Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 118
Filter
1.
Article in English | MEDLINE | ID: mdl-38744354

ABSTRACT

Left ventricular assist devices (LVADs) are excellent therapies for advanced heart failure patients either bridged to transplant or for lifetime use. LVADs also allow for reverse remodeling of the failing heart that is often associated with functional improvement. Indeed, growing enthusiasm exists to better understand this population of patients, whereby the LVAD is used as an adjunct to mediate myocardial recovery. When patients achieve benchmarks suggesting that they no longer need LVAD support, questions related to the discontinuation of LVAD therapy become front and center. The purpose of this review is to provide a surgical perspective on the practical and technical issues surrounding LVAD deactivation.

2.
Circ Heart Fail ; 17(5): e010904, 2024 May.
Article in English | MEDLINE | ID: mdl-38602105

ABSTRACT

BACKGROUND: Heart transplant (HT) in recipients with left ventricular assist devices (LVADs) is associated with poor early post-HT outcomes, including primary graft dysfunction (PGD). As complicated heart explants in recipients with LVADs may produce longer ischemic times, innovations in donor heart preservation may yield improved post-HT outcomes. The SherpaPak Cardiac Transport System is an organ preservation technology that maintains donor heart temperatures between 4 °C and 8 °C, which may minimize ischemic and cold-induced graft injuries. This analysis sought to identify whether the use of SherpaPak versus traditional cold storage was associated with differential outcomes among patients with durable LVAD undergoing HT. METHODS: Global Utilization and Registry Database for Improved Heart Preservation-Heart (NCT04141605) is a multicenter registry assessing post-HT outcomes comparing 2 methods of donor heart preservation: SherpaPak versus traditional cold storage. A retrospective review of all patients with durable LVAD who underwent HT was performed. Outcomes assessed included rates of PGD, post-HT mechanical circulatory support use, and 30-day and 1-year survival. RESULTS: SherpaPak (n=149) and traditional cold storage (n=178) patients had similar baseline characteristics. SherpaPak use was associated with reduced PGD (adjusted odds ratio, 0.56 [95% CI, 0.32-0.99]; P=0.045) and severe PGD (adjusted odds ratio, 0.31 [95% CI, 0.13-0.75]; P=0.009), despite an increased total ischemic time in the SherpaPak group. Propensity matched analysis also noted a trend toward reduced intensive care unit (SherpaPak 7.5±6.4 days versus traditional cold storage 11.3±18.8 days; P=0.09) and hospital (SherpaPak 20.5±11.9 days versus traditional cold storage 28.7±37.0 days; P=0.06) lengths of stay. The 30-day and 1-year survival was similar between groups. CONCLUSIONS: SherpaPak use was associated with improved early post-HT outcomes among patients with LVAD undergoing HT. This innovation in preservation technology may be an option for HT candidates at increased risk for PGD. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04141605.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Organ Preservation , Registries , Humans , Male , Female , Middle Aged , Organ Preservation/methods , Retrospective Studies , Heart Failure/therapy , Heart Failure/physiopathology , Heart Failure/surgery , Heart Failure/mortality , Treatment Outcome , Adult , Aged , Primary Graft Dysfunction , Time Factors
3.
J Heart Lung Transplant ; 43(7): 1153-1161, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38503386

ABSTRACT

BACKGROUND: Severe primary graft dysfunction (PGD) is a major cause of early mortality after heart transplant, but the impact of donor organ preservation conditions on severity of PGD and survival has not been well characterized. METHODS: Data from US adult heart-transplant recipients in the Global Utilization and Registry Database for Improved Heart Preservation-Heart Registry (NCT04141605) were analyzed to quantify PGD severity, mortality, and associated risk factors. The independent contributions of organ preservation method (traditional ice storage vs controlled hypothermic preservation) and ischemic time were analyzed using propensity matching and logistic regression. RESULTS: Among 1,061 US adult heart transplants performed between October 2015 and December 2022, controlled hypothermic preservation was associated with a significant reduction in the incidence of severe PGD compared to ice (6.6% [37/559] vs 10.4% [47/452], p = 0.039). Following propensity matching, severe PGD was reduced by 50% (6.0% [17/281] vs 12.1% [34/281], respectively; p = 0.018). The Kaplan-Meier terminal probability of 1-year mortality was 4.2% for recipients without PGD, 7.2% for mild or moderate PGD, and 32.1%, for severe PGD (p < 0.001). The probability of severe PGD increased for both cohorts with longer ischemic time, but donor hearts stored on ice were more likely to develop severe PGD at all ischemic times compared to controlled hypothermic preservation. CONCLUSIONS: Severe PGD is the deadliest complication of heart transplantation and is associated with a 7.8-fold increase in probability of 1-year mortality. Controlled hypothermic preservation significantly attenuates the risk of severe PGD and is a simple yet highly effective tool for mitigating post-transplant morbidity.


