Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Dent J (Basel) ; 12(6)2024 May 23.
Article in English | MEDLINE | ID: mdl-38920857

ABSTRACT

Sleep bruxism, characterized by involuntary grinding or clenching of teeth during sleep, poses significant challenges in management due to its potential to induce temporomandibular joint disorders (TMDs) and other related symptoms. The use of Botulinum toxin Type A (BoNT-A), also known as Botox®, has been proposed as a therapeutic intervention. This systematic review aims to evaluate the efficacy and safety of BoNT-A in the management of sleep bruxism, focusing on pain reduction, improvement in jaw function, reduction in bruxism episodes, and the incidence of adverse effects. An exhaustive search was conducted across PubMed, Scopus, and Embase databases up to January 2024, adhering to the PRISMA guidelines. Nine randomized clinical trials (RCTs) involving 137 participants were analyzed for efficacy and safety outcomes. The studies demonstrated a significant reduction in mean pain scores (from 7.1 to 0.2 at 6 months and 1 year post-treatment in one study) and a notable decrease in the number of bruxism events (from 4.97/h to 1.70/h in the BoNT-A group in another study). Additionally, improvements were observed in jaw stiffness and total sleep time. Adverse effects varied but were generally mild and transient, including injection site pain in 20% of participants in one study and cosmetic changes in smile in 15.4% of patients in another. These findings suggest that BoNT-A injections may provide some benefits for treating nocturnal bruxism, potentially reducing TMD symptoms like pain and improving jaw function. However, these findings are preliminary due to variability in study designs and the absence of detailed statistical analysis.

2.
Polymers (Basel) ; 16(7)2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38611252

ABSTRACT

The impression materials utilized today in dental medicine offer a good reproducibility and are easily accepted by patients. However, because they are polymer-based, they have issues regarding their dimensional stability. In this respect, the present work proposes a new type of dental impression, which is reinforced with rigid mouthguards. The aim of the study is to test the performances of such new impressions by comparing them to conventional ones-from this critical point of view, of the dimensional stability. Three types of polymeric materials were considered for both types of impressions: alginate, condensation silicone, and addition silicone. In order to obtain the new type of impressions, a manufacturing technique was developed, comprising the following phases: (i) conventional impressions were made; (ii) a plaster model was duplicated, and 15 rigid mouthguards were obtained; (iii) they were inserted in the impression technique, with each mouthguard positioned on the cast before the high-consistency material was inserted in the tray and the practitioner took the impression; (iv) the mouthguard remained in the tray and the low-viscosity material was inserted over the mouthguard; (v) the impression was positioned on the model, and after the material hardened, the mouthguard-reinforced impression was analyzed. In the evaluation of the dimensional stability, rigorous statistical analysis was essential to discern the performance differences between conventional and mouthguard-reinforced dental impressions. Statistical analyses employed non-parametric Mann-Whitney U tests because of the non-normal distribution of the data. They indicated a statistically significant improvement in the dimensional stability of addition silicone impressions when reinforced with mouthguards (p < 0.05), showcasing superior performance over conventional methods. Conversely, alginate and condensation silicone reinforced impressions did not exhibit the same level of stability improvement, suggesting the need for further optimization of these materials. In conclusion, from the three considered elastomers, addition silicone was found to be the prime candidate for high-precision dental impressions, with the potential to improve their quality from conventional impressions by utilizing the proposed reinforcing technique.

