Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters











Publication year range
1.
IEEE J Sel Top Appl Earth Obs Remote Sens ; 11(6): 2059-2067, 2018 Jun.
Article in English | MEDLINE | ID: mdl-33376571

ABSTRACT

The societal benefits of understanding climate change through the identification of global carbon dioxide sources and sinks led to the recommendation for NASA's Active Sensing of Carbon Dioxide Emissions over Nights, Days, and Seasons space-based mission for global carbon dioxide measurements. For more than 15 years, the NASA Langley Research Center has developed several carbon dioxide active remote sensors using the differential absorption lidar technique operating at 2-µm wavelength. Recently, an airborne double-pulsed integrated path differential absorption lidar was developed, tested, and validated for atmospheric carbon dioxide measurement. Results indicated 1.02% column carbon dioxide measurement uncertainty and 0.28% bias over the ocean. Currently, this technology is progressing toward triple-pulse operation targeting both atmospheric carbon dioxide and water vapor-the dominant interfering molecule on carbon dioxide remote sensing. Measurements from the double-pulse lidar and the advancement of the triple-pulse lidar development are presented. In addition, measurement simulations with a space-based IPDA lidar, incorporating new technologies, are also presented to assess feasibility of carbon dioxide measurements from space.

2.
Appl Opt ; 56(23): 6531-6547, 2017 Aug 10.
Article in English | MEDLINE | ID: mdl-29047943

ABSTRACT

Sustained high-quality column carbon dioxide (CO2) atmospheric measurements from space are required to improve estimates of regional and continental-scale sources and sinks of CO2. Modeling of a space-based 2 µm, high pulse energy, triple-pulse, direct detection integrated path differential absorption (IPDA) lidar was conducted to demonstrate CO2 measurement capability and to evaluate random and systematic errors. Parameters based on recent technology developments in the 2 µm laser and state-of-the-art HgCdTe (MCT) electron-initiated avalanche photodiode (e-APD) detection system were incorporated in this model. Strong absorption features of CO2 in the 2 µm region, which allows optimum lower tropospheric and near surface measurements, were used to project simultaneous measurements using two independent altitude-dependent weighting functions with the triple-pulse IPDA. Analysis of measurements over a variety of atmospheric and aerosol models using a variety of Earth's surface target and aerosol loading conditions were conducted. Water vapor (H2O) influences on CO2 measurements were assessed, including molecular interference, dry-air estimate, and line broadening. Projected performance shows a <0.35 ppm precision and a <0.3 ppm bias in low-tropospheric weighted measurements related to column CO2 optical depth for the space-based IPDA using 10 s signal averaging over the Railroad Valley (RRV) reference surface under clear and thin cloud conditions.

3.
Appl Opt ; 55(15): 4232-46, 2016 May 20.
Article in English | MEDLINE | ID: mdl-27411155

ABSTRACT

Field experiments were conducted to test and evaluate the initial atmospheric carbon dioxide (CO2) measurement capability of airborne, high-energy, double-pulsed, 2-µm integrated path differential absorption (IPDA) lidar. This IPDA was designed, integrated, and operated at the NASA Langley Research Center on-board the NASA B-200 aircraft. The IPDA was tuned to the CO2 strong absorption line at 2050.9670 nm, which is the optimum for lower tropospheric weighted column measurements. Flights were conducted over land and ocean under different conditions. The first validation experiments of the IPDA for atmospheric CO2 remote sensing, focusing on low surface reflectivity oceanic surface returns during full day background conditions, are presented. In these experiments, the IPDA measurements were validated by comparison to airborne flask air-sampling measurements conducted by the NOAA Earth System Research Laboratory. IPDA performance modeling was conducted to evaluate measurement sensitivity and bias errors. The IPDA signals and their variation with altitude compare well with predicted model results. In addition, off-off-line testing was conducted, with fixed instrument settings, to evaluate the IPDA systematic and random errors. Analysis shows an altitude-independent differential optical depth offset of 0.0769. Optical depth measurement uncertainty of 0.0918 compares well with the predicted value of 0.0761. IPDA CO2 column measurement compares well with model-driven, near-simultaneous air-sampling measurements from the NOAA aircraft at different altitudes. With a 10-s shot average, CO2 differential optical depth measurement of 1.0054±0.0103 was retrieved from a 6-km altitude and a 4-GHz on-line operation. As compared to CO2 weighted-average column dry-air volume mixing ratio of 404.08 ppm, derived from air sampling, IPDA measurement resulted in a value of 405.22±4.15 ppm with 1.02% uncertainty and 0.28% additional bias. Sensitivity analysis of environmental systematic errors correlates the additional bias to water vapor. IPDA ranging resulted in a measurement uncertainty of <3 m.