Subject(s)
Heart Transplantation , Organ Preservation , Humans , Organ Preservation/methods , Female , Male , Middle Aged , Primary Graft Dysfunction/prevention & control , Primary Graft Dysfunction/epidemiology , Primary Graft Dysfunction/etiology , Registries , Adult , Retrospective Studies , Risk Factors , United States/epidemiology , Survival Rate/trends , Tissue Donors , Graft Survival , Aged
4.
Article in English | MEDLINE | ID: mdl-38367698

ABSTRACT

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

5.
ASAIO J ; 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38386980

ABSTRACT

Data regarding outcomes with Impella 5.5 are limited. The aim of this systematic review and meta-analysis was to summarize patient and treatment characteristics and early clinical outcomes among patients supported by Impella 5.5. A systematic literature search was conducted in PubMed, Scopus, and Cochrane databases from September 2019 to March 2023. Studies reporting outcomes in greater than or equal to 5 patients were included for review. Patient characteristics, treatment characteristics, and early clinical outcomes were extracted. Outcomes included adverse events, survival to hospital discharge, and 30 day survival. Random-effect models were used to estimate pooled effects for survival outcomes. Assessment for bias was performed using funnel plots and Egger's tests. Fifteen studies were included for qualitative review, representing 707 patients. Mean duration of support was 9.9 ± 8.2 days. On meta-analysis of 13 studies reporting survival outcomes, survival to hospital discharge was 68% (95% confidence interval [CI], 58-78%), and 30 day survival was 65% (95% CI, 56-74%) among patients with Impella devices predominantly supported by Impella 5.5 (>60%). There was significant study heterogeneity for these outcomes. Among 294 patients with Impella 5.5 only, survival to discharge was 78% (95% CI, 72-82%) with no significant study heterogeneity. This data present early benchmarks for outcomes with Impella 5.5 as clinical experience with these devices accrues.

6.
ASAIO J ; 70(5): 388-395, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38300893

ABSTRACT

The last several years have seen a rise in use of mechanical circulatory support (MCS) to bridge heart transplant recipients. A controlled hypothermic organ preservation system, the SherpaPak Cardiac Transport System (SCTS), was introduced in 2018 and has grown in utilization with reports of improved posttransplant outcomes. The Global Utilization And Registry Database for Improved heArt preservatioN (GUARDIAN)-Heart registry is an international, multicenter registry assessing outcomes after transplant using the SCTS. This analysis examines outcomes in recipients bridged with various MCS devices in the GUARDIAN-Heart Registry. A total of 422 recipients with donor hearts transported using SCTS were included and identified. Durable ventricular assist devices (VADs) were used exclusively in 179 recipients, temporary VADs or intra-aortic balloon pump (IABP) in 197, and extracorporeal membrane oxygenation (ECMO) in 14 recipients. Average ischemic times were over 3.5 hours in all cohorts. Severe primary graft dysfunction (PGD) posttransplant increased across groups (4.5% VAD, 5.1% temporary support, 21.4% ECMO), whereas intensive care unit (ICU) length of stay (18.2 days) and total hospital stay (39.4 days) was longer in the ECMO cohort than the VAD and IABP groups. A comparison of outcomes of MCS bridging in SCTS versus traditional ice revealed significantly lower rates of both moderate/severe right ventricular (RV) dysfunction and severe PGD in the SCTS cohort; however, upon propensity matching only the reductions in moderate/severe RV dysfunction were statistically significant. Use of SCTS in transplant recipients with various bridging strategies results in excellent outcomes.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Transplantation , Heart-Assist Devices , Humans , Heart Transplantation/methods , Male , Middle Aged , Female , Adult , Extracorporeal Membrane Oxygenation/methods , Organ Preservation/methods , Treatment Outcome , Registries/statistics & numerical data , Intra-Aortic Balloon Pumping/methods , Intra-Aortic Balloon Pumping/statistics & numerical data , Aged , Retrospective Studies
7.
JACC Heart Fail ; 12(3): 438-447, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38276933

