Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Gait Posture ; 27(2): 189-95, 2008 Feb.
Article in English | MEDLINE | ID: mdl-17466520

ABSTRACT

The conventional rigid spinal orthosis and the flexible spinal orthosis, SpineCor, have different treatment principles in the management of adolescent idiopathic scoliosis (AIS). These may influence the patients' gait pattern and clinical outcome. In this study, gait analysis on patients with AIS undergoing these two orthotic interventions were conducted. The patients' lower limb kinematic and kinetic data during level walking were collected using a motion analysis system and two force platforms in four test conditions: pre-intervention, having used the orthosis for 1 month and 1 year (in and out of the orthosis). Twenty-one subjects were randomly assigned to the rigid spinal orthosis group (10 subjects) and the SpineCor group (11 subjects). Neither group showed gait asymmetry when comparing the convex and concave sides in the four test conditions. However, significant reduction in the range of motion of the pelvis and hip joints in the coronal plane were found. Although patients with AIS undergoing these two orthotic interventions showed significant changes in walking pattern within the study period, their long-term effect on gait and function requires further investigation through long-term prospective studies.


Subject(s)
Braces , Scoliosis/physiopathology , Scoliosis/rehabilitation , Adolescent , Analysis of Variance , Biomechanical Phenomena , Child , Female , Humans
2.
Prosthet Orthot Int ; 30(2): 114-28, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16990222

ABSTRACT

A high degree of gait symmetry is characteristic of healthy gait. The aim of this study is to examine the symmetry of various gait parameters in subjects with unilateral trans-tibial amputation over a range of acceptable anteroposterior translational and tilt alignments, and further to examine if a consistent alignment of highest symmetry can be found. Acceptable alignments were determined by bench, static and dynamic testing on level and non-level surfaces. A total of 15 kinetic and kinematic parameters were then measured in the seven subjects participating in this study. Results indicate that some parameters show consistently higher symmetries, particularly the vertical ground reaction force parameters and the stance duration, step length and time to full knee flexion during the swing phase. Symmetries in other parameters such as knee flexion at loading response, acceleration impulse, and peak anteroposterior propulsive force seem to have little relevance in determining whether the gait pattern for that prosthetic alignment is acceptable or not. While analysis of the symmetry of more relevant gait parameters may assist the prosthetist in consistently and objectively identifying a most symmetrical alignment within the acceptable range, further clinical study is required before any conclusions can be drawn regarding evaluation of symmetry as a tool in defining any optimum alignment.


Subject(s)
Amputation, Surgical , Artificial Limbs , Gait/physiology , Prosthesis Fitting , Tibia/surgery , Adult , Biomechanical Phenomena , Female , Humans , Male , Middle Aged
3.
J Rehabil Res Dev ; 38(1): 1-6, 2001.
Article in English | MEDLINE | ID: mdl-11322461

ABSTRACT

Despite the fact that non-level walking is known to be important for prosthesis fitting, its clinical significance has not been investigated. In this study, the acceptable prosthesis alignment ranges of six subjects with transtibial amputation on level and non-level walking were determined and compared. With the aid of a recently developed alignment jig, prosthesis fitting was performed for each subject with varied anterior-posterior (AP) alignments. Conventional assessments and the subjects' comment were used to determine whether the alignment was acceptable or not. The results showed that the acceptable alignment range for non-level walking consistently fell within and was significantly smaller than that for level walking with p<0.05. It was evident that non-level walking is important for better approximation of optimum alignment and should be included in routine prosthesis fitting.


Subject(s)
Artificial Limbs , Prosthesis Fitting , Walking/physiology , Adult , Amputation, Surgical , Female , Humans , Leg , Male , Middle Aged , Tibia/surgery
4.
Prosthet Orthot Int ; 23(3): 225-30, 1999 Dec.
Article in English | MEDLINE | ID: mdl-10890597

ABSTRACT

Clinically, it is hard to achieve and reproduce prosthesis alignment at will during daily prosthesis fitting. A new alignment jig was designed and developed to facilitate quantification and prescription of prosthesis alignment for patellar-tendon-bearing (PTB) trans-tibial prostheses. The alignment jig provided instantaneous readings of the three-dimensional orientation and position of the socket relative to the prosthetic foot in standardised units. The inter- and intra-tester errors of the alignment jig in measuring prosthesis alignment were evaluated and demonstrated to have good reliability. The alignment jig was recommended to be used clinically after the conventional dynamic alignment procedure to document the prosthesis alignment. Further application of the alignment jig for systematic evaluation of the effects of prosthesis alignment on gait for trans-tibial amputees is suggested.


Subject(s)
Artificial Limbs , Prosthesis Design/instrumentation , Humans , Leg
SELECTION OF CITATIONS
SEARCH DETAIL
...