021 Apr 11.
Article in English | MEDLINE | ID: mdl-33920377

ABSTRACT

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.

14.
Dent Med Probl ; 58(1): 61-68, 2021.
Article in English | MEDLINE | ID: mdl-33789002

ABSTRACT

BACKGROUND: In the past 20 years, several studies and clinical trials have reported similar results for transmucosal implants as compared to submerged implants. Several advantages of immediate loading have been pointed out, such as the reduction of treatment time, trauma reduction, and immediate esthetic and functional improvements. OBJECTIVES: The main objective of this study was to clinically evaluate the implant survival rate in patients with total rehabilitation via implants that underwent immediate loading in the past 5 years. MATERIAL AND METHODS: A cross-sectional, descriptive, observational analysis was conducted. The implant survival rate for an edentulous maxilla or mandible was assessed with regard to the loading protocol by means of a questionnaire and clinical observation. The study included 103 patients with edentulous jaws rehabilitated with fixed prostheses on implants. Each patient received 4-6 implants. In total, 474 implants were placed. Factors such as the implant survival rate as well as biological and prosthetic complications were evaluated and analyzed statistically. RESULTS: Of the 474 implants initially placed, 458 were considered osteointegrated and 16 were considered lost, which corresponds to a 96.62% implant survival rate. The most common types of failure were prosthetic fractures (46.2%), peri-implantitis (23.1%) and unscrewing (11.5%) in the first 5 years. CONCLUSIONS: The rate of osseointegration for implants placed under immediate loading was extremely high, in accordance with the previously published studies, which led us to conclude that currently, this is a surgical procedure with a high rate of success and high predictability.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Cross-Sectional Studies , Esthetics, Dental , Humans
15.
Int J Dent ; 2020: 8941876, 2020.
Article in English | MEDLINE | ID: mdl-33204269

ABSTRACT

METHODS: Ten prosthesis bases prepared with each brand of resin were subjected to neutral and low pH conditions (pH 7 and pH 4) by submerging them in artificial saliva for 30 days. After exposure, the fatigue resistance of the resins was tested using a Dental CS® Testing Machine. Statistical Analysis Test. The data sets were described quantitatively in terms of mean (M) and standard deviation (SD). Shapiro-Wilk tests and unilateral analysis of variance (ANOVA) were performed and complemented by Tukey's multiple comparison tests. The effect size (η2), whose cohort points followed Cohen's recommendations: 0.01 (low), 0.06 (medium), and 0.14 (high), was calculated. The results were considered significant if p < 0.05 and marginally significant if p < 0.10. RESULTS: One-way ANOVA showed that Megacryl® had the highest fracture resistance at pH 7 (52.23 Kgf), compared with Triplex Hot® (p < 0.001) and RS Vertex® (p=0.034). Two-way ANOVA confirmed the interaction between brand and pH (p=0.022), also revealing that brands comparison is significant or marginally significant, when pH is not considered (Megacryl® versus Triplex Hot®, p < 0.001, and RS Vertex®, p=0.058; Triplex Hot® versus RS Vertex®, p=0.051), and pH 7 results were significantly higher (p=0.003), even when brands are not considered. Hence, Megacryl® at pH 7 was found to have the highest fracture resistance, detached from other brands and pH values. CONCLUSION: It can be concluded within the limitations of this study that there are differences in the fracture resistance among the three brands of acrylic resin. Megacryl® was found to have the highest fracture resistance, and Triplex Hot® was the lowest. The results also show that exposure to a low pH environment decreases the fracture resistance of the Megacryl® and RS Vertex® resins.

16.
Dent J (Basel) ; 8(4)2020 Oct 09.
Article in English | MEDLINE | ID: mdl-33050156

ABSTRACT

Micromovements of the implant-abutment connection influence peri-implant bone preservation. This study evaluates and quantifies the maximal torque after a cycle of implant prosthetic screws tightening using original components. A total of 40 samples were tested: Megagen®-Daegu, South Korea; Dentium®-Gangnam-Gu, Seoul, Korea; BIOMET 3i®-West Palm Beach, FL, USA and BTI®-Álava, Spain. Screws from each manufacturer were subjected to maximal stress force until they fractured. The fracture points were recorded and compared among all samples. To compare the mean values of fracture torques, the reference values associated with each brand and the sample results were used in t-tests. ANOVA (analysis of variance) was used to compare the maximal resistance limit between brands, complemented with Tukey's multiple-comparison test. The maximal considered level of significance was 5%. The average fracture force for the brands was 40.07 Ncm for Megagen®, 53.39 Ncm for Dentium®, 39.74 Ncm for Biomet 3i®, and 68.84 Ncm for BTI®. BTI® screws showed the most resistance to fracture. According to the protocol that was applied, the implant-abutment connection demonstrated good resistance and a precise fit between these interfaces; therefore, in some cases, the presented values showed a lack of quality control and low fracture resistance.

17.
J Adv Prosthodont ; 8(1): 21-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26949484

ABSTRACT

PURPOSE: This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS: Three commercially available attachments were investigated: Clix®, Dalbo-Plus® and Locator®. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37℃. The abutments were placed at angulations of 0°, 10° and 20°. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS: The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F (2.48) = 343619, P<.05) and the type of attachment (F (7.48) = 23.220, P<.05). CONCLUSION: Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

18.
J Adv Prosthodont ; 7(1): 32-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25722835

ABSTRACT

PURPOSE: The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS: Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at 37℃ for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS: The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION: More acidic pH values were found to have a negative influence on the retention capacity of the attachments.