ABSTRACT

BACKGROUND: Extended criteria donor (ECD) hearts available with donation after brain death (DBD) are underutilized for transplantation due to limitations of cold storage. OBJECTIVES: This study evaluated use of an extracorporeal perfusion system on donor heart utilization and post-transplant outcomes in ECD DBD hearts. METHODS: In this prospective, single-arm, multicenter study, adult heart transplant recipients received ECD hearts using an extracorporeal perfusion system if hearts met study criteria. The primary outcome was a composite of 30-day survival and absence of severe primary graft dysfunction (PGD). Secondary outcomes were donor heart utilization rate, 30-day survival, and incidence of severe PGD. The safety outcome was the mean number of heart graft-related serious adverse events within 30 days. Additional outcomes included survival through 2 years benchmarked to concurrent nonrandomized control subjects. RESULTS: A total of 173 ECD DBD hearts were perfused; 150 (87%) were successfully transplanted; 23 (13%) did not meet study transplantation criteria. At 30 days, 92% of patients had survived and had no severe PGD. The 30-day survival was 97%, and the incidence of severe PGD was 6.7%. The mean number of heart graft-related serious adverse events within 30 days was 0.17 (95% CI: 0.11-0.23). Patient survival was 93%, 89%, and 86% at 6, 12, and 24 months, respectively, and was comparable with concurrent nonrandomized control subjects. CONCLUSIONS: Use of an extracorporeal perfusion system resulted in successfully transplanting 87% of donor hearts with excellent patient survival to 2 years post-transplant and low rates of severe PGD. The ability to safely use ECD DBD hearts could substantially increase the number of heart transplants and expand access to patients in need. (International EXPAND Heart Pivotal Trial [EXPANDHeart]; NCT02323321; Heart EXPAND Continued Access Protocol; NCT03835754).


Subject(s)
Heart Failure , Heart Transplantation , Adult , Humans , Graft Survival , Heart Failure/surgery , Heart Transplantation/methods , Organ Preservation/methods , Prospective Studies , Retrospective Studies , Tissue Donors
8.
J Heart Lung Transplant ; 43(4): 673-680, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38163452

ABSTRACT

BACKGROUND: The prevalence of end-stage heart failure and patients who could benefit from heart transplantation requires an expansion of the donor pool, relying on the transplant community to continually re-evaluate and expand the use of extended criteria donor organs. Introduction of new technologies such as the Paragonix SherpaPak Cardiac Transport System aids in this shift. We seek to analyze the impact of the SherpaPak system on recipient outcomes who receive extended criteria organs in the GUARDIAN-Heart Registry. METHODS: Between October 2015 and December 2022, 1,113 adults from 15 US centers receiving donor hearts utilizing either SherpaPak (n = 560) or conventional ice storage (ice, n = 453) were analyzed from the GUARDIAN-Heart Registry using summary statistics. A previously published set of criteria was used to identify extended criteria donors, which included 193 SherpaPak and 137 ice. RESULTS: There were a few baseline differences among recipients in the 2 cohorts; most notably, IMPACT scores, distance traveled, and total ischemic time were significantly greater in SherpaPak, and significantly more donor hearts in the SherpaPak cohort had >4 hours total ischemia time. Posttransplant mechanical circulatory support utilization (SherpaPak 22.3% vs ice 35.0%, p = 0.012) and new extracorporeal membrane oxygenation/ventricular assist device (SherpaPak 7.8% vs ice 15.3%, p = 0.033) was significantly reduced, and the rate of severe primary graft dysfunction (SherpaPak 6.2% vs ice 13.9%, p = 0.022) was significantly reduced by over 50% in hearts preserved using SherpaPak. One-year survival between cohorts was similar (SherpaPak 92.9% vs ice 89.6%, p = 0.27). CONCLUSIONS: This subgroup analysis demonstrates that SherpaPak can be safely used to utilize extended criteria donors with low severe PGD rates.


