Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Rev Bras Cir Cardiovasc ; 28(2): 208-16, 2013 Jun.
Article in English, Portuguese | MEDLINE | ID: mdl-23939317

ABSTRACT

OBJECTIVE: This paper demonstrates the initial and pioneering experience implant of the Inovare prosthesis implant through transfemoral or iliac artery route. METHODS: Six patients underwent transcatheter aortic valve implantation. The access was femoral or iliac through which the delivery device, a latex balloon catheter with the crimped prosthesis, was inserted. Through the femoral introducer 24 Fr Gore® DrySeal sheath, an extra stiff guide wire with non-traumatic tip was positioned in the left ventricle by passing through the valve ring. After balloon valvuloplasty, in cases of native valve stenosis, the prosthesis implantation was performed after hypotension induced by tachycardia and controlled by temporary pacemaker. The valve positioning was guided by TEE (transesophageal ecocardiography) and fluoroscopy, aiming to position a third of the length of the prosthesis into the left ventricle cavity. RESULTS: The successful valve implantation was possible in six cases. There was no need of conversion to open surgery due to inability to access or graft migration. There were no intraoperative or hospital deaths. We observed a significant reduction in the mean gradient of 66.84115.46 mmHg to 19.74110.61 mm Hg postoperatively (P=0.002), a reduction of 70.46%. CONCLUSION: Inovare prosthesis, implanted by femoral or iliac artery was feasible, and determined adequate hemodynamic performance in the postoperative follow-up, showing no mortality in this small series.


Subject(s)
Aortic Valve/surgery , Cardiac Catheterization/methods , Femoral Artery , Heart Valve Prosthesis Implantation/methods , Iliac Artery , Aged , Echocardiography , Feasibility Studies , Female , Heart Valve Prosthesis , Humans , Male , Middle Aged , Reproducibility of Results , Risk Factors , Treatment Outcome
2.
Rev. bras. cir. cardiovasc ; 28(2): 208-216, abr.-jun. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-682431

ABSTRACT

OBJETIVO: O presente trabalho tem por objetivo demonstrar a experiência inicial e pioneira do implante da prótese Inovare pela via transfemoral ou ilíaca. MÉTODOS: Seis pacientes foram submetidos ao implante valvar aórtico transcateter. A via de acesso foi femoral ou ilíaca, por onde foi inserido o dispositivo de entrega, que consiste em um cateter balão de látex com a prótese "crimpada" sobre o mesmo. Com auxílio de introdutor femoral da marca Gore® DrySeal 24 Fr, posicionava-se uma guia extrarrígida com a ponta atraumática no ventrículo esquerdo, passando-se pelo anel valvar. Após valvuloplastia com cateter balão nos casos de estenose valvar nativa, implante da prótese foi realizado após hipotensão induzida por taquicardia controlada por marcapasso temporário. O posicionamento da valva foi orientado por ecocardiograma transesofágico (ETE) e radioscopia, objetivando posicionar um terço da extensão da prótese para dentro da cavidade ventricular esquerda. RESULTADOS: O implante valvar com sucesso foi possível nos 6 casos. Não houve necessidade de conversão para cirurgia convencional por impossibilidade de acesso ou migração da prótese. Não houve mortalidade intraoperatória ou hospitalar. Houve redução significativa do gradiente médio pré-operatório de 66,84115,46 mmHg para 19,74110,61 mmHg, no pós-operatório (P=0,002), significando redução de 70,46%. CONCLUSÃO: A prótese Inovare, implantada por via femoral ou ilíaca, foi factível do ponto de vista técnico, apresentando adequado desempenho hemodinâmico no seguimento pós-operatório e não apresentando mortalidade nesta pequena casuística.


OBJECTIVE: This paper demonstrates the initial and pioneering experience implant of the Inovare prosthesis implant through transfemoral or iliac artery route. METHODS: Six patients underwent transcatheter aortic valve implantation. The access was femoral or iliac through which the delivery device, a latex balloon catheter with the crimped prosthesis, was inserted. Through the femoral introducer 24 Fr Gore® DrySeal sheath, an extra stiff guide wire with non-traumatic tip was positioned in the left ventricle by passing through the valve ring. After balloon valvuloplasty, in cases of native valve stenosis, the prosthesis implantation was performed after hypotension induced by tachycardia and controlled by temporary pacemaker. The valve positioning was guided by TEE (transesophageal ecocardiography) and fluoroscopy, aiming to position a third of the length of the prosthesis into the left ventricle cavity. RESULTS: The successful valve implantation was possible in six cases. There was no need of conversion to open surgery due to inability to access or graft migration. There were no intraoperative or hospital deaths. We observed a significant reduction in the mean gradient of 66.84115.46 mmHg to 19.74110.61 mm Hg postoperatively (P=0.002), a reduction of 70.46%. CONCLUSION: Inovare prosthesis, implanted by femoral or iliac artery was feasible, and determined adequate hemodynamic performance in the postoperative follow-up, showing no mortality in this small series.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Aortic Valve/surgery , Cardiac Catheterization/methods , Femoral Artery , Heart Valve Prosthesis Implantation/methods , Iliac Artery , Echocardiography , Feasibility Studies , Heart Valve Prosthesis , Reproducibility of Results , Risk Factors , Treatment Outcome
3.
Rev Bras Cir Cardiovasc ; 27(4): 645-7, 2012 Dec.
Article in English, Portuguese | MEDLINE | ID: mdl-23515739

