Dent Mater ; 29(12): e318-24, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24183054

ABSTRACT

OBJECTIVE: Comparison of physical and mechanical properties of one conventional and a new NiTi wire, which had received an additional thermomechanical treatment. METHODS: Specimens of both conventional (NiTi) and the new type of wire, called M-Wire (MW), were subjected to tensile and three-point bending tests, Vickers microhardness measurements, and to rotating-bending fatigue tests at a strain-controlled level of 6%. Fracture surfaces were observed by scanning electron microscopy and the non-deformed microstructures by transmission electron microscopy. RESULTS: The thermomechanical treatment applied to produce the M-Wire apparently increased the tensile strength and Vickers microhardness of the material, but its apparent Young modulus was smaller than that of conventionally treated NiTi. The three-point bending tests showed a higher flexibility for MW which also exhibited a significantly higher number of cycles to failure. SIGNIFICANCE: M-Wire presented mechanical properties that can render endodontic instruments more flexible and fatigue resistant than those made with conventionally processed NiTi wires.


Subject(s)
Endodontics/instrumentation , Materials Testing , Nickel , Titanium , Microscopy, Electron, Scanning , Microscopy, Electron, Transmission , Tensile Strength