1.
IEEE Trans Biomed Eng ; 54(1): 138-49, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17260865

ABSTRACT

Cochlear implants currently fail to convey phase information, which is important for perceiving music, tonal languages, and for hearing in noisy environments. We propose a bio-inspired asynchronous interleaved sampling (AIS) algorithm that encodes both envelope and phase information, in a manner that may be suitable for delivery to cochlear implant users. Like standard continuous interleaved sampling (CIS) strategies, AIS naturally meets the interleaved-firing requirement, which is to stimulate only one electrode at a time, minimizing electrode interactions. The majority of interspike intervals are distributed over 1-4 ms, thus staying within the absolute refractory limit of neurons, and form a more natural, pseudostochastic pattern of firing due to complex channel interactions. Stronger channels are selected to fire more often but the strategy ensures that weaker channels are selected to fire in proportion to their signal strength as well. The resulting stimulation rates are considerably lower than those of most modern implants, saving power yet delivering higher potential performance. Correlations with original sounds were found to be significantly higher in AIS reconstructions than in signal reconstructions using only envelope information. Two perceptual tests on normal-hearing listeners verified that the reconstructed signals enabled better melody and speech recognition in noise than those processed using tone-excited envelope-vocoder simulations of cochlear implant processing. Thus, our strategy could potentially save power and improve hearing performance in cochlear implant users.


Subject(s)
Algorithms , Cochlear Implants , Information Storage and Retrieval/methods , Sound Spectrography/instrumentation , Sound Spectrography/methods , Speech Recognition Software , Therapy, Computer-Assisted/methods , Equipment Design , Equipment Failure Analysis , Therapy, Computer-Assisted/instrumentation
2.
IEEE Trans Biomed Eng ; 52(4): 711-27, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15825873

ABSTRACT

We report a programmable analog bionic ear (cochlear implant) processor in a 1.5-microm BiCMOS technology with a power consumption of 211 microW and 77-dB dynamic range of operation. The 9.58 mm x 9.23 mm processor chip runs on a 2.8 V supply and has a power consumption that is lower than state-of-the-art analog-to-digital (A/D)-then-DSP designs by a factor of 25. It is suitable for use in fully implanted cochlear-implant systems of the future which require decades of operation on a 100-mAh rechargeable battery with a finite number of charge-discharge cycles. It may also be used as an ultra-low-power spectrum-analysis front end in portable speech-recognition systems. The power consumption of the processor includes the 100 microW power consumption of a JFET-buffered electret microphone and an associated on-chip microphone front end. An automatic gain control circuit compresses the 77-dB input dynamic range into a narrower internal dynamic range (IDR) of 57 dB at which each of the 16 spectral channels of the processor operate. The output bits of the processor are scanned and reported off chip in a format suitable for continuous-interleaved-sampling stimulation of electrodes. Power-supply-immune biasing circuits ensure robust operation of the processor in the high-RF-noise environment typical of cochlear implant systems.


Subject(s)
Algorithms , Bionics/instrumentation , Cochlear Implants , Microcomputers , Signal Processing, Computer-Assisted/instrumentation , Sound Spectrography/instrumentation , Electric Power Supplies , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity