Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Magn Reson Imaging ; 36(3): 704-13, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22645046

ABSTRACT

PURPOSE: To establish the minimum dose required for detection of renal artery stenosis using high temporal resolution, contrast enhanced MR angiography (MRA) in a porcine model. MATERIALS AND METHODS: Surgically created renal artery stenoses were imaged with 3 Tesla MR and digital subtraction angiography (DSA) in 12 swine in this IACUC approved protocol. Gadobutrol was injected intravenously at doses of 0.5, 1, 2, and 4 mL for time-resolved MRA (1.5 × 1.5 mm(2) spatial resolution). Region of interest analysis was performed together with stenosis assessment and qualitative evaluation by two blinded readers. RESULTS: Mean signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were statistically significantly less with the 0.5-mL protocol (P < 0.001). There were no statistically significant differences among the other evaluated doses. Both readers found 10/12 cases with the 0.5-mL protocol to be of inadequate diagnostic quality (κ = 1.0). All other scans were found to be adequate for diagnosis. Accuracies in distinguishing between mild/insignificant (<50%) and higher grade stenoses (>50%) were comparable among the higher-dose protocols (sensitivities 73-93%, specificities 62-100%). CONCLUSION: Renal artery stenosis can be assessed with very low doses (~0.025 mmol/kg bodyweight) of a high concentration, high relaxivity gadolinium chelate formulation in a swine model, results which are promising with respect to limiting exposure to gadolinium based contrast agents.


Subject(s)
Algorithms , Angiography, Digital Subtraction , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Organometallic Compounds/administration & dosage , Renal Artery Obstruction/diagnosis , Animals , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Female , Image Enhancement/methods , Male , Reproducibility of Results , Sensitivity and Specificity , Swine
2.
Breast J ; 17(2): 187-90, 2011.
Article in English | MEDLINE | ID: mdl-21306469

ABSTRACT

Our purpose was to evaluate and compare the imaging sequela and complications of accelerated partial breast irradiation (APBI) with those occurring in patients treated with standard external beam therapy. Patient selection included those who met the criteria for possible ABPI: age 45 or older; cancer stage T1N0M0 or ductal carcinoma in situ 3 cm or less, and negative surgical margins. One hundred and ninety seven had complete records and films available for review. Ninety-seven (49%) were treated with APBI (MammoSite) and 100(51%) were treated with external beam. Image findings for APBI versus external beam were: distortion 90(93%) versus 83(83%), seroma 67(69%) versus 7(7%), skin edema 52(54%) versus 47(47%), increased stroma 75(77%) versus 66(66%), calcifications 10(10%) versus 6(6%), and fat necrosis 12(12%) versus 6(6%). For APBI, skin and stromal edema was more commonly focal. At imaging, the seroma rate was statistically and significantly different between the two treatment modes (p < 0.0001). For patients treated with APBI, seroma formation was not related to balloon size and only weakly related to lumpectomy cavity size. The complication rate was significantly higher for those treated with APBI (36 versus 20%) and the types and treatment of complications differed. There were three recurrences among the APBI group and none among those treated with external beam radiation.


Subject(s)
Breast Neoplasms/pathology , Breast Neoplasms/radiotherapy , Carcinoma, Ductal, Breast/pathology , Carcinoma, Ductal, Breast/radiotherapy , Carcinoma, Intraductal, Noninfiltrating/radiotherapy , Breast Neoplasms/diagnostic imaging , Calcinosis/etiology , Carcinoma, Ductal, Breast/diagnostic imaging , Edema/etiology , Fat Necrosis/etiology , Female , Humans , Mammography , Middle Aged , Neoplasm Invasiveness , Neoplasm Recurrence, Local , Neoplasm Staging , Radiotherapy/adverse effects , Radiotherapy/methods , Seroma/etiology , Single-Blind Method , Skin Diseases/etiology
4.
Emerg Radiol ; 16(2): 121-8, 2009 Mar.
Article in English | MEDLINE | ID: mdl-18677520

ABSTRACT

The objective of this pictorial essay is to review uncommon abdominal hernias, many of which present to the Emergency Department with abdominal pain. These hernias may be congenital, post-traumatic, or iatrogenic in origin. They may present as an acute (surgical) abdomen without localizing signs or symptoms. They may present with an obvious antecedent event such as motor vehicle trauma or simply present as an incidental finding. Multi-detector computed tomography is currently the study of choice to diagnose abdominal hernia and to evaluate the possible complications such as small bowel obstruction and/or strangulation. This modality can delineate a "zone of transition" (abnormally dilated bowel transitioning to normal or decreased bowel caliber) or identify the involved anatomy. It can also suggest compromised blood supply.


