Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Int Orthop ; 47(5): 1267-1275, 2023 05.
Article in English | MEDLINE | ID: mdl-36763126

ABSTRACT

PURPOSE: Glenoid component loosening is a potential complication of reverse total shoulder arthroplasty (rTSA), occurring in part due to lack of adequate screw purchase in quality scapular bone stock. This study was to determine the efficacy of a surgeon-designed, 3D-printed patient-specific instrumentation (PSI) compared to conventional instrumentation (CI) in achieving longer superior and inferior screw lengths for glenoid component fixation. METHODS: A multi-centre retrospective analysis of patients who underwent rTSA between 2015 and 2020. Lengths of the superior and inferior locking screws inserted for fixation of the glenoid baseplate component were recorded and compared according to whether patients received PSI or CI. Secondary outcomes included operative duration and incidence of complications requiring revision surgery. RESULTS: Seventy-three patients (31 PSI vs. 42 CI) were analysed. Average glenoid diameter was 24.5 mm (SD: 3.1) and 81% of patients had smaller glenoid dimensions compared to the baseplate itself. PSI produced significantly longer superior (44.7 vs. 30.7 mm; P < 0.001) and inferior (43.0 vs. 31 mm; P < 0.001) mean screw lengths, as compared to CI. A greater proportion of maximal screw lengths for the given rTSA construct (48 mm) were observed in the PSI group (71.9% vs. 11.9% superior, 59.4% vs. 11.9% inferior). Operative duration was not statistically significantly different between the PSI and CI groups (150 min vs. 169 min, respectively; P = 0.229). No patients had radiographic loosening of the glenoid component with an average of 2-year follow-up. CONCLUSION: PSI facilitates longer superior and inferior screw placement in the fixation of the glenoid component for rTSA. With sufficient training, PSI can be designed and implemented by surgeons themselves.


Subject(s)
Arthroplasty, Replacement, Shoulder , Bone Screws , Shoulder Joint , Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Glenoid Cavity/surgery , Retrospective Studies , Printing, Three-Dimensional
2.
JSES Int ; 5(4): 714-721, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34223420

ABSTRACT

BACKGROUND: Reverse shoulder arthroplasty is becoming an increasingly common surgical procedure in Hong Kong, as well as in many other countries worldwide. The aim of this study is to describe the glenoid anatomy in the Southern Chinese population. We are interested to know whether commercially available glenoid implants are suitable for this population and whether there are any steps or precautions we can take during surgery to optimize the clinical outcome for these patients. METHOD: A total of 244 shoulders of Southern Chinese patients were analyzed using 2-dimensional computed tomography, formatted to align along the scapular axis. The anatomic parameters analyzed included the shape, axial configuration, maximum width, maximum height, version, and presence of bone defect. RESULTS: In our study, 76.6% of glenoids were pear-shaped, 23.0% were elliptical, and only 0.4% were inverted pear in shape. Of all glenoids, 95.1% of glenoids had posterior-prominent axial configuration, whereas 4.9% had neutral axial configuration. The mean maximum glenoid height for both genders was 33.8 mm, whereas the mean maximum glenoid height was 32.2 mm for women and 36.6 mm for men. The mean maximum glenoid width for both genders was 25.8 mm, whereas the mean maximum glenoid width was 24.8 mm for women and 27.3 mm for men. The differences in measurements between genders were statistically significant. Of all glenoids, 46.3% of the glenoids were retroverted, whereas 53.7% of the glenoids were anteverted. The mean version for both genders was 0.77 degrees anteversion. The mean version was 1.16 degrees anteversion for women and 0.10 degrees anteversion for men. Of the 244 glenoids, 4 had bone defects. In our study, 39.8% of patients had mean maximum glenoid widths that were less than 25 mm, which is the smallest size available for most conventional glenoid baseplates. CONCLUSION: A significant portion of the Southern Chinese population has glenoid widths that are smaller than the smallest commercially available glenoid baseplates. Understanding the glenoid anatomy is crucial in the case of reverse shoulder arthroplasty, as it has significant implications in implant design, operative planning, and surgical outcomes.

3.
Foot Ankle Clin ; 24(3): 515-531, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31371001

ABSTRACT

Haglund syndrome is a triad of posterosuperior calcaneal prominence (Haglund deformity), retrocalcaneal bursitis, and insertional Achilles tendinopathy. The sources of pain include the posterior calcaneal wall cartilage, retrocalcaneal and subcutaneous adventitial bursa, and the Achilles tendon. Resection of the posterosuperior calcaneal tubercle, bursectomy, excision of the Achilles tendon pathology, reattachment of the Achilles tendon, gastrocnemius aponeurotic recession, and flexor hallucis longus transfer have been proposed as surgical treatment options. All of them can be performed endoscopically or under minimally invasive approaches.


Subject(s)
Achilles Tendon/surgery , Bursitis/surgery , Calcaneus/abnormalities , Endoscopy/methods , Foot Deformities/surgery , Foot Diseases/surgery , Minimally Invasive Surgical Procedures/methods , Tendinopathy/surgery , Humans , Syndrome
4.
Unfallchirurg ; 122(4): 278-285, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30887060

ABSTRACT

There are numerous orthopaedic applications of three-dimensional (3D) printing for the pelvis and acetabulum. The authors reviewed recently published articles and summarized their experience. 3D printed anatomical models are particularly useful in pelvic and acetabular fracture surgery for planning, implant templating and for anatomical assessment of pathologies such as CAM-type femoroacetabular impingement and rare deformities. Custom-made metal 3D printed patient-specific implants and instruments are increasingly being studied for pelvic oncologic resection and reconstruction of resected defects as well as for revision hip arthroplasties with favourable results. This article also discusses cost-effectiveness considerations when preparing pelvic 3D printed models from a hospital 3D printing centre.


Subject(s)
Musculoskeletal Diseases/surgery , Musculoskeletal System/surgery , Pelvic Bones/surgery , Printing, Three-Dimensional , Acetabulum/surgery , Humans , Models, Anatomic , Musculoskeletal System/injuries , Prostheses and Implants
5.
Arthrosc Tech ; 7(2): e71-e76, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29552472

ABSTRACT

Identification of the correct source of symptoms is the key in formulating the correct treatment plan for heel pain after calcaneal malunion. Calcaneofibular and posterior ankle impingements can occur due to malunion of a joint depressed-type calcaneal fracture. The purpose of this Technical Note is to report the technical details of posterior and lateral decompression through the posteromedial and posterolateral portals using posterior ankle endoscopy.

6.
Arch Trauma Res ; 3(4): e18178, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25685749

ABSTRACT

INTRODUCTION: Unilateral anterior shoulder dislocation is one of the most common problems encountered in orthopedic practice. However, simultaneous bilateral anterior dislocation of the shoulders is quite rare. CASE PRESENTATION: We report a case of a 75-year-old woman presented with simultaneous bilateral anterior shoulder dislocation following a trauma, complicated with a traction injury to the posterior cord of the brachial plexus. CONCLUSIONS: Bilateral anterior shoulder dislocation is very rare. The excessive traction force during closed reduction may lead to nerve palsy. Clear documentation of neurovascular status and adequate imaging before and after a reduction should be performed.

SELECTION OF CITATIONS
SEARCH DETAIL
...