Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
Add more filters











Publication year range
2.
J Cardiovasc Electrophysiol ; 35(4): 654-663, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38288888

ABSTRACT

INTRODUCTION: In hypertrophic cardiomyopathy (HCM), atrial fibrillation (AF) has historically been regarded to have a deleterious impact on clinical course, strongly associated with progressive heart failure (HF) symptoms. However, there is a paucity of information regarding the impact of AF on HCM employing validated quality of life (QoL) surveys. Therefore, we evaluated the impact of AF on QoL utilizing patient reported outcome measures (PROMs). METHODS: 218 consecutive HCM patients with or without AF at the Lahey HCM center in 2022 completed PROMs at their most recent visit evaluating HF (Kansas City Cardiomyopathy Questionnaire [KCCQ]) and AF symptoms (AF Effect on QoL [AFEQT]). RESULTS: Among the 218 patients, 50 (23%) had a history of AF and comprise the primary study cohort. AF was diagnosed at 55 ± 10 years of age, median of 5.5 years before PROM, with 66% of patients treated with a rhythm control strategy with antiarrhythmic drug and/or AF ablation. AFEQT indicated that 52% of patients experienced no or minimal AF-related disability, mild to moderate in 22%, and severe in 26%. There was no substantial difference in HCM phenotype in patients with no or minimal AF disability compared to those with severe disability. HF symptoms for most HCM patients with prior AF history was consistent with no or minimal (59%) or only mild (27%) disability as measured by KCCQ overall summary scores. In addition, with multivariate analysis, AF history was associated with less HF symptoms and improved QoL (OR 0.4, p = 0.02). CONCLUSION: In contrast to prior perceptions, HCM patients with prior AF history were less likely to incur HF symptoms impairing QoL compared to HCM patients without AF. After treatment, prior history of AF did not substantially impact current QoL. These data provide a realistic appraisal for the impact that AF has on HCM patients and also offers a measure of reassurance for this patient subgroup.


Subject(s)
Atrial Fibrillation , Cardiomyopathy, Hypertrophic , Vascular Diseases , Humans , Quality of Life , Anti-Arrhythmia Agents/therapeutic use , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/therapy , Vascular Diseases/complications
3.
Circ Arrhythm Electrophysiol ; 13(12): e009288, 2020 12.
Article in English | MEDLINE | ID: mdl-33185144

ABSTRACT

BACKGROUND: The limited effectiveness of endocardial catheter ablation (CA) for persistent and long-standing persistent atrial fibrillation (AF) treatment led to the development of a minimally invasive epicardial/endocardial ablation approach (Hybrid Convergent) to achieve a more comprehensive lesion set with durable transmural lesions. The multicenter randomized controlled CONVERGE trial (Convergence of Epicardial and Endocardial Ablation for the Treatment of Symptomatic Persistent AF) evaluated the safety of Hybrid Convergent and compared its effectiveness to CA for persistent and long-standing persistent AF treatment. METHODS: One-hundred fifty-three patients were randomized 2:1 to Hybrid Convergent versus CA. Primary effectiveness was freedom from AF/atrial flutter/atrial tachycardia absent new/increased dosage of previously failed/intolerant class I/III antiarrhythmic drugs through 12 months. Primary safety was major adverse events through 30 days. CONVERGE permitted left atrium size up to 6 cm and imposed no limits on AF duration, making it the only ablation trial to substantially include long-standing persistent-AF, that is, 42% patients with long-standing persistent-AF. RESULTS: Of 149 evaluable patients at 12 months, primary effectiveness was achieved in 67.7% (67/99) patients with Hybrid Convergent and 50.0% (25/50) with CA (P=0.036) on/off previously failed antiarrhythmic drugs and in 53.5% (53/99) versus 32.0% (16/50; P=0.0128) respectively off antiarrhythmic drugs. At 18 months using 7-day Holter, 74.0% (53/72) Hybrid Convergent and 55% (23/42) CA patients experienced ≥90% AF burden reduction. A total of 2.9% (3/102) patients had primary safety events within 7 days, and 4.9% (5/102) between 8 and 30 days postprocedure. No deaths, cardiac perforations, or atrioesophageal fistulas occurred. All but one primary safety event resolved. CONCLUSIONS: The Hybrid Convergent procedure has superior effectiveness compared to the CA for the treatment of persistent and long-standing persistent atrial fibrillation. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01984346.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Female , Heart Rate , Humans , Male , Middle Aged , Prospective Studies , Pulmonary Veins/physiopathology , Recurrence , Time Factors , Treatment Outcome , United Kingdom , United States
4.
Respir Res ; 21(1): 77, 2020 Mar 30.
Article in English | MEDLINE | ID: mdl-32228581