3.
Materials (Basel) ; 16(10)2023 May 12.
Article in English | MEDLINE | ID: mdl-37241322

ABSTRACT

(1) Background: Aesthetic dentistry has become one of the most dynamic fields in modern dental medicine. Ceramic veneers represent the most appropriate prosthetic restorations for smile enhancement, due to their minimal invasiveness and highly natural appearance. For long-term clinical success, accurate design of both tooth preparation and ceramic veneers is of paramount importance. The aims of this in vitro study were to assess the stress in anterior teeth restored with Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) ceramic veneers and compare the resistance to detachment and the fracture of ceramic veneers prepared using two different designs. (2) Methods: Sixteen lithium disilicate ceramic veneers were designed and milled using the CAD-CAM technology and divided into two groups according to the preparations (n = 8): Group 1, conventional (CO), with linear marginal contour and Group 2, crenelated (CR), the latter with our novel (patented) sinusoidal marginal design. All samples were bonded to anterior natural teeth. The mechanical resistance to detachment and fracture was investigated by applying bending forces on the incisal margin of the veneers in order to determine which type of preparation leads to better adhesion. An analytic method was employed, as well, and the results of the two approaches were compared. (3) Results: The mean values of the maximum force recorded at the veneer detachment were 78.82 ± 16.55 N for the CO group and 90.20 ± 29.81 N for the CR group. The relative increase, equal to 14.43%, demonstrated that the novel CR tooth preparation provided higher adhesive joints. In order to determine the stress distribution within the adhesive layer, a finite element analysis (FEA) was performed. The statistical t-test showed that the mean value of the maximum normal stresses is higher for the CR-type preparations. (4) Conclusions: The patented CR veneers represent a practical solution to augment the adhesion and mechanical properties of ceramic veneers. The obtained results demonstrated that CR adhesive joints triggered higher mechanical and adhesive forces, which subsequently led to a higher resistance to detachment and fracture.

4.
Medicina (Kaunas) ; 59(2)2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36837500

ABSTRACT

Background and Objectives: Implant rehabilitation of complete edentulous arches has become more and more popular because of the increased access of the population to this type of treatment. Furthermore, the development of new rehabilitation procedures can be applied in most clinical cases, including in those with severe atrophy. Hence, this study aimed to assess the functional changes that can occur in the stomatognathic system after implant rehabilitation procedures. Materials and Methods: A total of 63 patients were accepted in the study. They were divided into a first control (dentate) group (CG) and a second study group (edentulous, SG). For the latter, 30 patients received 204 two-stage implants immediately loaded with provisional prostheses. Surface electromyography (EMG) was assessed at the time of prostheses fixation, while for some patients it was applied six months after the fixation of the fixed prostheses, as well. These supplemental investigated patients formed a third, follow-up study group (FSG). All assessments were performed during the processes of clenching and mastication. The obtained data of the two study groups, SG and FSG, were compared with those of the control group, CG. Results: No statistical differences were found in the electrical muscular activity between the study and control groups during both clenching and mastication (p > 0.05). In addition, there were no differences within the same study group, both initially and after 6 months. The only changes were noticed between static and dynamic values for the right masseter muscle in the follow-up group FSG (p = 0.008). Deviations of the overlapping coefficients were similar for all groups (p = 0.086): for CG, 20.5%, median 11.1 (min. 0, max. 104); for SG, 21.4%, median 12.2 (min. 0, max. 103); for FSG, 36.1%, median 26.9 (min. 0, max. 160). This revealed no neuromuscular adaption to the prostheses. Conclusions: Implant-prosthetic rehabilitation led to an EMG activity that was similar to that of dentate patients immediately after the placement of the fixed implant-supported prostheses. Moreover, the measured values did not change after six months of functioning for all evaluated parameters. This may point to an immediate restoration of the muscle contraction capacity, without the necessity of adaptation over time. The study serves as an argument for the application and reliability of the immediate fixed implant-supported prostheses from the perspective of muscle adaptation and functioning.


Subject(s)
Masseter Muscle , Mouth, Edentulous , Humans , Follow-Up Studies , Reproducibility of Results , Mouth, Edentulous/rehabilitation , Prostheses and Implants , Treatment Outcome
5.
Medicina (Kaunas) ; 58(9)2022 Sep 18.
Article in English | MEDLINE | ID: mdl-36143980

ABSTRACT

Background and Objectives: The excessive use of smartphones for various tasks led to a new adverse postural phenomenon called text neck. The aim of this study was to investigate the effect of the text neck posture (TNP) on static occlusion by using the T-Scan III occlusal diagnostic system. Materials and Methods: Nineteen subjects (aged 20 to 24 years) were considered for this research. They had normal values for anterior overbite and overjet, Angle Class I occlusion, no posterior crossbite, and no signs or symptoms of cervical or temporo-mandibular disorders. Occlusal registrations were performed with the T-Scan III system in a normal, neutral head posture (NHP), as well as in the TNP. The investigated parameters were: occlusion time (OT), asymmetry index of the occlusal force (AOF), percent of the maximum movie force (%MMF), and the time elapsed from the last occlusal contact until the maximum intercuspation (MAT-OTB). The last three parameters were analyzed in the maximum area frame (MA) of the registrations. For the statistical analysis of the recorded data, the Wilcoxon Signed Ranks test and the Spearman's correlation coefficient were used. Results: The following values were obtained in NHP and in TNP: for AOF, 14.88 ± 10.39% and 18.04 ± 12.83%, respectively; for OT, 1.34 ± 1.84 s and 1.32 ± 1.8 s, respectively; for the %MMF, 97.5 ± 2.83% and 96.31 ± 3.17%, respectively; for MAT-OTB, 2.08 ± 1.82 s and 1.45 ± 2.3 s, respectively. There were no statistically significant differences between the static occlusal parameters measured in NHP and those in TNP. However, the high values of the AOF and OT in NHP revealed an imbalance of the occlusal force distribution between the right and left side in maximum intercuspation (MI), as well as a lack of simultaneity of static occlusal contacts. Furthermore, there was a significant, direct, and strong correlation between OT and AOF in NHP. Conclusions: The NHP should not be used as the starting position in TNP simulations in T-Scan studies, so as to avoid statistically insignificant differences between static occlusion in NHP and TNP. The healthy standing subjects, with normal occlusal relationships from the clinical point of view, revealed an occlusal instability in NHP when examined with the T-Scan.