19.
Acta amaz ; 34(4): 513-524, out.-dez. 2004. graf, tab
Article in Portuguese | LILACS | ID: lil-512623

ABSTRACT

Este trabalho apresenta os resultados de análise fitossociológica e da estrutura, feita em 4 inventários florísticos executados em parcelas de 1 hectare de florestas inundáveis de várzea localizadas na área do estuário e do baixo Amazonas. As florestas de várzea do estuário albergam uma riqueza de espécies relativamente baixa em relação a outras áreas da região como as florestas de terra firme. No entanto a estrutura de tamanho é considerável, com as árvores atingindo elevada biomassa vegetal. Provavelmente isto é devido ao aporte constante de nutrientes através dos sedimentos que viajam milhares de quilômetros de distância desde as nascentes andinas até o delta do rio Amazonas. As florestas inundáveis de várzea são dominadas por poucas espécies, algumas com muitos indivíduos, como o açaí (Euterpe oleracea) e o muru-muru (Astrocaryum murumuru), outras com árvores muito grandes como a pitaíca (Swartzia polyphylla), pracuúba (Mora paraensis) e a seringueira (Hevea brasiliensis). A ucuúba (Virola surinamensis), uma espécie que apresenta populações ameaçadas pela exploração madeireira, parece apresentar tanto indivíduos grandes como elevada densidade. As florestas de várzea apresentam baixa similaridade entre si, provavelmente decorrente da imensa variação do ambiente de várzea nos rios, paranás, ilhas e lagos, como os efeitos de zonação, altura de inundação, salinidade, velocidade da água, entre outros fatores. Estratégias de seleção de áreas de várzea para conservação devem levar em conta a variação ambiental, o grau de interferência humana e a diversidade local e entre ambientes.


This work presents results of the analysis made in four 1-hectare plots of floristic inventory in the flooded forests located in the delta and lower basin of the Amazon river. The flooded forests, so called "várzea" forests, harbor a relatively low species richness in relation to other areas such as "terra firme" forests. However the structure in size is considerable, with trees attaining high plant biomass. Probably that is due to the constant contribution of nutrients through the sediments that travel thousands of kilometers from the watersheds of the Andes to the delta of the Amazon river. The flooded forests of "várzea" are dominated by very few species (oligarchic forests), some they with so many individuals such us the açaí (Euterpe oleracea) and the muru-muru (Astrocaryum murumuru) palms, another with very big trees like the pitaíca (Swartzia polyphylla), pracuúba (Mora paraensis) and the seringueira (Hevea brasiliensis). The ucuúba (Virola surinamensis), a species whose populations are threatened by the timber logging, it has both large trees and great abundance. The delta flooded forests have low similarity when compared to each other, probably due to the immense variation of the environment in rivers, channels, islands and lakes. Local effects such as topographic gradient, flood height, salinity, velocity of the water can strongly affect the diversity, abundance and distribution of plants. Strategies of selection of várzea areas for conservation should take into account the environmental variation, the degree of human interference and both local and the diversity between habitats.


Subject(s)
Botany , Estuaries , Amazonian Ecosystem , Rainforest
20.
World J Surg ; 27(7): 782-7, 2003 Jul.
Article in English | MEDLINE | ID: mdl-14509505

ABSTRACT

It is well stated in the literature that medical treatment for peptic ulcer is based on a combination of proton pump inhibitors (PPIs) and antibiotics to eradicate Helicobacter pylori. This treatment is associated with a high rate of immediate success and a low rate of recurrence at 12 months, although it is not effective in all patients. Peptic ulcer (PU) perforation is a serious problem that leads to high complication and mortality rates. Surgical treatment, with its various possibilities, constitutes the ideal treatment. Surgical intervention in these cases, however, can be directed to treating the perforation alone, or it can offer definitive treatment of the ulcer itself. With the hope of establishing why such complications and mortality were seen in the patients in our hospital population, we gathered the facts about PU perforations and the types of surgery performed. We studied 210 consecutive patients (150 men, 60 women) who had undergone surgery at our hospital because of perforation between January 1, 1990 and December 31, 2000. The patients' median age was 53.0 +/- 20.6 years (men 47.7 +/- 17.3 years; women 66.3 +/- 22.0 years). Altogether, 86 patients had significant associated illnesses, 62 were admitted more than 24 hours after the perforation, and 25 were admitted in shock. We performed resections in 10 patients; 88 patients were treated by suturing the perforation with or without a patch of epiploon; and 112 underwent a troncular vagotomy with drainage (VT + Dr). A total of 21 patients died (10%). Significant risk factors that led to complications were identified by statistical studies. They were a perforation that had been present more than 24 hours, the coexistence of significant associated illnesses, and resection surgery. The significant risk factors that led to death were the presence of shock at admission, the coexistence of significant illnesses, and resection surgery. There was no statistically significant difference concerning morbidity and mortality between simple closure of the perforation and definitive surgery (VT + Dr).


Subject(s)
Cause of Death , Gastrectomy/methods , Peptic Ulcer Perforation/mortality , Peptic Ulcer Perforation/surgery , Age Distribution , Aged , Analysis of Variance , Cohort Studies , Confidence Intervals , Female , Follow-Up Studies , Gastrectomy/mortality , Humans , Male , Middle Aged , Morbidity/trends , Odds Ratio , Peptic Ulcer Perforation/diagnosis , Portugal , Postoperative Complications/mortality , Probability , Risk Factors , Severity of Illness Index , Sex Distribution , Stomach Ulcer/diagnosis , Stomach Ulcer/mortality , Stomach Ulcer/surgery , Survival Rate
SELECTION OF CITATIONS
SEARCH DETAIL
...