Subject(s)
Heart Transplantation , Tissue Donors , Adult , Humans , Ice , Heart , Registries , Retrospective Studies
9.
J Thorac Cardiovasc Surg ; 167(5): 1819-1820, 2024 May.
Article in English | MEDLINE | ID: mdl-36639286
10.
Ann Surg ; 279(3): 383-384, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38050726
11.
J Thorac Cardiovasc Surg ; 167(5): 1864-1865, 2024 May.
Article in English | MEDLINE | ID: mdl-37852359
12.
J Cardiothorac Surg ; 18(1): 358, 2023 Dec 09.
Article in English | MEDLINE | ID: mdl-38071382

ABSTRACT

BACKGROUND: Hemopericardium is a serious complication that can occur after cardiac surgery. While most post-operative causes are due to inflammation and bleeding, patients with broken sternal wires and an unstable sternum may develop hemopericardium from penetrating trauma. CASE PRESENTATION: We present the case of a 62-year-old male who underwent triple coronary bypass surgery and presented five months later with sudden anterior chest wall pain. Chest computed tomography revealed hemopericardium with an associated broken sternal wire that had penetrated into the pericardial space. The patient underwent a redo-sternotomy which revealed a 3.5 cm bleeding, jagged right ventricular laceration that correlated to the imaging findings of a fractured sternal wire projecting in the pericardial space. The laceration was repaired using interrupted 4 - 0 polypropylene sutures in horizontal mattress fashion between strips of bovine pericardium. The patient's recovery was uneventful and he was discharged on post-operative day four without complications. CONCLUSION: Patients with broken sternal wires and an unstable sternum require careful evaluation and management as these may have potentially life-threatening complications if left untreated.


Subject(s)
Bone Wires , Cardiac Surgical Procedures , Lacerations , Pericardial Effusion , Thoracic Injuries , Humans , Male , Middle Aged , Bone Wires/adverse effects , Cardiac Surgical Procedures/adverse effects , Lacerations/etiology , Lacerations/surgery , Pericardial Effusion/etiology , Sternotomy/adverse effects , Sternum/surgery , Thoracic Injuries/etiology
13.
ASAIO J ; 69(11): 993-1000, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37678260

ABSTRACT

Traditional ice storage has been the historic standard for preserving donor's hearts. However, this approach provides variability in cooling, increasing risks of freezing injury. To date, no preservation technology has been reported to improve survival after transplantation. The Paragonix SherpaPak Cardiac Transport System (SCTS) is a controlled hypothermic technology clinically used since 2018. Real-world evidence on clinical benefits of SCTS compared to conventional ice cold storage (ICS) was evaluated. Between October 2015 and January 2022, 569 US adults receiving donor hearts preserved and transported either in SCTS (n = 255) or ICS (n = 314) were analyzed from the Global Utilization And Registry Database for Improved heArt preservatioN (GUARDIAN-Heart) registry. Propensity matching and a subgroup analysis of >240 minutes ischemic time were performed to evaluate comparative outcomes. Overall, the SCTS cohort had significantly lower rates of severe primary graft dysfunction (PGD) ( p = 0.03). When propensity matched, SCTS had improving 1-year survival ( p = 0.10), significantly lower rates of severe PGD ( p = 0.011), and lower overall post-transplant MCS utilization ( p = 0.098). For patients with ischemic times >4 hours, the SCTS cohort had reduced post-transplant MCS utilization ( p = 0.01), reduced incidence of severe PGD ( p = 0.005), and improved 30-day survival ( p = 0.02). A multivariate analysis of independent risk factors revealed that compared to SCTS, use of ice results in a 3.4-fold greater chance of severe PGD ( p = 0.014). Utilization of SCTS is associated with a trend toward increased post-transplant survival and significantly lower severe PGD and MCS utilization. These findings fundamentally challenge the decades-long status quo of transporting donor hearts using ice.


Subject(s)
Heart Transplantation , Tissue Donors , Adult , Humans , Heart Transplantation/adverse effects , Heart Transplantation/methods , Ice , Heart , Incidence , Retrospective Studies
14.
Circ Heart Fail ; 16(8): e010038, 2023 08.
Article in English | MEDLINE | ID: mdl-37345518