Subject(s)
Malocclusion , Temporomandibular Joint Disorders , Bite Force , Chest Pain , Dental Occlusion , Humans , Posture
6.
Materials (Basel) ; 15(14)2022 Jul 14.
Article in English | MEDLINE | ID: mdl-35888366

ABSTRACT

Bone scaffolds must fulfil numerous and sometimes contradictory characteristics: biocompatibility, bioactivity, high porosity, and appropriate mechanical strength. To tackle some of these issues, this study has several aims for the development of such scaffolds for dentistry applications: (i) to utilize appropriate materials (ceramics and sponges) and to introduce a novel, potentially performant ceramic material; (ii) to characterize the obtained scaffolds by using a range of methods; (iii) to compare and to correlate the assessment results with the scope to validate them reciprocally. There are two commercially available dental ceramics (i.e., Ceramco iC Natural Enamel (E) and Ceramco iC Natural Dentine (D), (DeguDent GmbH, Hanau-Wolfgang, Deutschland)) that are considered, as well as a new-developed porcelain (ceramic C). To obtain porous structures of scaffolds, each ceramic is introduced in two different sponges: a denser one, green (G) and a less dense one, blue (B). A total of 60 samples are manufactured and divided in six study groups, obtained by combining the above materials: GE, BE, GD, BD, GC, and BC (where the first letter represents the sponge type and the second one the utilized ceramic). Several methods are applied to characterize their chemical composition, as well as their macro- and micro-porosity: X-ray Diffraction (XRD), apparent porosity measurements, scanning electronic microscopy (SEM), and confocal microscopy (CM). The latter two methods image the inner (porous) and the outer/cortical (denser) areas of the samples. The results show a good porosity (i.e., dimensions and uniformity of pores) of around 65% for the final group BC, with satisfactory values of around 51% for BD and GC. A certain correlation is made between SEM, CM, and the apparent porosity results. The biocompatibility of the new ceramic C is demonstrated. Finally, a necessary trade-off is made with the mechanical strength of the obtained scaffolds, which was also evaluated. From this point of view, Group BD has the highest compressive strength of around 4 MPa, while Group BC comes second, with around 2 MPa. This trade-off between porosity and mechanical strength suggests a choice between Groups BC and BD, which are the best with regard to the porosity and mechanical strength criterium, respectively.

7.
Materials (Basel) ; 15(9)2022 Apr 21.
Article in English | MEDLINE | ID: mdl-35591361

ABSTRACT

Maintaining the original trajectory of the root canal is a major challenge in endodontic therapy, especially in narrow and curved root canals. The present study aims to assess the shaping capacity of three endodontic systems made of different nickel−titanium alloys on simulated curved root canals. Thirty-six endodontic resin blocks (Ref. V040245, VDW) divided into three groups, each of twelve blocks (n = 12), were shaped, photographed, and analyzed: Group 1-Protaper Gold (PTG) (Dentsply Maillefer, Ballaigues, Switzerland) F2 25/08; Group 2-Reciproc Blue (RB), RB 25/08 (VDW, Munich, Germany); Group 3-WaveOne Gold (WOG) (Dentsply Maillefer), WOG 25/07. Each block was standardized and photographed before and after shaping in the same position, with the foramen oriented to the left. Post-shaping images were superimposed onto the initial ones. Thirteen measurement points were used for evaluation, spaced with 1 mm distance from one another, from level 0, apical foramen, to level 12, coronal orifice. The amount of removed resin from inner (X1) and outer (X2) walls, the direction of transportation (X1 − X2), and the centering ability (X1 − X2)/Y were measured, calculated, and comparatively analyzed. Statistical differences (p < 0.05) were observed between the shaping capacity of the considered systems in the middle and coronal thirds. PTG had a better centering ability than WOG and RB in the coronal third, while RB was more centered in the middle third in comparison to both WOG and PTG. In the apical third, the centering capacity of WOG was higher, without being statistically significant. WOG 25/07 and PTG 25/08 tend to cut more on the inner wall of the root canals, and RB 25/08 on the external one.

8.
J Clin Med ; 11(3)2022 Jan 28.
Article in English | MEDLINE | ID: mdl-35160127

ABSTRACT

This systematic review and meta-analysis aimed at assessing the diagnostic accuracy of emerging technologies, such as laser fluorescence (LF), transillumination, light-emitting diode devices, optical coherence tomography (OCT), alternating current impedance spectroscopy, fluorescence cameras (FC), photo-thermal radiometry, and modulated luminescence technology. In vivo and in vitro results of such non-ionizing, non-invasive, and non-destructive methods' effectiveness in non-cavitated dentin caries detection are sometimes ambiguous. Following the PRISMA guidelines, 34 relevant research articles published between 2011-2021 were selected. The risk of bias was assessed with a tool tailored for caries diagnostic studies, and subsequent quantitative uni- and bi-variate meta-analysis was carried out in separate sub-groups according to the investigated surface (occlusal/proximal) and study setting (in vivo/in vitro). In spite of the high heterogeneity across the review groups, in vitro studies on LF and FC proved a good diagnostic ability for the occlusal surface, with area under the curve (AUC) of 0.803 (11 studies) and 0.845 (five studies), respectively. OCT studies reported an outstanding performance with an overall AUC = 0.945 (four studies). Promising technologies, such as OCT or FC VistaProof, still need well-designed and well-powered studies to accrue experimental and clinical data for conclusive medical evidence, especially for the proximal surface. Registration: INPLASY202210097.

9.
J Clin Med ; 10(20)2021 Oct 14.
Article in English | MEDLINE | ID: mdl-34682841

ABSTRACT

BACKGROUND AND OBJECTIVES: The aim of this study is to demonstrate the increased efficiency achieved by dental practitioners when carrying out an ex vivo training process on 3D-printed maxillaries before performing in vivo surgery. MATERIALS AND METHODS: This developed ex vivo procedure comprises the following phases: (i) scanning the area of interest for surgery; (ii) obtaining a 3D virtual model of this area using Cone Beam Computed Tomography (CBCT); (iii) obtaining a 3D-printed model (based on the virtual one), on which (iv) the dental practitioner simulates/rehearses ex vivo (most of) the surgery protocol; (v) assess with a new CBCT the 3D model after simulation. The technical steps of sinus augmentation and implant insertion could be performed on the corresponding 3D-printed hemi-maxillaries prior to the real in vivo surgery. Two study groups were considered, with forty patients divided as follows: Group 1 comprises twenty patients on which the developed simulation and rehearsal procedure was applied; Group 2 is a control one which comprises twenty patients on which similar surgery was performed without this procedure (considered in order to compare operative times without and with rehearsals). RESULTS: Following the ex vivo training/rehearsal, an optimal surgery protocol was developed for each considered case. The results of the surgery on patients were compared with the results obtained after rehearsals on 3D-printed models. The performed quantitative assessment proved that, using the proposed training procedure, the results of the in vivo surgery are not significantly different (p = 0.089) with regard to the ex vivo simulation for both the mezio-distal position of the implant and the distance from the ridge margin to sinus window. On the contrary, the operative time of Group 1 was reduced significantly (p = 0.001), with an average of 20% with regard to in vivo procedures performed without rehearsals (on the control Group 2). CONCLUSIONS: The study demonstrated that the use of 3D-printed models can be beneficial to dental surgeon practitioners, as well as to students who must be trained before performing clinical treatments.

