Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Language
Publication year range
1.
J Clin Med ; 13(10)2024 May 19.
Article in English | MEDLINE | ID: mdl-38792523

ABSTRACT

Background/Objectives: Patient care in Cardiac Intensive Care Units (CICU) has evolved but data on patient characteristics and outcomes are sparse. This retrospective observational study aimed to define clinical characteristics and risk factors of CICU patients, their in-hospital and 30-day mortality, and compare it with established risk scores. Methods: Consecutive patients (n = 294, mean age 70 years, 74% males) hospitalized within 15 months were studied; APACHE II, EHMRG, GWTG-HF, and GRACE II were calculated on admission. Results: Most patients were admitted for ACS (48.3%) and acute decompensated heart failure (ADHF) (31.3%). Median duration of hospitalization was 2 days (IQR = 1, 4). In-hospital infection occurred in 20%, 18% needed mechanical ventilation, 10% renal replacement therapy and 4% percutaneous ventricular assist devices (33%, 29%, 20% and 4%, respectively, for ADHF). In-hospital and 30-day mortality was 18% and 11% for all patients (29% and 23%, respectively, for ADHF). Established scores (especially APACHE II) had a good diagnostic accuracy (area under the curve-AUC). In univariate and multivariate analyses in-hospital intubation and infection, history of coronary artery disease, hypotension, uremia and hypoxemia on admission were the most important risk factors. Based on these, a proposed new score showed a diagnostic accuracy of 0.954 (AUC) for in-hospital mortality, outperforming previous scores. Conclusions: Patients are admitted mainly with ACS or ADHF, the latter with worse prognosis. Several patients need advanced support; intubation and infections adversely affect prognosis. Established scores predict mortality satisfactorily, but larger studies are needed to develop CICU-directed scores to identify risk factors, improve prediction, guide treatment and staff training.

2.
J Clin Med ; 13(8)2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38673515

ABSTRACT

The fractional flow reserve (FFR) is well recognized as a gold standard measure for the estimation of functional coronary stenosis. Technological progressions in image processing have empowered the reconstruction of three-dimensional models of the coronary arteries via both non-invasive and invasive imaging modalities. The application of computational fluid dynamics (CFD) techniques to coronary 3D anatomical models allows the virtual evaluation of the hemodynamic significance of a coronary lesion with high diagnostic accuracy. METHODS: Search of the bibliographic database for articles published from 2011 to 2023 using the following search terms: invasive FFR and non-invasive FFR. Pooled analysis of the sensitivity and specificity, with the corresponding confidence intervals from 32% to 94%. In addition, the summary processing times were determined. RESULTS: In total, 24 studies published between 2011 and 2023 were included, with a total of 13,591 patients and 3345 vessels. The diagnostic accuracy of the invasive and non-invasive techniques at the per-patient level was 89% (95% CI, 85-92%) and 76% (95% CI, 61-80%), respectively, while on the per-vessel basis, it was 92% (95% CI, 82-88%) and 81% (95% CI, 75-87%), respectively. CONCLUSION: These opportunities providing hemodynamic information based on anatomy have given rise to a new era of functional angiography and coronary imaging. However, further validations are needed to overcome several scientific and computational challenges before these methods are applied in everyday clinical practice.

3.
Cardiovasc. revasc. med ; 29: 9-15, Aug. 2021. graf, ilus, tab
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1293172

ABSTRACT

BACKGROUND/PURPOSE: Local hemodynamic forces such as endothelial shear stress (ESS) may have an influence on appropriate neointimal healing, vessel remodeling, and struts absorption process following second-generation drug-eluting resorbable magnesium scaffold (RMS, Magmaris, Biotronik AG, Buelach, Switzerland) placement. The aim of this study was to investigate the impact of ESS assessed by optical coherence tomography (OCT)- based computational fluid dynamic (CFD) simulations on absorption process and coronary lumen dimension after Magmaris implantation. METHODS AND RESULTS: A total of 22 patients who were enrolled in the BIOSOLVE-II trial and underwent serial OCT assessment immediately after Magmaris implantation and at 6- and 12-month follow-up were included. We evaluated qualitative OCT findings frame by frame, and CFD simulations were performed to calculate the ESS at 3-dimensional (3D) reconstructed arteries. For quantitative calculation, the average ESS within each 1-mm section was classified into three groups: low (2.5 Pa). A significant difference of percentage remnants of scaffold was observed among the 3 groups at 12-month follow-up (P = 0.001) but not at 6-month follow-up. Low-ESS segment at baseline resulted in a greater lumen change of −1.857 ± 1.902 mm2 at 1 year compared to −1.277 ± 1.562 mm2 in the intermediate-ESS segment (P = 0.017) and − 0.709 ± 1.213 mm2 in the high-ESS segment (P = 0.001). CONCLUSION: After Magmaris implantation, the presence of higher ESS might be associated with slower strut absorption process but less luminal loss. SUMMARY FOR TABLE OF CONTENTS: The authors analyzed 22 patients from the BIOSOLVE-II trial who underwent optical coherence tomography assessment immediately after receiving a Magmaris second-generation drug-eluting resorbable magnesium scaffold. The analysis found that after Magmaris implantation, the presence of higher endothelial shear stress (ESS) might be associated with slower strut absorption process but less luminal loss. This study is the first demonstrating the impact of ESS assessed by OCT on absorption process and coronary lumen dimension after Magmaris implantation.


Subject(s)
Absorbable Implants , Tomography, Optical Coherence , Magnesium , Shear Strength , Drug-Eluting Stents
4.
Cardiovasc Revasc Med ; 29: 9-15, 2021 08.
Article in English | MEDLINE | ID: mdl-33863661

ABSTRACT

BACKGROUND/PURPOSE: Local hemodynamic forces such as endothelial shear stress (ESS) may have an influence on appropriate neointimal healing, vessel remodeling, and struts' absorption process following second-generation drug-eluting resorbable magnesium scaffold (RMS, Magmaris, Biotronik AG, Buelach, Switzerland) placement. The aim of this study was to investigate the impact of ESS assessed by optical coherence tomography (OCT)-based computational fluid dynamic (CFD) simulations on absorption process and coronary lumen dimension after Magmaris implantation. METHODS AND RESULTS: A total of 22 patients who were enrolled in the BIOSOLVE-II trial and underwent serial OCT assessment immediately after Magmaris implantation and at 6- and 12-month follow-up were included. We evaluated qualitative OCT findings frame by frame, and CFD simulations were performed to calculate the ESS at 3-dimensional (3D) reconstructed arteries. For quantitative calculation, the average ESS within each 1-mm section was classified into three groups: low (<1.0 Pa), intermediate (1.0-2.5 Pa), or high (>2.5 Pa). A significant difference of percentage remnants of scaffold was observed among the 3 groups at 12-month follow-up (P = 0.001) but not at 6-month follow-up. Low-ESS segment at baseline resulted in a greater lumen change of -1.857 ± 1.902 mm2 at 1 year compared to -1.277 ± 1.562 mm2 in the intermediate-ESS segment (P = 0.017) and - 0.709 ± 1.213 mm2 in the high-ESS segment (P = 0.001). CONCLUSION: After Magmaris implantation, the presence of higher ESS might be associated with slower strut absorption process but less luminal loss.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Pharmaceutical Preparations , Absorbable Implants , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Humans , Magnesium , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Tomography, Optical Coherence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...