Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Control Release ; 330: 658-668, 2021 02 10.
Article in English | MEDLINE | ID: mdl-33347943

ABSTRACT

Long-acting antiretroviral implants could help protect high-risk individuals from HIV infection. We describe the design and testing of a long-acting reservoir subcutaneous implant capable of releasing cabotegravir for several months. We compressed cabotegravir and excipients into cylindrical pellets and heat-sealed them in tubing composed of hydrophilic poly(ether-urethane) -. The implants have a 47 mm lumen length, 3.6 mm outer diameter, and 200 µm wall thickness. Four cabotegravir pellets were sealed in the membrane, with a total drug loading of 274 ± 3 mg. In vivo, the implants released 348 ± 107 µg/day (median value per implant, N = 41) of cabotegravir in rhesus macaques. Five implants generated an average cabotegravir plasma concentration of 373 ng/ml in rhesus macaques. The non-human primates tolerated the implant without gross pathology or microscopic signs of histopathology compared to placebo implants. Cabotegravir plasma levels in macaques dropped below detectable levels within two weeks after the removal of the implants.


Subject(s)
Anti-HIV Agents , HIV Infections , HIV-1 , Animals , Anti-HIV Agents/therapeutic use , HIV Infections/drug therapy , HIV Infections/prevention & control , Macaca mulatta , Pyridones
2.
Pharm Res ; 37(4): 83, 2020 Apr 15.
Article in English | MEDLINE | ID: mdl-32296951

ABSTRACT

PURPOSE: Sexual transmission of HIV has been clinically proven to be preventable with a once-daily oral tablet; however, missed doses dramatically increase the risk of HIV infection. Long-acting subcutaneous implants do not allow the user to miss a dose. A desirable long-acting drug-eluting implant can deliver a constant amount of drug, adjust the delivered dose, and be readily manufactured. We present a long-acting, subcutaneous implant design composed of tenofovir alafenamide hemifumarate (TAF) pellets loaded in a sealed polyether urethane tube for the prevention of HIV transmission. METHODS: Implants were prepared with pressed drug pellets and extruded polyurethane tubing. In vitro release rate of implants using different pellet formulations, rate-controlling membranes, and geometries were measured. RESULTS: Tenofovir alafenamide release appeared to be governed by a pseudo-steady state and followed a mass transport model of release from a cylindrical drug reservoir. Implant seal integrity was tested and confirmed using mechanical testing. The inclusion of sodium chloride in the pellet increased the release rate and reduced initial lag. The release was sustained for 100 days. CONCLUSIONS: The release rate of tenofovir alafenamide mechanistically varied with geometry and rate controlling membrane composition. The polyether urethane implant presented herein is modular and tunable to adjust the release rate and duration of the TAF release.


Subject(s)
Anti-HIV Agents/administration & dosage , Drug Delivery Systems/instrumentation , Drug Implants/metabolism , Equipment Design , Tenofovir/administration & dosage , Drug Compounding/methods , Drug Delivery Systems/methods , Drug Delivery Systems/standards , Drug Implants/standards , Drug Liberation , Humans , Injections, Subcutaneous , Models, Theoretical
3.
Article in English | MEDLINE | ID: mdl-31871073

ABSTRACT

We describe the in vitro and in vivo evaluation of a subcutaneous reservoir implant delivering tenofovir alafenamide hemifumarate (TAF) for the prevention of HIV infection. These long-acting reservoir implants were able to deliver antiretroviral drug for over 90 days in vitro and in vivo We evaluated the implants for implantation site histopathology and pharmacokinetics in plasma and tissues for up to 12 weeks in New Zealand White rabbit and rhesus macaque models. A dose-ranging study in rabbits demonstrated dose-dependent pharmacokinetics and local inflammation up to severe necrosis around the active implants. The matched placebos showed normal wound healing and fibrous tissue encapsulation of the implant. We designed a second implant with a lower release rate and flux of TAF and achieved a median cellular level of tenofovir diphosphate of 42 fmol per 106 rhesus macaque peripheral blood mononuclear cells at a TAF dose of 10 µg/kg/day. This dose and flux of TAF also resulted in adverse local inflammation and necrosis near the implant in rhesus macaques. The level of inflammation in the primates was markedly lower in the placebo group than in the active-implant group. The histological inflammatory response to the TAF implant at 4 and 12 weeks in primates was graded as a severe reaction. Thus, while we were able to achieve a sustained target dose, we observed an unacceptable inflammatory response locally at the implant tissue interface.


Subject(s)
Adenine/analogs & derivatives , Anti-HIV Agents/adverse effects , Delayed-Action Preparations , Drug Implants/administration & dosage , Necrosis/chemically induced , Polyurethanes/administration & dosage , Adenine/adverse effects , Adenine/blood , Adenine/pharmacokinetics , Alanine , Animals , Anti-HIV Agents/blood , Anti-HIV Agents/pharmacokinetics , Female , Fumarates/chemistry , HIV Infections/prevention & control , Humans , Inflammation , Macaca mulatta , Male , Necrosis/pathology , Rabbits , Subcutaneous Tissue/surgery , Tenofovir/analogs & derivatives
SELECTION OF CITATIONS
SEARCH DETAIL
...