10.
Medicina (Kaunas) ; 57(9)2021 Aug 29.
Article in English | MEDLINE | ID: mdl-34577824

ABSTRACT

Background and Objectives: The aim of the present study is to compare the efficacy of three root canal preparation systems in the shaping of 3D-printed root canal replicas of single rooted teeth. Materials and Methods: Sixty 3D-printed root canal replicas were produced and divided into three groups, each consisting of twenty samples. Each group was shaped with a different instrument: Reciproc Blue R25/08 (VDW GmbH, Munich, Gemany), WaveOne Gold Primary 25/07 (Dentsply Sirona, Ballaigues, Switzerland), and ProTaper Gold F2 25/08 (Denstply Sirona). To ensure the reproducibility of pre- and post-operative CBCT images of the root canals, the endodontic printed replicas were placed in a mould of silicon impression material. A cone-beam computed tomography (CBCT) software was used to compare pre- and post-instrumentation images collected at three levels of the root canal length: 3, 6, and 9 mm from the apical foramen. The amount of transportation, centring ability, and curvature angle after shaping were evaluated for each system. The results were statistically analysed and compared using one-way analysis of variance (ANOVA). Results: Regarding the transportation of the root canal after shaping, significant differences between groups at 3 mm (p = 0.010721) and 6 mm (p = 0.000046) were recorded in the mesio-distal direction, while in the bucco-lingual significant differences were only observed at 6 mm (p = 0.000554). Reciproc Blue removed more dentin from the mesial and buccal wall of the root canal. When evaluating the centring ability of the three systems, significant differences were observed between the groups at the level of 9 mm (p = 0.037258) in the mesio-distal direction, and at the level of 6 mm (p = 0.038197) in the bucco-lingual direction. Significant differences of the canal curvature angle after shaping were also observed between groups (p = 0.000001). Reciproc Blue straightened the curvature the most, while ProTaper Gold the least. Conclusions: All systems produced minor root canal transportation. No instrument was able to achieve a perfect centring preparation of the root canal. All systems produced a small degree of root canal straightening.


Subject(s)
Nickel , Titanium , Cone-Beam Computed Tomography , Equipment Design , Humans , Printing, Three-Dimensional , Reproducibility of Results
11.
Exp Ther Med ; 22(3): 992, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34345274

ABSTRACT

Optical coherence tomography (OCT) is a non-invasive, non-radioactive optical diagnostic method based on low-coherence interferometry, which achieves images with different orientation. In dentistry, its major advantage is represented by the localization and characterization of the smallest defects in hard dental tissues, dental materials and of the smallest details in dental anatomy (supplementary canals, recesses, isthmuses, or intra-radicular connections). The aim of the present in vitro study was to evaluate using c-scan en-face optical coherence tomography, the optical opacity, and the distribution inside the root canal lumen of several extracted human teeth of silver and gold nanoparticles from special irrigating solutions used in endodontic treatment. Twelve root canals from 5 human teeth were instrumented using the ProTaper Universal system after initial negotiation with hand K-files ISO no. 10 and rotary nickel-titanium PathFile instruments. An initial c-scan OCT analysis was performed for each sample to confirm that the root canal lumen was empty from radiopaque materials (Group 1). Teeth were first irrigated with NanoCare Plus (Group 2) and then with NanoCare Gold (Group 3) and C-scans were repeated after each irrigation method. The OCT investigation started at the tooth apex, at a depth of 1 mm from its tip. Subsequently, 100 slices of 10 microns were obtained from each root canal. Images were captured and then analyzed with ImageJ software to calculate the level of grey inside the root canal lumen. The highest values of grey were obtained in the samples irrigated with NanoCare Gold after NanoCare Plus (Group 3). The present study proved that both nanoparticles inserted in root canal irrigants were evidenced through OCT imagistic analysis due to their optical opacity, which allowed their highlighting in an empty root canal lumen, after the endodontic treatment was performed and the root canal was cleaned and shaped using specific protocols.

12.
Materials (Basel) ; 14(15)2021 Jul 29.
Article in English | MEDLINE | ID: mdl-34361440

ABSTRACT

In order to overcome the limitations of current endodontic sealers, especially against resistant bacteria, recent developments in the field of nanotechnology have proved the necessity to reconsider the composition and physico-chemical properties of classical sealers. Nanoparticles with their unique features in terms of small size and high specific surface area, are the best choice for incorporation of antiseptic agents and effective delivery. The aim of our study is to prepare a novel platform for antibacterial drug delivery in dental adhesive systems used in endodontics. For this purpose, multi-walled carbon nanotubes (MWCNTs) encapsulating chlorhexidine (CHX) and colloidal silver nanoparticles (AgNPs) were prepared and incorporated into commercial sealer and investigated in terms of bonding performance to dentin and effectiveness against E. faecalis, S. aureus and Candida albicans, which are responsible for the majority of the failures in endodontic treatments. In this context, the challenges related to the long-term biological effects of CHX/AgNPs loaded MWCNTs are discussed.

