Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasound Int Open ; 1(2): E67-71, 2015 Nov.
Article in English | MEDLINE | ID: mdl-27689156

ABSTRACT

AIM: The actual occurrence of spontaneous plaque rupture in mice has been a matter of debate. We report on an in vivo observation of the actual event of possible plaque disruption in a living ApoE(-/-) mouse. METHODS AND RESULTS: During live contrast-enhanced ultrasonography of a 50-week-old ApoE(-/-) male mouse, symptoms suggesting plaque disruption in the brachiocephalic artery were observed. Histological analysis confirmed the presence of advanced atherosclerotic lesions with dissections and intraplaque hemorrhage in the affected brachiocephalic trunk, pointing towards plaque rupture as the cause of the observed event. However, we did not detect a luminal thrombus or cap rupture, which is a key criterion for plaque rupture in human atherosclerosis. CONCLUSION: This study reports the real-time occurrence of a possible plaque rupture in a living ApoE(-/-) mouse.

2.
Biotechnol Bioeng ; 112(1): 220-7, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25088405

ABSTRACT

The use of stem cells for the repair of damaged cardiac tissue after a myocardial infarction holds great promise. However, a common finding in experimental studies is the low number of cells delivered at the area at risk. To improve the delivery, we are currently investigating a novel delivery platform in which stem cells are conjugated with targeted microbubbles, creating echogenic complexes dubbed StemBells. These StemBells vibrate in response to incoming ultrasound waves making them susceptible to acoustic radiation force. The acoustic force can then be employed to propel circulating StemBells from the centerline of the vessel to the wall, facilitating localized stem cell delivery. In this study, we investigate the feasibility of manipulating StemBells acoustically in vivo after injection using a chicken embryo model. Bare stem cells or unsaturated stem cells (<5 bubbles/cell) do not respond to ultrasound application (1 MHz, peak negative acoustical pressure P_ = 200 kPa, 10% duty cycle). However, stem cells which are fully saturated with targeted microbubbles (>30 bubbles/cell) can be propelled toward and arrested at the vessel wall. The mean translational velocities measured are 61 and 177 µm/s for P- = 200 and 450 kPa, respectively. This technique therefore offers potential for enhanced and well-controlled stem cell delivery for improved cardiac repair after a myocardial infarction.


Subject(s)
Mesenchymal Stem Cell Transplantation , Microbubbles , Microscopy/methods , Stem Cells/cytology , Acoustics , Animals , Cells, Cultured , Chick Embryo , Chickens , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...