ABSTRACT

BACKGROUND: Information about health-related quality of life (HRQOL) among caregivers of older patients with heart failure who receive heart transplantation (HT) and mechanical circulatory support (MCS) is sparse. We describe differences and factors associated with change in HRQOL before and early post-surgery among caregivers of older heart failure patients who underwent 3 surgical therapies: HT with pretransplant MCS (HT MCS), HT without pretransplant MCS (HT non-MCS), and long-term MCS. METHODS: Caregivers of older patients (60-80 years) from 13 US sites completed the EQ-5D-3 L visual analog scale (0 [worst]-100 [best] imaginable health state) and dimensions before and 3 and 6 months post-surgery. Analyses included linear regression, t tests, and nonparametric tests. RESULTS: Among 227 caregivers (HT MCS=54, HT non-MCS=76, long-term MCS=97; median age 62.7 years, 30% male, 84% White, 83% spouse/partner), EQ-5D visual analog scale scores were high before (84.8±14.1) and at 3 (84.7±13.0) and 6 (83.9±14.7) months post-surgery, without significant differences among groups or changes over time. Patient pulmonary hypertension presurgery (ß=-13.72 [95% CI, -21.07 to -6.36]; P<0.001) and arrhythmia from 3 to 6 months post-operatively (ß=-14.22 [95% CI, -27.41 to -1.02]; P=0.035) were associated with the largest decrements in caregiver HRQOL; patient marital/partner status (ß=6.21 [95% CI, 1.34-11.08]; P=0.013) and presurgery coronary disease (ß=8.98 [95% CI, 4.07-13.89]; P<0.001) were associated with the largest improvements. CONCLUSIONS: Caregivers of older patients undergoing heart failure surgeries reported overall high HRQOL before and early post-surgery. Understanding factors associated with caregiver HRQOL may inform decision-making and support needs. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02568930.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Female , Humans , Male , Middle Aged , Caregivers , Heart Failure/surgery , Quality of Life , Aged , Aged, 80 and over
15.
N Engl J Med ; 388(23): 2121-2131, 2023 Jun 08.
Article in English | MEDLINE | ID: mdl-37285526

ABSTRACT

BACKGROUND: Data showing the efficacy and safety of the transplantation of hearts obtained from donors after circulatory death as compared with hearts obtained from donors after brain death are limited. METHODS: We conducted a randomized, noninferiority trial in which adult candidates for heart transplantation were assigned in a 3:1 ratio to receive a heart after the circulatory death of the donor or a heart from a donor after brain death if that heart was available first (circulatory-death group) or to receive only a heart that had been preserved with the use of traditional cold storage after the brain death of the donor (brain-death group). The primary end point was the risk-adjusted survival at 6 months in the as-treated circulatory-death group as compared with the brain-death group. The primary safety end point was serious adverse events associated with the heart graft at 30 days after transplantation. RESULTS: A total of 180 patients underwent transplantation; 90 (assigned to the circulatory-death group) received a heart donated after circulatory death and 90 (regardless of group assignment) received a heart donated after brain death. A total of 166 transplant recipients were included in the as-treated primary analysis (80 who received a heart from a circulatory-death donor and 86 who received a heart from a brain-death donor). The risk-adjusted 6-month survival in the as-treated population was 94% (95% confidence interval [CI], 88 to 99) among recipients of a heart from a circulatory-death donor, as compared with 90% (95% CI, 84 to 97) among recipients of a heart from a brain-death donor (least-squares mean difference, -3 percentage points; 90% CI, -10 to 3; P<0.001 for noninferiority [margin, 20 percentage points]). There were no substantial between-group differences in the mean per-patient number of serious adverse events associated with the heart graft at 30 days after transplantation. CONCLUSIONS: In this trial, risk-adjusted survival at 6 months after transplantation with a donor heart that had been reanimated and assessed with the use of extracorporeal nonischemic perfusion after circulatory death was not inferior to that after standard-care transplantation with a donor heart that had been preserved with the use of cold storage after brain death. (Funded by TransMedics; ClinicalTrials.gov number, NCT03831048.).


Subject(s)
Brain Death , Heart Transplantation , Tissue and Organ Procurement , Adult , Humans , Graft Survival , Organ Preservation , Tissue Donors , Death , Patient Safety
17.
Clin Appl Thromb Hemost ; 29: 10760296231166370, 2023.
Article in English | MEDLINE | ID: mdl-37069794

ABSTRACT

BACKGROUND: Heparin-induced thrombocytopenia (HIT) is a common differential diagnosis in cardiothoracic surgery. The latex immunoturbidimetric assay (LIA) is an enhanced immunoassay that has recently been introduced for the detection of total HIT immunoglobulin and retains a higher specificity of 95% compared to the enzyme-linked immunosorbent assay. OBJECTIVES: To investigate if a semiquantitative relationship exists between increasing LIA levels beyond the current positivity threshold and its correlation to positive serotonin release assay results in cardiothoracic surgery. METHODS: This was a multicenter, observational cohort of cardiothoracic surgery patients initiated on anticoagulation with heparin-based products. To conduct sensitivity and specificity analysis of LIA values, HIT positive was defined as a LIA value ≥1 unit/mL and HIT negative was defined as a LIA level <1 unit/mL. A receiver operating characteristic (ROC) analysis was utilized to evaluate the predictive performance of the LIA. RESULTS: At manufactures' cutoffs of ≥1.0 unit/mL, LIA sensitivity and specificity was 93.8% and 22%, respectively, yielding a false positive rate of 78%. At a higher cutoff of 4.5 units/mL, LIA sensitivity and specificity was 75% and 71%, respectively, yielding a false positive rate of 29% and an area under the ROC curve of 0.75 (P = .01; 95% confidence interval: 0.621-0.889). Bivalirudin was initiated in 84.6% of false positive LIA results. CONCLUSION: This study suggests that the diagnostic accuracy of the LIA can be optimized by increasing the LIA positivity threshold. Proposing a higher LIA cutoff, may mitigate unwarranted anticoagulation and bleeding outcomes.