13.
Medicina (Kaunas) ; 57(8)2021 Jul 29.
Article in English | MEDLINE | ID: mdl-34440981

ABSTRACT

Background and Objectives: Ceramic veneers represent the most appropriate treatment option for minimally invasive aesthetic rehabilitation. For long-term clinical success, the accurate marginal and internal adaptation of dental restorations are of paramount importance. The aim of this in vitro study is to assess the effect of a novel (patented) design of veneers compared to conventional ones on their marginal and internal gap to the prepared tooth surface. Materials and Methods: Twenty-four lithium disilicate ceramic veneers are obtained using Computer-Aided-Design (CAD) and then milled using Computer-Aided-Manufacturing (CAM). The samples are divided into two groups: 12 conventional (CO) veneers (i.e., with a linear marginal contour) and 12 crenelated (CR) veneers, the latter with the novel sinusoidal marginal design. All samples are bonded to frontal teeth, and the adhesive interfaces are analyzed using two methods, optical microscopy and micro-Computed Tomography (CT): the former for the accuracy of the marginal gap and the latter for the internal gap (as well as for the homogeneity of the luting cement) of ceramic veneers. Results: STATA and one-way ANOVA tests reveal significant differences between CO and CR veneers: (i) the marginal gap is smaller for CR (64 µm) than for CO veneers (236 µm); (ii) the internal adaptation is better for CR veneers: for a cement width of up to 120 µm, the covered surface for the CR group is 81.5%, while for the CO group it is 64.5%; (iii) the mean of the porosities within the cement is not significantly different (3.4·106 µm3 for CO and 3.9·106 µm3 for CR veneers), with a higher standard deviation for the CO group. Analytical modeling is achieved for internal gaps using the micro-CT results. The characteristic functions obtained allow us to compare the volume of luting cement for the two types of veneers. Conclusion: The novel veneers design produces an improvement in the marginal and internal adaptation of the restorations to the prepared tooth surface. Thus, it provides favorable premises for better clinical performances.


Subject(s)
Ceramics , Microscopy , Computer-Aided Design , Humans , Materials Testing , X-Ray Microtomography
14.
Sensors (Basel) ; 21(13)2021 Jul 02.
Article in English | MEDLINE | ID: mdl-34283107

ABSTRACT

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 µm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 µm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient's positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


Subject(s)
Cone-Beam Computed Tomography , Tomography, Optical Coherence , Dentistry , Humans , Imaging, Three-Dimensional , Phantoms, Imaging , X-Rays
15.
Materials (Basel) ; 14(9)2021 Apr 27.
Article in English | MEDLINE | ID: mdl-33925656

ABSTRACT

The design and development of ceramic structures based on 3D scaffolding as dental bone substitutes has become a topic of great interest in the regenerative dentistry research area. In this regard, the present study focuses on the development of two scaffold-type structures obtained from different commercial dental ceramics by employing the foam replication method. At the same time, the study underlines the physicochemical features and the biological profiles of the newly developed scaffolds, compared to two traditional Cerabone® materials used for bone augmentation, by employing both the in vitro Alamar blue proliferation test at 24, 48 and 96 h poststimulation and the in ovo chick chorioallantoic membrane (CAM) assay. The data reveal that the newly developed scaffolds express comparable results with the traditional Cerabone® augmentation masses. In terms of network porosity, the scaffolds show higher pore interconnectivity compared to Cerabone® granules, whereas regarding the biosafety profile, all ceramic samples manifest good biocompatibility on primary human gingival fibroblasts (HGFs); however only the Cerabone® samples induced proliferation of HGF cells following exposure to concentrations of 5 and 10 µg/mL. Additionally, none of the test samples induce irritative activity on the vascular developing plexus. Thus, based on the current results, the preliminary biosecurity profile of ceramic scaffolds supports the usefulness for further testing of high relevance for their possible clinical dental applications.

