Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Thorac Surg ; 107(5): e321-e323, 2019 May.
Article in English | MEDLINE | ID: mdl-30315797

ABSTRACT

The clinical experience with Loeys-Dietz syndrome (LDS) reveals fateful natural history with intracerebral incidents and aortic dissections. A newborn child was referred to our hospital with significantly dilated aortic root and clinical signs of LDS phenotype later genetically confirmed as LDS type I. A therapy with antihypertensive medicines was initiated to postpone the surgery. Despite that, aortic root dilatation progressed to 33 mm (z-score +9.3). To avoid aortic rupture, a valve sparing aortic root replacement was performed at patient age of 8 months. The purpose of this report is to share our dilemmas and experience in the treatment of this child.


Subject(s)
Aorta/surgery , Blood Vessel Prosthesis Implantation , Loeys-Dietz Syndrome/surgery , Humans , Infant , Infant, Newborn , Loeys-Dietz Syndrome/diagnosis , Male
2.
J Cardiothorac Vasc Anesth ; 16(5): 592-7, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12407612

ABSTRACT

OBJECTIVE: To assess cardiac output, intrathoracic blood volume, global end-diastolic volume, and extravascular lung water in critically ill neonates and small infants using transpulmonary indicator dilution. DESIGN: Prospective, observational, clinical study. SETTING: Pediatric intensive care unit in a university hospital. PARTICIPANTS: Critically ill neonates and small infants suffering from severe heart failure, respiratory failure, or sepsis (n = 10). INTERVENTIONS: A total of 194 transpulmonary indicator dilution measurements were done. Global end-diastolic volume, intrathoracic blood volume, and stroke volume were measured and compared with standard hemodynamic parameters during the clinical course and before and after volume loading (16 +/- 3.7 mL/kg of 10% albumin solution) in 8 of 10 patients. MEASUREMENTS AND MAIN RESULTS: A positive correlation was found for stroke volume index versus global end-diastolic volume (r = 0.76, p < 0.001) and intrathoracic blood volume (r = 0.56, p < 0.001). In contrast, no correlation was observed for stroke volume index versus central venous pressure. Volume loading resulted in significant increases in stroke volume index (p < 0.01), global end-diastolic volume (p < 0.01), and intrathoracic blood volume (p < 0.01); whereas central venous pressure, heart rate, mean arterial pressure, and extravascular lung water remained unchanged. CONCLUSION: Transpulmonary indicator dilution enables measurement of cardiac output and intravascular volume status in critically ill neonates and infants at the bedside. The effects of volume loading on cardiac preload and effective change in stroke volume can be monitored by this technique, whereas central venous pressure was not indicative of changes in intravascular volume status.


Subject(s)
Cardiac Output , Extravascular Lung Water , Indicator Dilution Techniques , Blood Volume , Critical Illness , Diastole , Humans , Infant , Prospective Studies , Stroke Volume
SELECTION OF CITATIONS
SEARCH DETAIL
...