4.
Appl Opt ; 54(24): 7240-51, 2015 Aug 20.
Article in English | MEDLINE | ID: mdl-26368759

ABSTRACT

Double-pulsed 2-µm integrated path differential absorption (IPDA) lidar is well suited for atmospheric CO2 remote sensing. The IPDA lidar technique relies on wavelength differentiation between strong and weak absorbing features of the gas normalized to the transmitted energy. In the double-pulse case, each shot of the transmitter produces two successive laser pulses separated by a short interval. Calibration of the transmitted pulse energies is required for accurate CO2 measurement. Design and calibration of a 2-µm double-pulse laser energy monitor is presented. The design is based on an InGaAs pin quantum detector. A high-speed photoelectromagnetic quantum detector was used for laser-pulse profile verification. Both quantum detectors were calibrated using a reference pyroelectric thermal detector. Calibration included comparing the three detection technologies in the single-pulsed mode, then comparing the quantum detectors in the double-pulsed mode. In addition, a self-calibration feature of the 2-µm IPDA lidar is presented. This feature allows one to monitor the transmitted laser energy, through residual scattering, with a single detection channel. This reduces the CO2 measurement uncertainty. IPDA lidar ground validation for CO2 measurement is presented for both calibrated energy monitor and self-calibration options. The calibrated energy monitor resulted in a lower CO2 measurement bias, while self-calibration resulted in a better CO2 temporal profiling when compared to the in situ sensor.

5.
Appl Opt ; 54(6): 1387-98, 2015 Feb 20.
Article in English | MEDLINE | ID: mdl-25968204

ABSTRACT

Water vapor and carbon dioxide are the most dominant greenhouse gases directly contributing to the Earth's radiation budget and global warming. A performance evaluation of an airborne triple-pulsed integrated path differential absorption (IPDA) lidar system for simultaneous and independent monitoring of atmospheric water vapor and carbon dioxide column amounts is presented. This system leverages a state-of-the-art Ho:Tm:YLF triple-pulse laser transmitter operating at 2.05 µm wavelength. The transmitter provides wavelength tuning and locking capabilities for each pulse. The IPDA lidar system leverages a low risk and technologically mature receiver system based on InGaAs pin detectors. Measurement methodology and wavelength setting are discussed. The IPDA lidar return signals and error budget are analyzed for airborne operation on-board the NASA B-200. Results indicate that the IPDA lidar system is capable of measuring water vapor and carbon dioxide differential optical depth with 0.5% and 0.2% accuracy, respectively, from an altitude of 8 km to the surface and with 10 s averaging. Provided availability of meteorological data, in terms of temperature, pressure, and relative humidity vertical profiles, the differential optical depth conversion into weighted-average column dry-air volume-mixing ratio is also presented.

6.
Opt Lett ; 37(13): 2562-4, 2012 Jul 01.
Article in English | MEDLINE | ID: mdl-22743455

ABSTRACT

A fully conductively cooled and diode-pumped linear Ho:Tm:LuLiF laser oscillator can generate more than 1 J normal mode pulses at a 10 Hz pulse repetition rate where heat pipes are used for cooling pump diodes and laser crystal. As an amplifier, it can amplify the 80 mJ/180 ns pulses into 400 mJ pulses before the appearance of amplified spontaneous emission (ASE). The ASE threshold is about 5.6 J with a 40 mm long and side-polished laser crystal. For a 5 mJ input pulse and 5.6 J pump pulse, the double-pass gain exceeds 22.5. If the lateral surface of the laser crystal is fine ground, the ASE threshold can rise to higher than 8 J, but the efficiency will be lower due to large pump diffusion.


Subject(s)
Lasers, Solid-State , Temperature , Models, Theoretical
7.
Echocardiography ; 29(8): E201-3, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22640014

ABSTRACT

The presence of hepatic portal venous gas (HPVG) may be secondary to bowel necrosis, mechanical distension, or intraabdominal sepsis. We describe an unusual and hitherto unreported presence of HPVG manifesting as gas embolization and the unique "aquarium sign" in a patient of Kawasaki's disease. Continuous passage of bubble-like echoes flowing from the hepatic portal venous system into the inferior vena cava and right-sided chambers of heart was noted on echocardiography. The patient was treated with intravenous immune-globulins and made an uneventful recovery.


Subject(s)
Embolism, Air/diagnostic imaging , Embolism, Air/etiology , Hepatic Veins/diagnostic imaging , Intussusception/diagnostic imaging , Intussusception/etiology , Mucocutaneous Lymph Node Syndrome/complications , Mucocutaneous Lymph Node Syndrome/diagnostic imaging , Child, Preschool , Echocardiography/methods , Humans , Male
8.
Appl Opt ; 47(29): 5281-95, 2008 Oct 10.
Article in English | MEDLINE | ID: mdl-18846166

ABSTRACT

Backscatter lidar detection systems have been designed and integrated at NASA Langley Research Center using IR heterojunction phototransistors. The design focused on maximizing the system signal-to-noise ratio rather than noise minimization. The detection systems have been validated using the Raman-shifted eye-safe aerosol lidar (REAL) at the National Center for Atmospheric Research. Incorporating such devices introduces some systematic effects in the form of blurring to the backscattered signals. Characterization of the detection system transfer function aided in recovering such effects by deconvolution. The transfer function was obtained by measuring and fitting the system impulse response using single-pole approximation. An iterative deconvolution algorithm was implemented in order to recover the system resolution, while maintaining high signal-to-noise ratio. Results indicated a full recovery of the lidar signal, with resolution matching avalanche photodiodes. Application of such a technique to atmospheric boundary and cloud layers data restores the range resolution, up to 60 m, and overcomes the blurring effects.