16.
Neurol Sci ; 42(11): 4511-4519, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33606127

ABSTRACT

BACKGROUND: Periodontal disease is an inflammatory, dysbiotic condition. Studies have shown that in the elderly, periodontal disease was associated with cognitive dysfunction and Alzheimer's disease. OBJECTIVE: To investigate whether young healthy subjects with periodontal disease have lower cognition compared to those without periodontal disease. The salivary cytokines (IL-1ß, TNF-α) levels in relation to cognition were also tested. METHODS: In a monocenter, cross-sectional study, forty subjects [mean age (SD) = 34 (5) and 48% female] from western Romania were classified into periodontal disease conditions using radiographic assessment: 10 subjects had aggressive periodontitis (AGG_P), 20 chronic mild-moderate periodontitis (CR_P), and 10 no periodontitis (NL_P). Neuropsychological assessment performed by standardized neurologists and psychologist included Rey Auditory Verbal Learning Test (RAVLT), Montreal Cognitive Assessment test (MOCA), Mini-Mental State Examination (MMSE), and Prague tests. Salivary cytokines levels were determined by ELISA. RESULTS: RAVLT and MOCA delayed recall scores were lower in AGG_P group compared to NL_P and CR_P. The learning curve was also different with subjects with AGG_P showing reduced learning performance. Contrary to our hypothesis, salivary IL-1ß associated with immediate but not delayed cognitive scores. CONCLUSIONS: These results showed for the first time that subjects with AGG_P had cognitive dysfunction and IL-1ß may play a role in this process.


Subject(s)
Alzheimer Disease , Cognitive Dysfunction , Periodontal Diseases , Aged , Cognitive Dysfunction/etiology , Cross-Sectional Studies , Female , Humans , Male , Mental Status and Dementia Tests , Neuropsychological Tests , Periodontal Diseases/complications
17.
Medicina (Kaunas) ; 57(2)2021 Feb 05.
Article in English | MEDLINE | ID: mdl-33562600

ABSTRACT

Background and Objectives: Antiresorptive or anti-angiogenic agents may induce medication-related osteonecrosis of the jaws (MRONJ), which represents a challenge for clinicians. The aim of this study is to design and apply a composed and stage-approach therapy combining antibiotherapy, surgical treatment, and photo-biomodulation (PBM) for the prevention or treatment of MRONJ lesions. Materials and Methods: The proposed treatment protocol was carried out in the Department of Oral & Maxillofacial Surgery of the "Victor Babes" University of Medicine and Farmacy of Timisoara, in 2018-2020. A total of 241 patients who were previously exposed to antiresorptive or anti-angiogenic therapy, as well as patients already diagnosed with MRONJ at different stages of the disease were treated. A preventive protocol was applied for patients in an "at risk" stage. Patients in more advanced stages received a complex treatment. Results: The healing proved to be complete, with spontaneous bone coverage in all the n = 84 cases placed in an "at risk" stage. For the n = 49 patients belonging to stage 0, pain reductions and decreases of mucosal inflammations were also obtained in all cases. For the n = 108 patients proposed for surgery (i.e., in stages 1, 2, or 3 of MRONJ), a total healing rate of 91.66% was obtained after the first surgery, while considering the downscaling to stage 1 as a treatment "success", only one "failure" was reported. This brings the overall "success" rate to 96.68% for a complete healing, and to 99.59% when downscaling to stage 1 is included in the healing rate. Conclusions: Therefore, the clinical outcome of the present study indicates that patients with MRONJ in almost all stages of the disease can benefit from such a proposed association of methods, with superior clinical results compared to classical therapies.


Subject(s)
Bisphosphonate-Associated Osteonecrosis of the Jaw , Bone Density Conservation Agents , Angiogenesis Inhibitors/adverse effects , Bisphosphonate-Associated Osteonecrosis of the Jaw/drug therapy , Bisphosphonate-Associated Osteonecrosis of the Jaw/surgery , Bone Density Conservation Agents/adverse effects , Humans , Jaw , Treatment Outcome
18.
Rom J Morphol Embryol ; 62(3): 793-800, 2021.
Article in English | MEDLINE | ID: mdl-35263408