ABSTRACT

BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a heterogeneous disease characterized by frequent exacerbation phenotypes independent of disease stage. Increasing evidence shows that the microbiota plays a role in disease progression and severity, but long-term and international multicenter assessment of the variations in viral and bacterial communities as drivers of exacerbations are lacking. METHODS: Two-hundred severe COPD patients from Europe and North America were followed longitudinally for 3 years. We performed nucleic acid detection for 20 respiratory viruses and 16S ribosomal RNA gene sequencing to evaluate the bacterial microbiota in 1179 sputum samples collected at stable, acute exacerbation and follow-up visits. RESULTS: Similar viral and bacterial taxa were found in patients from the USA compared to Bulgaria and Czech Republic but their microbiome diversity was significantly different (P < 0.001) and did not impact exacerbation rates. Virus infection was strongly associated with exacerbation events (P < 5E-20). Human rhinovirus (13.1%), coronavirus (5.1%) and influenza virus (3.6%) constitute the top viral pathogens in triggering exacerbation. Moraxella and Haemophilus were 5-fold and 1.6-fold more likely to be the dominating microbiota during an exacerbation event. Presence of Proteobacteria such as Pseudomonas or Staphylococcus amongst others, were associated with exacerbation events (OR > 0.17; P < 0.02) but more strongly associated with exacerbation frequency (OR > 0.39; P < 4E-10), as confirmed by longitudinal variations and biotyping of the bacterial microbiota, and suggesting a role of the microbiota in sensitizing the lung. CONCLUSIONS: This study highlights bacterial taxa in lung sensitization and viral triggers in COPD exacerbations. It provides a global overview of the diverse targets for drug development and explores new microbiome analysis methods to guide future patient management applications.


Subject(s)
Bacteria/isolation & purification , Lung/microbiology , Lung/virology , Pulmonary Disease, Chronic Obstructive/microbiology , Pulmonary Disease, Chronic Obstructive/virology , Viruses/isolation & purification , Aged , Aged, 80 and over , Bacteria/genetics , Bacterial Load , Disease Progression , Europe/epidemiology , Female , Humans , Incidence , Longitudinal Studies , Male , Middle Aged , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/epidemiology , Retrospective Studies , Risk Factors , Sputum/microbiology , Sputum/virology , Time Factors , United States/epidemiology , Viral Load , Viruses/genetics
5.
JACC Case Rep ; 2(5): 796-801, 2020 May.
Article in English | MEDLINE | ID: mdl-34317350

ABSTRACT

We present the case of a 57-year-old man with a primary prevention internal cardioverter-defibrillator for severe nonischemic cardiomyopathy. At the time of elective replacement indicator, systolic function had fully recovered, and his generator was not changed. Nearly 5 years post-elective replacement indicator he received appropriate internal cardioverter-defibrillator therapies during a myocardial infarction. (Level of Difficulty: Intermediate.).

7.
Nat Immunol ; 18(9): 959-960, 2017 08 22.
Article in English | MEDLINE | ID: mdl-28829441
8.
Cell Rep ; 18(8): 1906-1916, 2017 02 21.
Article in English | MEDLINE | ID: mdl-28228257

ABSTRACT

Long-lived plasma cells (PCs) in the bone marrow (BM) are a critical source of antibodies after infection or vaccination, but questions remain about the factors that control PCs. We found that systemic infection alters the BM, greatly reducing PCs and regulatory T (Treg) cells, a population that contributes to immune privilege in the BM. The use of intravital imaging revealed that BM Treg cells display a distinct behavior characterized by sustained co-localization with PCs and CD11c-YFP+ cells. Gene expression profiling indicated that BM Treg cells express high levels of Treg effector molecules, and CTLA-4 deletion in these cells resulted in elevated PCs. Furthermore, preservation of Treg cells during systemic infection prevents PC loss, while Treg cell depletion in uninfected mice reduced PC populations. These studies suggest a role for Treg cells in PC biology and provide a potential target for the modulation of PCs during vaccine-induced humoral responses or autoimmunity.


Subject(s)
Bone Marrow Cells/immunology , Bone Marrow/immunology , Plasma Cells/immunology , T-Lymphocytes, Regulatory/immunology , Animals , Autoimmunity/immunology , CTLA-4 Antigen/immunology , Immunity, Humoral , Immunophenotyping/methods , Mice , Mice, Inbred C57BL
SELECTION OF CITATIONS
SEARCH DETAIL