Subject(s)
Latex , Thrombocytopenia , Humans , Latex/adverse effects , Immunoturbidimetry , Thrombocytopenia/chemically induced , Thrombocytopenia/diagnosis , Heparin/adverse effects , Enzyme-Linked Immunosorbent Assay/methods , Anticoagulants/adverse effects
18.
J Heart Lung Transplant ; 42(5): 553-557, 2023 05.
Article in English | MEDLINE | ID: mdl-36841643

ABSTRACT

A redesigned surgically implanted heart pump incorporates several design changes from the prior device generation, but no published comparative data demonstrate if these changes translate to improved outcomes. We retrospectively compared clinical characteristics and outcomes, drawn from an FDA-mandated QA database, for contemporary patients treated with the Impella 5.5 or Impella 5.0 for acute myocardial infarction complicated by cardiogenic shock (AMICS), cardiomyopathy, or postcardiotomy cardiogenic shock (PCCS). A total of 1238 patients at 290 US sites were included for analysis. Patients receiving the Impella 5.5 had significantly higher survival through explant (i.e., successfully weaned or bridged to heart replacement therapy) than those receiving the Impella 5.0 in all 3 settings: AMICS (70.5% vs 56.8%; p = 0.005), cardiomyopathy (88.1% vs 76.9%; p = 0.001), and PCCS (76.1% vs 55.7%; p = 0.003). Duration of support was significantly longer for Impella 5.5 patients with AMICS (9.2 vs 6.1 days; p = 0.008) and cardiomyopathy (10.7 vs 8.1 days; p < 0.001).


Subject(s)
Heart Failure , Heart-Assist Devices , Myocardial Infarction , Humans , Shock, Cardiogenic/etiology , Shock, Cardiogenic/surgery , Retrospective Studies , Treatment Outcome , Heart-Assist Devices/adverse effects , Heart Failure/complications , Heart Failure/surgery , Cardiotonic Agents
19.
ASAIO J ; 69(2): 174-182, 2023 02 01.
Article in English | MEDLINE | ID: mdl-35421002

ABSTRACT

The Jarvik 2000 bridge to transplant investigational device exemption study was a multicentered, prospective study of 150 UNOS status I patients implanted with the Jarvik 2000 between 2005 and 2012. During the study period, there were numerous modifications of the system that included converting from pin to cone bearings. Results were analyzed for three cohorts: total (n = 150), pin (n = 128), and cone (n = 22). Baseline demographics included age (52 ± 13), gender (79% male), size (BSA 1.98), and etiology (37% idiopathic dilated cardiomyopathy; 43% Ischemic). Seventy percent of patients were either INTERMACS 1 or 2. The primary endpoint-defined as successful transplantation or listing at 180 days (prespecified at 65%; 95% lower CI: 57%)-was successfully achieved for the total cohort (67.3%; 95% CI: 59.5%-74.3%; p = 0.006). In subgroup analysis of the more contemporary, cone-bearing group, the primary endpoint was met in 91% (95% CI: 72%-97.5%; p = 0.001). Compared with pin patients, cone-bearing patients had less hemolysis as well as decreased end-organ dysfunction. Functional and quality of life scores improved after implantation independent type of bearing. In conclusion, despite a particularly sick patient population, the Jarvik 2000 was shown to be effective in supporting the advanced HF patient.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Female , Humans , Male , Heart Failure/surgery , Prospective Studies , Quality of Life , Treatment Outcome , United States
20.
J Thorac Cardiovasc Surg ; 166(3): 851, 2023 09.
Article in English | MEDLINE | ID: mdl-35431035
SELECTION OF CITATIONS
SEARCH DETAIL
...