ABSTRACT

OBJECTIVES: The goal of endodontic therapy is mechanically cleaning and shaping the root canal system, the removal of organic and inorganic debris followed by sealing with permanent filling materials. MATERIALS AND METHODS: Therefore, the aim of this in vitro study was to engage three imagistic methods: (i) en face (ef) time domain (TD) optical coherence tomography (OCT), (ii) micro-computed tomography (µCT), and (iii) scanning electron microscopy (SEM), in terms of their efficiency in assessing the quality of endodontic fillings. So far, is settled that efOCT images can identify defects∕voids in several of the investigated root canal fillings and identify gaps of 50 µm. RESULTS: The results delivered by µCT technology also showed several imperfections of the endodontic filling but also at the interfaces formed by the sealer and the root canal walls. SEM investigations highlights the complex form of the interface formed the endodontic filling material and the walls of the root canal, as well as shortcomings of the materials from several samples. Gaps of 50 µm are identified with efOCT. CONCLUSIONS: The net advantage of OCT technology, in respect to the other two technologies consists in its non-invasiveness. The OCT axial resolution is also sufficient to see the material gaps. Another advantage of efOCT investigations is that they allow real-time imaging of complex arrangement at the interfaces of the filling material with dentinal root.


Subject(s)
Root Canal Filling Materials , Dental Pulp Cavity , Humans , Microscopy, Electron, Scanning , Root Canal Therapy , Tomography, Optical Coherence , X-Ray Microtomography/methods
19.
Rom J Morphol Embryol ; 62(2): 537-543, 2021.
Article in English | MEDLINE | ID: mdl-35024742

ABSTRACT

OBJECTIVES: The purpose of this study was to demonstrate the efficacy of Silver Diamine Fluoride (SDF) antibacterial solution in penetrating the demineralized areas of enamel. MATERIALS AND METHODS: It was considered a group of four extracted teeth (with no color fading, fissures, decay, or demineralization). Each tooth was sectioned in two equal parts, in mesio-distal direction, using a dental handpiece and a special rounded, flat bur. Each specimen was demineralized, for one minute, with 45% orthophosphoric acid, on occlusal and proximal zones. The specimens were then washed and dried with water-air dental syringe. All the probes were inspected with an optical microscope and enamel thickness was digitally measured. Advantage Arrest (Elevate Oral Care, USA), which contains SDF, was applied on the previous demineralized zones. The penetration of the substance was visually inspected with the optical microscope and electronically measured. RESULTS: It was observed an improvement in remineralizing the white spots on enamel surfaces, the optical microscope being able to detect both demineralization and the penetration of SDF through enamel. CONCLUSIONS: Based on our in vitro study, SDF (Advantage Arrest) was capable to induce/increase enamel remineralization, through SDF penetration.


Subject(s)
Dental Caries , Fluorides, Topical , Humans , Quaternary Ammonium Compounds/pharmacology , Silver Compounds
20.
J Prosthodont Res ; 65(3): 371-378, 2021 Aug 21.
Article in English | MEDLINE | ID: mdl-32981911

ABSTRACT

Purpose This in vitro study aimed at ascertaining the retention forces for telescopic crowns fabricated with Selective Laser Manufacturing (SLM) and Selective Laser Sintering (SLS) additive technologies, and Computer Aided Design - Computer Aided Manufacturing (CAD-CAM) subtractive technology, by using suitable materials for each.Materials and Methods Full-factorial design was employed for experimental testing, considering the following three factors: (a) inner crown material ‒ technology (zirconia ‒ CAD-CAM; metal-alloy ‒ SLS; metal-alloy ‒ SLM); (b) tooth type (canine or molar); (c) wet vs. dry conditions (i.e. either with or without artificial saliva). The roughness of the inner crowns was analyzed through atomic force microscopy. Three-way analysis of variance (ANOVA) was applied for statistical analysis, followed by Tukey's post-hoc comparisons between the crown types.Results The retention force mean values were between 3.8 N (dry, SLM) and 14.8 N (artificial saliva, SLS), with statistically significant (p<0.001) differences between the three types of inner crowns and interaction with the tooth type. No significant interaction was found between crown or tooth types and the wet vs. dry testing conditions. The zirconia crowns' retention force was significantly (p<0.001) higher compared to similar SLM crowns, with 95% CI (3.62; 5.55) N for the differences. Zirconia was significantly (p<0.001) less retentive compared to similar SLS crowns, with 95% CI (-5.99; -4.06) N for the differences. The roughness decrease and subsequent loss of retention force was the largest in zirconia.Conclusions The SLS inner crowns showed the best retention, followed by zirconia and SLM inner crows.


Subject(s)
Computer-Aided Design , Dental Prosthesis Design , Crowns , Lasers , Materials Testing , Zirconium
SELECTION OF CITATIONS
SEARCH DETAIL
...