Subject(s)
Hernia, Abdominal/diagnostic imaging , Tomography, X-Ray Computed , Acute Disease , Adult , Aged , Aged, 80 and over , Emergency Service, Hospital , Female , Hernia, Diaphragmatic/diagnostic imaging , Hernia, Inguinal/diagnostic imaging , Hernia, Obturator , Humans , Incidental Findings , Infant, Newborn , Male , Sacrococcygeal Region
5.
Eur Radiol ; 18(10): 2095-101, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18463873

ABSTRACT

The ability of fast, parallel-imaging-based cine magnetic resonance (MR) to monitor global cardiac function in longitudinal exams at 3 Tesla was evaluated. Seventeen patients with chronic cardiac disease underwent serial cine MR imaging exams (n=3) at 3 Tesla. Data were acquired in short-axis orientation using cine steady-state free precession (SSFP) with a spatial resolution of 2.5 x 1.9 mm(2) at 45 ms temporal resolution. Multislice imaging (three slices/breath-hold) was performed using TSENSE acceleration (R=3) and standard single-slice cine (non-TSENSE) was performed at identical locations in consecutive breath-holds. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and myocardial mass (MM) of both cine approaches were compared for individual time-points as well as for longitudinal comparison. TSENSE-cine did not show significant differences for EDV (2.6 ml; P=0.79), ESV (2.2 ml; P=0.81), EF (-0.3%; P=0.95) and MM (2.4 g; P=0.72) in comparison with non-TSENSE. Longitudinal ANOVA analysis did not reveal significant differences for any parameter, neither for non-TSENSE data (all P>0.7) nor for TSENSE data (all P>0.9). Multifactorial ANOVA showed non-significant differences (all P>0.7) at comparable data variances. Data acquisition was significantly shortened using TSENSE. Threefold accelerated multislice cine at 3 Tesla allows accurate assessment of volumetric LV data and accurate longitudinal monitoring of global LV function at a substantially shorter overall examination time.


Subject(s)
Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging, Cine/methods , Ventricular Dysfunction, Left/diagnosis , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Longitudinal Studies , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Stroke Volume
6.
Eur Radiol ; 17(1): 73-80, 2007 Jan.
Article in English | MEDLINE | ID: mdl-16633789

ABSTRACT

The purpose of our study was to evaluate the accuracy of a multislice cine magnetic resonance imaging (MRI) technique with parallel imaging in regard to global and regional left ventricular function. Forty-two individuals underwent cine MRI on a 1.5-tesla scanner. Cine MRI used a steady-state free precession technique and was performed as a single-slice technique (nonTSENSE cine) and an accelerated multislice technique (TSENSE cine) with five slices per breath-hold. End diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) were evaluated for all data sets and in regard to regional wall motion and regional wall motion analysis, and quantitative regional wall thickness and systolic thickening were also assessed. EDV, ESV, and EF based on TSENSE cine showed excellent correlation to the nonTSENSE cine approach (all r(2)=0.99, P<0.001). While EDV evaluations showed a small underestimation for TSENSE cine, ESV and EF showed accurate results compared with nonTSENSE cine. Both readers showed good agreement (kappa=0.72) in regional wall motion assessment comparing both techniques. Data acquisition for the multislice approach was significantly shorter ( approximately 75%) that in single-slice cine. We conclude that accurate evaluation of regional wall motion and left ventricular EF is possible using accelerated multislice cine MR with high spatial and temporal resolution.


Subject(s)
Heart Diseases/physiopathology , Magnetic Resonance Imaging, Cine/methods , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Respiration
SELECTION OF CITATIONS
SEARCH DETAIL
...