9.
Appl Opt ; 47(7): 944-56, 2008 Mar 01.
Article in English | MEDLINE | ID: mdl-18311266

ABSTRACT

A 2 microm wavelength, 90 mJ, 5 Hz pulsed Ho laser is described with wavelength control to precisely tune and lock the wavelength at a desired offset up to 2.9 GHz from the center of a CO(2) absorption line. Once detuned from the line center the laser wavelength is actively locked to keep the wavelength within 1.9 MHz standard deviation about the setpoint. This wavelength control allows optimization of the optical depth for a differential absorption lidar (DIAL) measuring atmospheric CO(2) concentrations. The laser transmitter has been coupled with a coherent heterodyne receiver for measurements of CO(2) concentration using aerosol backscatter; wind and aerosols are also measured with the same lidar and provide useful additional information on atmospheric structure. Range-resolved CO(2) measurements were made with <2.4% standard deviation using 500 m range bins and 6.7 min? (1000 pulse pairs) integration time. Measurement of a horizontal column showed a precision of the CO(2) concentration to <0.7% standard deviation using a 30 min? (4500 pulse pairs) integration time, and comparison with a collocated in situ sensor showed the DIAL to measure the same trend of a diurnal variation and to detect shorter time scale CO(2) perturbations. For vertical column measurements the lidar was setup at the WLEF tall tower site in Wisconsin to provide meteorological profiles and to compare the DIAL measurements with the in situ sensors distributed on the tower up to 396 m height. Assuming the DIAL column measurement extending from 153 m altitude to 1353 m altitude should agree with the tower in situ sensor at 396 m altitude, there was a 7.9 ppm rms difference between the DIAL and the in situ sensor using a 30 min? rolling average on the DIAL measurement.

10.
Opt Lett ; 31(4): 462-4, 2006 Feb 15.
Article in English | MEDLINE | ID: mdl-16496887

ABSTRACT

Q-switched output of 1.1 J/pulse at a 2.053 microm wavelength has been achieved in a diode-pumped Ho: Tm: LuLF laser with a side-pumped rod configuration in a master-oscillator-power-amplifier (MOPA) architecture. This is the first time to our knowledge that a 2 microm laser has broken the joule per pulse barrier for Q-switched operation. The total system efficiency reaches 5% and 6.2% for single- and double-pulse operation, respectively. The system produces an excellent 1.4 times transform-limited beam quality.

11.
Appl Opt ; 43(26): 5092-9, 2004 Sep 10.
Article in English | MEDLINE | ID: mdl-15468711

ABSTRACT

A differential absorption lidar has been built to measure CO2 concentration in the atmosphere. The transmitter is a pulsed single-frequency Ho:Tm:YLF laser at a 2.05-microm wavelength. A coherent heterodyne receiver was used to achieve sensitive detection, with the additional capability for wind profiling by a Doppler technique. Signal processing includes an algorithm for power measurement of a heterodyne signal. Results show a precision of the CO2 concentration measurement of 1%-2% 1sigma standard deviation over column lengths ranging from 1.2 to 2.8 km by an average of 1000 pulse pairs. A preliminary assessment of instrument sensitivity was made with an 8-h-long measurement set, along with correlative measurements with an in situ sensor, to determine that a CO2 trend could be detected.

12.
Appl Opt ; 41(9): 1718-21, 2002 Mar 20.
Article in English | MEDLINE | ID: mdl-11921801

ABSTRACT

We demonstrate wavelength control of a single-frequency diode-pumped Ho:Tm:YLF laser by referencing its wavelength to an absorption line of carbon dioxide. We accomplish this wavelength control by injection seeding with a cw Ho:Tm:YLF laser that can be tuned over or stabilized to carbon dioxide or water vapor lines. We show that the pulsed laser can be scanned precisely over an absorption line of carbon dioxide by scanning the injection seed laser wavelength. We locked the pulsed laser to within 18.5 MHz of the absorption line center by stabilizing the injection seed on the line center. The single-frequency pulsed output, intended for use as a transmitter for differential absorption lidar detection of atmospheric carbon dioxide and water vapor and for coherent detection of wind, is 100 mJ per pulse at a 5-Hz repetition rate.

SELECTION OF CITATIONS
SEARCH DETAIL