Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Heart J Cardiovasc Imaging ; 24(6): 796-806, 2023 05 31.
Article in English | MEDLINE | ID: mdl-36099163

ABSTRACT

AIMS: Bioprosthetic valve dysfunction (BVD) is a major concern regarding transcatheter aortic valve implantation (TAVI) durability. We aimed to assess incidence, correlates, causes, and outcome of early to mid-term BVD after TAVI in relation to patient's life expectancy. METHODS AND RESULTS: Consecutive TAVI recipients (2007-20) with a follow-up ≥1 year were prospectively included. BVD and bioprosthetic valve failure (BVF) were assessed according to Valve-Academic-Research-Consortium-3. BVD/BVF and all-cause death served as endpoints. Average life expectancy was calculated from National Open Health Data and patients were stratified according to tertiles (1st: <6.85 years, 2nd: 6.85-9.7 years, 3rd: >9.7 years). Of 1047 patients (81.6 ± 6.8 years old, EuroSCORE II 4.5 ± 2.5), ≥2 follow ups were available from 622 (serial echo cohort). After a median echo follow up of 12.2 months, incidence rates of BVD/BVF were 8.4% (95% confidence interval 6.7-10.3), and 3.5% (2.5-4.9) per valve-year, respectively, without differences between life expectancy tertiles. The incidence of BVD was two-fold higher within the first year of implant (9.9% per valve-year) vs. beyond (4.8% per valve-year). Valve-in-valve procedure and residual stenosis, but not age/life expectancy predisposed for BVD. BVD/BVF were independently associated with outcome for patients in the first [adjusted hazard ratio (AHR) 1.72 (1.06-2.88)/2.97 (1.72-6.22)] and second [AHR 1.96 (1.02-3.73)/2.31 (1.00-5.30)], but not the third tertile of life expectancy (P = n.s.). CONCLUSIONS: In this large prospective observational cohort, early to mid-term BVD after TAVI occurred at the same rate across the spectrum of life expectancy and was associated with increased mortality in patients with short but not in those with the longest life expectancy.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Incidence , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome
2.
ESC Heart Fail ; 8(2): 1408-1416, 2021 04.
Article in English | MEDLINE | ID: mdl-33580746

ABSTRACT

AIMS: Fluid overload (FO) puts aortic stenosis (AS) patients at risk for heart failure (HF) and death. However, conventional FO assessment, including rapid weight gain, peripheral oedema, or chest radiography, is inaccurate. Bioelectrical impedance spectroscopy (BIS) allows objective and reproducible FO quantification, particularly if clinically unapparent. It is used in dialysis patients to establish dry weight goals. BIS has not been tested for prognostication in AS. This study aimed to evaluate whether BIS adds prognostic information in stable patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: Consecutive patients scheduled for TAVR underwent BIS in addition to echocardiographic, clinical, and laboratory assessment. On BIS, mild FO was defined as >1.0 L and severe as >3.0 L. Combined HF hospitalization and/or all-cause death was defined as primary endpoint. Three hundred forty-four patients (81.5 ± 7.2 years old, 47.4% female) were prospectively included. FO by BIS was associated with clinical congestion signs, higher serum markers of cardiac injury, poorer left ventricular function, higher pulmonary pressures, and more severe tricuspid regurgitation (all P < 0.05). Yet, clinical examination was unremarkable in >30% in mild FO, only detected by BIS. During 12.1 ± 5.5 months, 67 (19.5%) events were recorded (40 deaths, 15 HF hospitalizations, and 12 both). Quantitatively, every 1 L increase in FO was associated with a 24% (HR 1.24, 95% CI 1.13-1.35, P < 0.001) increase in event hazard. This association persisted after adjustment for STS/EuroSCORE-II, NT-proBNP, left ventricular ejection fraction, and renal function. CONCLUSIONS: In patients undergoing TAVR, FO by BIS is strongly associated with adverse outcomes. BIS measurement conveys prognostic information not represented in any currently used AS/TAVR risk assessments.


Subject(s)
Heart Failure , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Nephrologists , Stroke Volume , Treatment Outcome , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...