ABSTRACT

Aortic dissection type A has a great mortality in its acute phase with low annual survival without surgical treatment. Although the chronic cases are exceptions the late complications exist and should be treated.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Dissection/complications , Endovascular Procedures/methods , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Humans , Male , Radiography
4.
Rev Bras Cir Cardiovasc ; 27(3): 469-71, 2012.
Article in English, Portuguese | MEDLINE | ID: mdl-23288191

ABSTRACT

We present a patient with severe aortic valvular bioprosthesis dysfunction implanted for 11 years, presenting with acute pulmonary edema due to severe valvular insufficiency with severe systolic dysfunction (EF <30%) and comorbid conditions that amounted operative risk (STS score > 10). We carried out the transcatheter aortic valve implantation (Inovare® - Braile Biomedica), which was implemented successfully by transfemoral access and good patient outcomes.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Cardiac Catheterization/methods , Femoral Artery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Aged , Humans , Male , Prosthesis Failure , Risk Assessment , Treatment Outcome
5.
Arq Bras Cardiol ; 79(1): 25-34, 2002 Jul.
Article in English, Portuguese | MEDLINE | ID: mdl-12163943

ABSTRACT

OBJECTIVE: To assess coronary stent placement in patients with multivessel coronary disease and involvement of the proximal portion of the anterior descending coronary artery. METHODS: We retrospectively analyzed the in-hospital and late evolution of 189 patients with multivessel coronary disease, who underwent percutaneous coronary stent placement. These patients were divided into 2 groups as follows: group I (GI) - 59 patients with involvement of the proximal segment of the anterior descending coronary artery; and group II (GII) - 130 patients without involvement of the proximal segment of the anterior descending coronary artery. RESULTS: No significant difference was observed in the success rate of the procedure (91.5% versus 97.6%, p=0.86), nor in the occurrence of major adverse cardiac events (5.1% versus 1.5%, p=0.38), nor in the occurrence of major vascular complications (1.7% versus 0%, p=0.69) in the in-hospital phase. In the late follow-up, the incidence of major adverse cardiac events (15.4% versus 13.7%, p=0.73) and the need for new revascularization (13.5% versus 10.3%, p=0.71) were similar for both groups. CONCLUSION: The in-hospital and late evolution of patients with multivessel coronary disease with and without involvement of the proximal segment of the anterior descending coronary artery treated with coronary stent placement did not differ. This suggests that this revascularization method is an effective procedure and a valuable option for treating these types of patients.


Subject(s)
Coronary Disease/therapy , Stents , Aged , Angioplasty, Balloon, Coronary , Chi-Square Distribution , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
6.
Arq. bras. cardiol ; 79(1): 25-34, July 2002. tab
Article in Portuguese, English | LILACS | ID: lil-316164

ABSTRACT

OBJECTIVE: To assess coronary stent placement in patients with multivessel coronary disease and involvement of the proximal portion of the anterior descending coronary artery. METHODS: We retrospectively analyzed the in-hospital and late evolution of 189 patients with multivessel coronary disease, who underwent percutaneous coronary stent placement. These patients were divided into 2 groups as follows: group I (GI) - 59 patients with involvement of the proximal segment of the anterior descending coronary artery; and group II (GII) - 130 patients without involvement of the proximal segment of the anterior descending coronary artery. RESULTS: No significant difference was observed in the success rate of the procedure (91.5 percent versus 97.6 percent, p=0.86), nor in the occurrence of major adverse cardiac events (5.1 percent versus 1.5 percent, p=0.38), nor in the occurrence of major vascular complications (1.7 percent versus 0 percent, p=0.69) in the in-hospital phase. In the late follow-up, the incidence of major adverse cardiac events (15.4 percent versus 13.7 percent, p=0.73) and the need for new revascularization (13.5 percent versus 10.3 percent, p=0.71) were similar for both groups. CONCLUSION: The in-hospital and late evolution of patients with multivessel coronary disease with and without involvement of the proximal segment of the anterior descending coronary artery treated with coronary stent placement did not differ. This suggests that this revascularization method is an effective procedure and a valuable option for treating these types of patients


Subject(s)
Humans , Male , Middle Aged , Coronary Disease , Stents , Angioplasty, Balloon, Coronary , Chi-Square Distribution , Follow-Up Studies , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...