Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Publication year range
1.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1492812

ABSTRACT

It were established correlations among methods of sperm plasmatic membrane evaluation, by analyzing cryopreserved semen of five Nelore bulls, within three replicates / bull. After thawing at 37C/30 seconds, there were assessed motility (%), concentration (x106), morphology (%) and membrane integrity. To evaluate membrane integrity, hypoosmotic test (HOS), fluorescence (FLU) and eosin/nigrosin (EN) were used. Data were submitted to Pearson´s correlation analysis. According to the results, there was correlation between fluorescence vs eosin/nigrosin (r = 0.74; p


O objetivo, com este trabalho, foi verificar a correlação entre métodos de avaliação da integridade da membrana plasmática (IMP), no sêmen congelado comercial de cinco touros da raça Nelore, com três repetições por animal. Após o descongelamento a 37C/30 segundos, foram analisadas as variáveis motilidade (%), concentração (x106/ml), morfologia (%) e IMP. Para a avaliação da IMP, foram usados o teste hiposmótico (HOS), fluorescência (FLU) e eosina/nigrosina (EN), e contadas 100 células/lâmina. Os dados foram submetidos à análise de correlação de Pearson. Houve correlação entre as técnicas de fluorescência vs eosina/nigrosina (r = 0,74; p

2.
Article in Portuguese | VETINDEX | ID: vti-711875

ABSTRACT

It were established correlations among methods of sperm plasmatic membrane evaluation, by analyzing cryopreserved semen of five Nelore bulls, within three replicates / bull. After thawing at 37C/30 seconds, there were assessed motility (%), concentration (x106), morphology (%) and membrane integrity. To evaluate membrane integrity, hypoosmotic test (HOS), fluorescence (FLU) and eosin/nigrosin (EN) were used. Data were submitted to Pearson´s correlation analysis. According to the results, there was correlation between fluorescence vs eosin/nigrosin (r = 0.74; p


O objetivo, com este trabalho, foi verificar a correlação entre métodos de avaliação da integridade da membrana plasmática (IMP), no sêmen congelado comercial de cinco touros da raça Nelore, com três repetições por animal. Após o descongelamento a 37C/30 segundos, foram analisadas as variáveis motilidade (%), concentração (x106/ml), morfologia (%) e IMP. Para a avaliação da IMP, foram usados o teste hiposmótico (HOS), fluorescência (FLU) e eosina/nigrosina (EN), e contadas 100 células/lâmina. Os dados foram submetidos à análise de correlação de Pearson. Houve correlação entre as técnicas de fluorescência vs eosina/nigrosina (r = 0,74; p

SELECTION OF CITATIONS
SEARCH DETAIL