1.
Trials ; 19(1): 702, 2018 12 24.
Article in English | MEDLINE | ID: mdl-30583740

ABSTRACT

After publication of our article [1] we became aware that several sections of text in our Methods section were copied from a previously published article [2].

2.
Trials ; 19(1): 71, 2018 Jan 26.
Article in English | MEDLINE | ID: mdl-29373998

ABSTRACT

BACKGROUND: Temporomandibular disorder (TMD) is described as a subgroup of orofacial pain with a set of signs and symptoms that involve the temporomandibular joint, masticatory muscles, ears, and neck. TMD can occur unilaterally or bilaterally and approximately 70% of the population is affected with at least one sign. The disorder progresses with orofacial pain, muscle pain involving the masticatory and cervical muscles, joint noises (clicks and pops), joint block, mandibular dysfunction, and headache. The etiology can be abnormal occlusion and/or posture, trauma involving local tissues, repetitive microtrauma, parafunctional habits, and an increase in emotional stress. Studies have demonstrated that phototherapy is an efficient option for the treatment of TMD, leading to improvements in pain and orofacial function. METHODS: The aim of the proposed study is to compare the effects of two sources of photobiomodulation in individuals with TMD. A randomized, controlled, double-blind, clinical trial is proposed, which will involve 80 individuals aged 18-65 years allocated to either a laser group or light-emitting diode (LED) group submitted to 12 sessions of phototherapy. The Research Diagnostic Criteria for TMDs will be used to evaluate all participants. Pain will be measured using the visual analog scale and maximum vertical mandibular movement will be determined with the aid of digital calipers. DISCUSSION: This study compares the effects of two modalities of laser therapy on the pain and orofacial function of patients with TMD dysfunction. Photobiomodulation and LED therapy are treatment options for reducing the inflammatory process and pain as well as inducing the regeneration of the target tissue. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03257748 . Registered on 8 August 2017.


Subject(s)
Low-Level Light Therapy/instrumentation , Masticatory Muscles/radiation effects , Temporomandibular Joint Disorders/radiotherapy , Temporomandibular Joint/radiation effects , Adolescent , Adult , Aged , Brazil , Double-Blind Method , Female , Humans , Low-Level Light Therapy/adverse effects , Male , Masticatory Muscles/physiopathology , Middle Aged , Pain Measurement , Randomized Controlled Trials as Topic , Recovery of Function , Temporomandibular Joint/physiopathology , Temporomandibular Joint Disorders/diagnosis , Temporomandibular Joint Disorders/physiopathology , Time Factors , Treatment Outcome , Young Adult
3.
Braz J Phys Ther ; 19(2): 137-45, 2015.
Article in English | MEDLINE | ID: mdl-25993627

ABSTRACT

BACKGROUND: Handgrip strength is currently considered a predictor of overall muscle strength and functional capacity. Therefore, it is important to find reliable and affordable instruments for this analysis, such as the modified sphygmomanometer test (MST). OBJECTIVES: To assess the concurrent criterion validity of the MST, to compare the MST with the Jamar dynamometer, and to analyze the reproducibility (i.e. reliability and agreement) of the MST in individuals with Parkinson's disease (PD). METHOD: The authors recruited 50 subjects, 24 with PD (65.5 ± 6.2 years of age) and 26 healthy elderly subjects (63.4 ± 7.2 years of age). The handgrip strength was measured using the Jamar dynamometer and modified sphygmomanometer. The concurrent criterion validity was analyzed using Pearson's correlation coefficient and a simple linear regression test. The reproducibility of the MST was evaluated with the coefficient of intra-class correlation (ICC(2,1)), the standard error of measurement (SEM), the minimal detectable change (MDC), and the Bland-Altman plot. For all of the analyses, α ≤ 0.05 was considered a risk. RESULTS: There was a significant correlation of moderate magnitude (r ≥ 0.45) between the MST and the Jamar dynamometer. The MST had excellent reliability (ICC(2,1) ≥ 0.7). The SEM and the MDC were adequate; however, the Bland-Altman plot indicated an unsatisfactory interrater agreement. CONCLUSIONS: The MST exhibited adequate validity and excellent reliability and is, therefore, suitable for monitoring the handgrip strength in PD. However, if the goal is to compare the measurements between examiners, the authors recommend that the data be interpreted with caution.


Subject(s)
Hand Strength , Parkinson Disease/physiopathology , Sphygmomanometers , Aged , Equipment Design , Female , Humans , Male , Middle Aged , Reproducibility of Results
4.
Braz. j. phys. ther. (Impr.) ; 19(2): 137-145, 27/04/2015. tab, graf
Article in English | LILACS | ID: lil-745809

ABSTRACT

BACKGROUND: Handgrip strength is currently considered a predictor of overall muscle strength and functional capacity. Therefore, it is important to find reliable and affordable instruments for this analysis, such as the modified sphygmomanometer test (MST). OBJECTIVES: To assess the concurrent criterion validity of the MST, to compare the MST with the Jamar dynamometer, and to analyze the reproducibility (i.e. reliability and agreement) of the MST in individuals with Parkinson's disease (PD). METHOD: The authors recruited 50 subjects, 24 with PD (65.5±6.2 years of age) and 26 healthy elderly subjects (63.4±7.2 years of age). The handgrip strength was measured using the Jamar dynamometer and modified sphygmomanometer. The concurrent criterion validity was analyzed using Pearson's correlation coefficient and a simple linear regression test. The reproducibility of the MST was evaluated with the coefficient of intra-class correlation (ICC2,1), the standard error of measurement (SEM), the minimal detectable change (MDC), and the Bland-Altman plot. For all of the analyses, α≤0.05 was considered a risk. RESULTS: There was a significant correlation of moderate magnitude (r≥0.45) between the MST and the Jamar dynamometer. The MST had excellent reliability (ICC2,1≥0.7). The SEM and the MDC were adequate; however, the Bland-Altman plot indicated an unsatisfactory interrater agreement. CONCLUSIONS: The MST exhibited adequate validity and excellent reliability and is, therefore, suitable for monitoring the handgrip strength in PD. However, if the goal is to compare the measurements between examiners, the authors recommend that the data be interpreted with caution. .


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Parkinson Disease/physiopathology , Hand Strength , Sphygmomanometers , Reproducibility of Results , Equipment Design